Accuracy of plasma sample methods for determination of glomerular filtration rate with 99mTc-DTPA

被引:36
|
作者
Itoh, K
Tsushima, S
Tsukamoto, E
Tamaki, N
机构
[1] JR Sapporo Gen Hosp, Dept Radiol, Chuo Ku, Sapporo, Hokkaido, Japan
[2] JR Sapporo Gen Hosp, Dept Internal Med, Chuo Ku, Sapporo, Hokkaido, Japan
[3] Hokkaido Univ, Sch Med, Dept Nucl Med, Sapporo, Hokkaido 060, Japan
关键词
glomerular filtration rate; plasma sample method; Tc-99m-DTPA;
D O I
10.1007/BF02995290
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The plasma sample method following a single injection of radioactive markers has been proved to be simple and accurate for the determination of glomerular filtration rate (GFR) in clinical practice. The aim of this study was to assess clinical accuracy of single-, two- and multi-sample methods. Methods: The study was performed on 50 patients with various degrees of renal dysfunction (29 males and 21 females; aged 27 to 90 years). As a reference the true GFR (GFRt) was determined by means of the two-compartment model curve fitting 10 plasma samples following a single-injection of Tc-99m-DTPA. The GFRt was compared to the GFR estimated by the Christensen and Groth's single-sample (GFRcg), two-sample (GFR(2)s) and multi-sample (GFRm) between 75 and 300 min after the injection. The GFRs by two- and multi-sample methods were determined with the slope and intercept algorithm and its overestimation was corrected by Brochner-Mortensen's formula. Results: In 49 patients with GFR between 12 and 169 ml/min/1.73 m(2), the standard deviation of difference (95% limits of agreement) between GFRt and GFRcg at 180 min was 6.513 ml/min/173 m(2) (-16.5 similar to 9.5 ml/min/1.73 m(2)), which was somewhat closer than 7.311 ml/min/1.73 m(2) (-12.5 similar to 16.5 ml/min/1.73 m(2)) in GFR(2)s in slow clearance phase at 120 min and 240 min. However, the single-sample method tended to show some scattering in GFR below 30 and above 140 ml/min/1.73 m(2). On the contrary, the 2-sample method tended to be scattered in GFR above 120 ml/min/1.73 m(2). Conclusion: In view of its accuracy and technical simplicity, the single-sample method is first choice in a routine practice. The two-sample method is essential of choice for a patient in whom the GFR is expected to be below 30 ml/min/1.73 m(2). These two methods may be chosen selectively in dependence on the preserved renal function which is expected at time of the test.
引用
收藏
页码:39 / 44
页数:6
相关论文
共 50 条
  • [31] Standardization of normal 99mTc-L,L EC clearance value in Indian population in comparison with two plasma sample method of glomerular filtration rate (GFR) estimation with 99mTc-DTPA
    Shamim, Ahmed Shamim
    Kumar, Naresh
    Arora, Geetanjali
    Tripathi, Madhavi
    Kumar, Rakesh
    Bal, Chandrasekhar
    JOURNAL OF NUCLEAR MEDICINE, 2022, 63
  • [32] The correlation between effective renal plasma flow (ERPF) and glomerular filtration rate (GFR) with renal scintigraphy 99mTc-DTPA study
    Ratnasari, D.
    Nazir, F.
    Toresano, L. O. H. Z.
    Pawiro, S. A.
    Soejoko, D. S.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [33] Comparison of 99mTc-DTPA and 51Cr-EDTA for glomerular filtration rate measurement with the continuous infusion method
    Balouzet, Clara
    Michon-Colin, Arthur
    Dupont, Lea
    Vidal-Petiot, Emmanuelle
    Prot-Bertoye, Caroline
    Baron, Stephanie
    Ayari, Hamza
    Cohen, Raphal
    Houillier, Pascal
    Smadja, Corinne
    Flamant, Martin
    Courbebaisse, Marie
    JOURNAL OF NEPHROLOGY, 2023, 36 (09) : 2457 - 2465
  • [34] Comparison of 99mTc-DTPA and 51Cr-EDTA for glomerular filtration rate measurement with the continuous infusion method
    Clara Balouzet
    Arthur Michon-Colin
    Léa Dupont
    Emmanuelle Vidal-Petiot
    Caroline Prot-Bertoye
    Stéphanie Baron
    Hamza Ayari
    Raphaël Cohen
    Pascal Houillier
    Corinne Smadja
    Martin Flamant
    Marie Courbebaisse
    Journal of Nephrology, 2023, 36 : 2457 - 2465
  • [35] Effect of region of interest selection and uptake measurement on glomerular filtration rate measured by 99mTc-DTPA scintigraphy in dogs
    Kampa, N
    Wennstrom, U
    Lord, P
    Twardock, R
    Maripuu, E
    Eksell, P
    Fredriksson, SO
    VETERINARY RADIOLOGY & ULTRASOUND, 2002, 43 (04) : 383 - 391
  • [36] Measurement of glomerular filtration rate by the 99mTc-DTPA renogram is less precise than measured and predicted creatinine clearance
    De Santo, NG
    Anastasio, P
    Cirillo, M
    Santoro, D
    Spitali, L
    Mansi, L
    Celentano, L
    Capodicasa, D
    Cirillo, E
    Del Vecchio, E
    Pascale, C
    Capasso, G
    NEPHRON, 1999, 81 (02): : 136 - 140
  • [37] The gamma camera as an absolute measurement device:: Determination of glomerular filtration rate in 99mTc-DTPA renography using a dual head gamma camera
    Carlsen, O
    NUCLEAR MEDICINE COMMUNICATIONS, 2004, 25 (10) : 1021 - 1029
  • [38] Glomerular filtration rate measured by 99mTc-DTPA Gates method is not significantly affected by the premature or delayed initiation of image acquisition
    Ma, Guangyu
    Shao, Mingzhe
    Xu, Baixuan
    Tian, Jiahe
    Chen, Yingmao
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (06) : 1103 - 1109
  • [39] Comparison of 99mTc-DTPA and 51Cr-EDTA for glomerular filtration rate measurement with a bolus followed by a continuous infusion
    Balouzet, Clara
    Dupont, Lea
    Ayari, Hamza
    Cohen, Raphael
    Schurder, Juliet
    Baron, Stephanie
    Houillier, Pascal
    Vidal-Petiot, Emmanuelle
    Smadja, Corinne
    Courbebaisse, Marie
    ACTA PHYSIOLOGICA, 2019, 227
  • [40] Measurement of Glomerular Filtration Rate Estimated by Schwartz Formula in Children with Chronic Kidney Disease and Comparison with 99mTc-DTPA Clearance
    Zhang, J.
    Cao, Q.
    Xu, H.
    PEDIATRIC NEPHROLOGY, 2010, 25 (09) : 1936 - 1936