Accuracy of plasma sample methods for determination of glomerular filtration rate with 99mTc-DTPA

被引:36
|
作者
Itoh, K
Tsushima, S
Tsukamoto, E
Tamaki, N
机构
[1] JR Sapporo Gen Hosp, Dept Radiol, Chuo Ku, Sapporo, Hokkaido, Japan
[2] JR Sapporo Gen Hosp, Dept Internal Med, Chuo Ku, Sapporo, Hokkaido, Japan
[3] Hokkaido Univ, Sch Med, Dept Nucl Med, Sapporo, Hokkaido 060, Japan
关键词
glomerular filtration rate; plasma sample method; Tc-99m-DTPA;
D O I
10.1007/BF02995290
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The plasma sample method following a single injection of radioactive markers has been proved to be simple and accurate for the determination of glomerular filtration rate (GFR) in clinical practice. The aim of this study was to assess clinical accuracy of single-, two- and multi-sample methods. Methods: The study was performed on 50 patients with various degrees of renal dysfunction (29 males and 21 females; aged 27 to 90 years). As a reference the true GFR (GFRt) was determined by means of the two-compartment model curve fitting 10 plasma samples following a single-injection of Tc-99m-DTPA. The GFRt was compared to the GFR estimated by the Christensen and Groth's single-sample (GFRcg), two-sample (GFR(2)s) and multi-sample (GFRm) between 75 and 300 min after the injection. The GFRs by two- and multi-sample methods were determined with the slope and intercept algorithm and its overestimation was corrected by Brochner-Mortensen's formula. Results: In 49 patients with GFR between 12 and 169 ml/min/1.73 m(2), the standard deviation of difference (95% limits of agreement) between GFRt and GFRcg at 180 min was 6.513 ml/min/173 m(2) (-16.5 similar to 9.5 ml/min/1.73 m(2)), which was somewhat closer than 7.311 ml/min/1.73 m(2) (-12.5 similar to 16.5 ml/min/1.73 m(2)) in GFR(2)s in slow clearance phase at 120 min and 240 min. However, the single-sample method tended to show some scattering in GFR below 30 and above 140 ml/min/1.73 m(2). On the contrary, the 2-sample method tended to be scattered in GFR above 120 ml/min/1.73 m(2). Conclusion: In view of its accuracy and technical simplicity, the single-sample method is first choice in a routine practice. The two-sample method is essential of choice for a patient in whom the GFR is expected to be below 30 ml/min/1.73 m(2). These two methods may be chosen selectively in dependence on the preserved renal function which is expected at time of the test.
引用
收藏
页码:39 / 44
页数:6
相关论文
共 50 条
  • [21] Determination of the renal functional reserve with 99mTc-DTPA with two serum samples glomerular filtration rate in Behcet Disease.
    Gul, S. S.
    Hasbek, Z.
    Erselcan, T.
    Akyol, M.
    Turgut, B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S575 - S576
  • [22] Simultaneous glomerular filtration rate determination using inulin, iohexol, and 99mTc-DTPA demonstrates the need for customized measurement protocols
    White, Christine A.
    Akbari, Ayub
    Allen, Celine
    Day, Andrew G.
    Norman, Patrick A.
    Holland, David
    Adams, Michael A.
    Knoll, Greg A.
    KIDNEY INTERNATIONAL, 2021, 99 (04) : 957 - 966
  • [23] Deep regression using 99mTc-DTPA dynamic renal imaging for automatic calculation of the glomerular filtration rate
    Pi, Yong
    Zhao, Zhen
    Yang, Pei
    Cheng, Junjun
    Jiang, Lisha
    Wei, Jianan
    Chen, Xiaolei
    Cai, Huawei
    Yi, Zhang
    EUROPEAN RADIOLOGY, 2023, 33 (01) : 34 - 42
  • [24] Fully Automatic Region of Interest Selection in Glomerular Filtration Rate Estimation from 99mTc-DTPA Renogram
    Lin, Kun-Ju
    Huang, Jia-Yann
    Chen, Yung-Sheng
    JOURNAL OF DIGITAL IMAGING, 2011, 24 (06) : 1010 - 1023
  • [25] Fully Automatic Region of Interest Selection in Glomerular Filtration Rate Estimation from 99mTc-DTPA Renogram
    Kun-Ju Lin
    Jia-Yann Huang
    Yung-Sheng Chen
    Journal of Digital Imaging, 2011, 24 : 1010 - 1023
  • [26] Deep regression using 99mTc-DTPA dynamic renal imaging for automatic calculation of the glomerular filtration rate
    Yong Pi
    Zhen Zhao
    Pei Yang
    Junjun Cheng
    Lisha Jiang
    Jianan Wei
    Xiaolei Chen
    Huawei Cai
    Zhang Yi
    European Radiology, 2023, 33 : 34 - 42
  • [27] Glomerular filtration rate estimated from the uptake phase of 99mTc-DTPA renography in chronic renal failure
    Petersen, LJ
    Petersen, JR
    Talleruphuus, U
    Moller, ML
    Ladefoged, SD
    Mehlsen, J
    Jensen, H&Aelig
    不详
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1999, 14 (07) : 1673 - 1678
  • [28] Repeatability of glomerular filtration rate studies performed using 99mTc-DTPA in a population including cancer patients
    Berndorfler, Bianca D.
    Holness, Jennifer L.
    Warwick, James M.
    NUCLEAR MEDICINE COMMUNICATIONS, 2021, 42 (03) : 261 - 266
  • [29] The 99mTc-DTPA Urinary Clearance Method May Be Preferable to the Plasma Disappearance Method for Assessing Glomerular Filtration Rate in Diabetic Nephropathy
    Huang, Shih-Han S.
    Eliasziw, Misha
    Spence, J. David
    Filler, Guido
    Vezina, William C.
    Churchill, David N.
    Cattran, Daniel C.
    Richardson, Bonnie
    House, Andrew A.
    NEPHRON CLINICAL PRACTICE, 2014, 128 (3-4): : 367 - 372
  • [30] Estimating glomerular filtration rate in oncology patients receiving Cisplatin chemotherapy: Predicted creatinine clearance against 99mTc-DTPA methods
    Sahab, Sharifah Khaidah Syed
    Manap, Mahayuddin
    Hamzah, Fadzilah
    10TH INTERNATIONAL SEMINAR ON MEDICAL PHYSICS & 1ST AMDI INTERNATIONAL ONCOLOGY SYMPOSIUM, 2017, 851