Accuracy of plasma sample methods for determination of glomerular filtration rate with 99mTc-DTPA

被引:36
|
作者
Itoh, K
Tsushima, S
Tsukamoto, E
Tamaki, N
机构
[1] JR Sapporo Gen Hosp, Dept Radiol, Chuo Ku, Sapporo, Hokkaido, Japan
[2] JR Sapporo Gen Hosp, Dept Internal Med, Chuo Ku, Sapporo, Hokkaido, Japan
[3] Hokkaido Univ, Sch Med, Dept Nucl Med, Sapporo, Hokkaido 060, Japan
关键词
glomerular filtration rate; plasma sample method; Tc-99m-DTPA;
D O I
10.1007/BF02995290
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The plasma sample method following a single injection of radioactive markers has been proved to be simple and accurate for the determination of glomerular filtration rate (GFR) in clinical practice. The aim of this study was to assess clinical accuracy of single-, two- and multi-sample methods. Methods: The study was performed on 50 patients with various degrees of renal dysfunction (29 males and 21 females; aged 27 to 90 years). As a reference the true GFR (GFRt) was determined by means of the two-compartment model curve fitting 10 plasma samples following a single-injection of Tc-99m-DTPA. The GFRt was compared to the GFR estimated by the Christensen and Groth's single-sample (GFRcg), two-sample (GFR(2)s) and multi-sample (GFRm) between 75 and 300 min after the injection. The GFRs by two- and multi-sample methods were determined with the slope and intercept algorithm and its overestimation was corrected by Brochner-Mortensen's formula. Results: In 49 patients with GFR between 12 and 169 ml/min/1.73 m(2), the standard deviation of difference (95% limits of agreement) between GFRt and GFRcg at 180 min was 6.513 ml/min/173 m(2) (-16.5 similar to 9.5 ml/min/1.73 m(2)), which was somewhat closer than 7.311 ml/min/1.73 m(2) (-12.5 similar to 16.5 ml/min/1.73 m(2)) in GFR(2)s in slow clearance phase at 120 min and 240 min. However, the single-sample method tended to show some scattering in GFR below 30 and above 140 ml/min/1.73 m(2). On the contrary, the 2-sample method tended to be scattered in GFR above 120 ml/min/1.73 m(2). Conclusion: In view of its accuracy and technical simplicity, the single-sample method is first choice in a routine practice. The two-sample method is essential of choice for a patient in whom the GFR is expected to be below 30 ml/min/1.73 m(2). These two methods may be chosen selectively in dependence on the preserved renal function which is expected at time of the test.
引用
收藏
页码:39 / 44
页数:6
相关论文
共 50 条
  • [1] Accuracy of plasma sample methods for determination of glomerular filtration rate with99mTc-DTPA
    Kazuo Itoh
    Satoshi Tsushima
    Eriko Tsukamoto
    Nagara Tamaki
    Annals of Nuclear Medicine, 2002, 16 : 39 - 44
  • [2] Reappraisal of single-sample and gamma camera methods for determination of the glomerular filtration rate with 99mTc-DTPA
    Itoh, K
    Tsushima, S
    Tsukamoto, E
    Tamaki, N
    ANNALS OF NUCLEAR MEDICINE, 2000, 14 (03) : 143 - 150
  • [3] Nephrotoxicity of CDDP Assessed Estimating Glomerular Filtration Rate With 99mTc-DTPA Plasma Sample Method
    Fatima, Nosheen
    Niaz, Khalid
    Maseeh-Uz-Zaman
    Kamal, Shahid
    Hameed, Abid
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2010, 20 (02): : 98 - 101
  • [4] Comparison of different simplified methods to determinate Glomerular Filtration Rate with 99mTc-DTPA
    Hernandez Fructuoso, M. A.
    Romero Herrera, J. E.
    Santos Montero, B.
    Franco Monterroso, C. G.
    Ruiz Llama, S.
    Castell Conesa, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S538 - S538
  • [5] 99mTc-DTPA scintigraphy for glomerular filtration rate determination in single kidney children
    Caroli, P.
    Lopci, E.
    Pettinato, C.
    Civollani, S.
    Ambrosini, V.
    La Scola, C.
    Lega, M.
    Cicoria, G.
    Montini, G.
    Fanti, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S405 - S406
  • [6] Comparison of 99mTc-DTPA One-sample Glomerular Filtration Rate Determination (EANM Guideline) with Nonradionuclide Methods in Adolescents
    Koranda, P.
    Flogelova, H.
    Navratil, R.
    Stefanickova, L.
    Quinn, L.
    Kaminek, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S29 - S29
  • [7] THE EVALUATION OF 99MTC-DTPA RENOGRAPHY ON THE MEASUREMENT OF GLOMERULAR FILTRATION RATE
    Ma, Yingchun
    Zuo, Li
    Wang, Mei
    Wang, Haiyan
    NEPHROLOGY, 2005, 10 : A144 - A144
  • [8] SIMPLIFIED METHODS FOR DETERMINING GLOMERULAR FILTRATION RATE (GFR) USING PLASMA CLEARANCE (PC) OF IOHEXOL OR 99mTc-DTPA (DTPA) † 1664
    Arundhati S Kale
    Eileen D Brewer
    Daryl J Murry
    Warren H Moore
    Pediatric Research, 1997, 41 (Suppl 4) : 280 - 280
  • [9] A comparison of the plasma disappearance of iohexol and 99mTc-DTPA for the measurement of glomerular filtration rate (GFR) in diabetes
    Houlihan, C
    Scott, A
    Jenkins, M
    Parkin, D
    Osicka, T
    Jerums, G
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1999, 29 (05): : 693 - 700
  • [10] Modified Schwartz formula and 99mTc-DTPA plasma clearance methods to calculate glomerular filtration rate in critically ill children
    Rohit Bhowmick
    Ramachandran Rameshkumar
    Madhusudhanan Ponnusamy
    Vishnukumar Rajaraman
    Muthu Chidambaram
    Abraar Sheriff
    Subramanian Mahadevan
    Pediatric Nephrology, 2022, 37 : 899 - 906