The objective of this study was to develop a method to monitor the microbial quality of treated drinking water at the tap utilizing point-of-use filter systems that are placed in water vending machines. Such vending machines have high-volume water throughput and allow for an evaluation of the occurrence of human enteric pathogens and fecal indicator bacteria in tap water over extended time periods. Seeded experiments, using Escherichia coli and bacteriophage MS-2, were performed on (i) new filters, (ii) artificially aged filters, and (iii) filters that had been used in the field (naturally aged filters) to evaluate the efficiency of recovery of these organisms from the three-component filter set (30 mu m, 5 mu m, solid block carbon (SBC)) by evaluating each filter independently. SBC filters had the highest recovery of the organisms, averaging recovery of 27% and 5% for E coli and MS-2, respectively. Subsequently, tap water supplies were monitored in vending machines throughout Southern Arizona using SBC filters as a monitoring tool. A total of 48 filters from 41 unique site locations were surveyed for the presence of total coliforms, E. coli, enterococci, Cryptosporidium, enteroviruses, and noroviruses. Organisms were detected following the passage of large volumes of water ranging from 1000 to 17 000 L through the filters. Out of 48 SBC filters 54.2% were positive for at least one organism. The number of filters positive for total coliforms, E coli, enterococci, and enterovirus was 13, 5,19, and 3, respectively, corresponding to 27.1%, 10.4%, 39.6%, and 6.3% of the total filters. No filters were positive for noroviruses or Cryptosporidium. These results suggest that the SBC filter can be used to monitor large volumes of treated drinking water and detect the incidence of indicators and pathogens that may be present at low concentrations. These data show that post-treated water often contains water quality indicator and pathogenic organisms at the tap, and therefore, monitoring with this method would be beneficial to the community as it allows for an assessment of exposure to pathogens and associative risks. This monitoring tool will also aid in the tracking of outbreaks and the determination
引用
收藏
页码:1425 / 1429
页数:5
相关论文
共 50 条
  • [1] Microplastic Removal from Drinking Water Using Point-of-Use Devices
    Cherian, Ashlyn G.
    Liu, Zeyuan
    McKie, Michael J.
    Almuhtaram, Husein
    Andrews, Robert C.
    POLYMERS, 2023, 15 (06)
  • [2] Performance of point-of-use devices to remove manganese from drinking water
    Carriere, Annie
    Brouillon, Manon
    Sauve, Sebastien
    Bouchard, Maryse F.
    Barbeau, Benoit
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2011, 46 (06): : 601 - 607
  • [3] The Case for Point-of-Use Reverse Osmosis for Tackling Lead Drinking Water Contamination
    Mitchell, Emily
    Nandakumar, Vaishnavi Koyilath
    Park, Shinyoung
    Lall, Upmanu
    ACS ES&T WATER, 2024,
  • [4] Point-of-use filtration units as drinking water distribution system sentinels
    Bai, Weiliang
    Xu, Ruizhe
    Podar, Mircea
    Swift, Cynthia M.
    Saleh, Navid B.
    Loffler, Frank E.
    Alvarez, Pedro J. J.
    Kumar, Manish
    NPJ CLEAN WATER, 2024, 7 (01):
  • [5] Assessing arsenic exposure in households using bottled water or point-of-use treatment systems to mitigate well water contamination
    Smith, Andrew E.
    Lincoln, Rebecca A.
    Paulu, Chris
    Simones, Thomas L.
    Caldwell, Kathleen L.
    Jones, Robert L.
    Backer, Lorraine C.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2016, 544 : 701 - 710
  • [6] Evaluation of point-of-use drinking water treatment systems' performance and problems
    Fahiminia, Mohammad
    Mosaferi, Mohammad
    Taadi, Reza A.
    Pourakbar, Mojtaba
    DESALINATION AND WATER TREATMENT, 2014, 52 (10-12) : 1855 - 1864
  • [7] Fouling in gravity driven Point-of-Use drinking water treatment systems
    Chawla, C.
    Zwijnenburg, A.
    Kemperman, A. J. B.
    Nijmeijer, K.
    CHEMICAL ENGINEERING JOURNAL, 2017, 319 : 89 - 97
  • [8] Control of health risks in drinking water through point-of-use systems
    Liu RuiPing
    Qu JiuHui
    CHINESE SCIENCE BULLETIN, 2009, 54 (12): : 1996 - 2001
  • [9] Control of health risks in drinking water through point-of-use systems
    LIU RuiPing & QU JiuHui Research Center for Eco-Environmental Sciences
    Science Bulletin, 2009, (12) : 1996 - 2001
  • [10] Assessing the Effectiveness of Point-of-Use Residential Drinking Water Filters for Perfluoroalkyl Substances (PFASs)
    Herkert, Nicholas J.
    Merrill, John
    Peters, Cara
    Bollinger, David
    Zhang, Sharon
    Hoffman, Kate
    Ferguson, P. Lee
    Knappe, Detlef R. U.
    Stapleton, Heather M.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY LETTERS, 2020, 7 (03) : 178 - 184