Point-of-Use Drinking Water Devices for Assessing Microbial Contamination in Finished Water and Distribution Systems

被引:11
|
作者
Miles, Syreeta L. [1 ]
Gerba, Charles P. [1 ]
Pepper, Ian I. [1 ]
Reynolds, Kelly A. [2 ]
机构
[1] Univ Arizona, Soil Water & Environm Sci Dept, Tucson, AZ 85719 USA
[2] Univ Arizona, Zuckerman Coll Publ Hlth, Tucson, AZ 85724 USA
基金
美国国家科学基金会;
关键词
RISK-ASSESSMENT; UNITED-STATES; DISEASE; VIRUS;
D O I
10.1021/es801482p
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The objective of this study was to develop a method to monitor the microbial quality of treated drinking water at the tap utilizing point-of-use filter systems that are placed in water vending machines. Such vending machines have high-volume water throughput and allow for an evaluation of the occurrence of human enteric pathogens and fecal indicator bacteria in tap water over extended time periods. Seeded experiments, using Escherichia coli and bacteriophage MS-2, were performed on (i) new filters, (ii) artificially aged filters, and (iii) filters that had been used in the field (naturally aged filters) to evaluate the efficiency of recovery of these organisms from the three-component filter set (30 mu m, 5 mu m, solid block carbon (SBC)) by evaluating each filter independently. SBC filters had the highest recovery of the organisms, averaging recovery of 27% and 5% for E coli and MS-2, respectively. Subsequently, tap water supplies were monitored in vending machines throughout Southern Arizona using SBC filters as a monitoring tool. A total of 48 filters from 41 unique site locations were surveyed for the presence of total coliforms, E. coli, enterococci, Cryptosporidium, enteroviruses, and noroviruses. Organisms were detected following the passage of large volumes of water ranging from 1000 to 17 000 L through the filters. Out of 48 SBC filters 54.2% were positive for at least one organism. The number of filters positive for total coliforms, E coli, enterococci, and enterovirus was 13, 5,19, and 3, respectively, corresponding to 27.1%, 10.4%, 39.6%, and 6.3% of the total filters. No filters were positive for noroviruses or Cryptosporidium. These results suggest that the SBC filter can be used to monitor large volumes of treated drinking water and detect the incidence of indicators and pathogens that may be present at low concentrations. These data show that post-treated water often contains water quality indicator and pathogenic organisms at the tap, and therefore, monitoring with this method would be beneficial to the community as it allows for an assessment of exposure to pathogens and associative risks. This monitoring tool will also aid in the tracking of outbreaks and the determination
引用
收藏
页码:1425 / 1429
页数:5
相关论文
共 50 条
  • [41] POINT-OF-USE CONTAMINATION CONTROL OF ULTRAPURE DEIONIZED WATER FOR SEMICONDUCTOR PROCESSING.
    Siegmann, Robert P.
    Microcontamination, 1987, 5 (03): : 24 - 26
  • [42] Contamination of drinking water between source and point-of-use in rural households of South Africa and Zimbabwe: implications for monitoring the Millennium Development Goal for water
    Gundry, Stephen W.
    Wright, James A.
    Conroy, Ronan
    Du Preez, Martella
    Genthe, Bettina
    Moyo, Sibonginkosi
    Mutisi, Charles
    Ndamba, Jerikias
    Potgieter, Natasha
    WATER PRACTICE AND TECHNOLOGY, 2006, 1 (02):
  • [43] Point-of-use purification for ultrapure water
    不详
    FILTRATION + SEPARATION, 2007, 44 (09) : 11 - 11
  • [44] UV-LED-incorporated showerhead for point-of-use disinfection of drinking water
    Song, Jack Jia Xin
    Oguma, Kumiko
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2024, 12 (06):
  • [45] Pathogen Inactivation in Drinking Water: A Point-of-Use Microscale Reactor with Ultraviolet Irradiation
    Nguyen, Christine C.
    Mohamed, Omar M.
    Coblyn, Matthew Y.
    Jovanovic, Goran N.
    Navab-Daneshmand, Tala
    ENVIRONMENTAL ENGINEERING SCIENCE, 2022, 39 (07) : 598 - 605
  • [46] Adoption of Point-of-Use Chlorination for Household Drinking Water Treatment: A Systematic Review
    Crider, Yoshika S.
    Tsuchiya, Miki
    Mukundwa, Magnifique
    Ray, Isha
    Pickering, Amy J.
    ENVIRONMENTAL HEALTH PERSPECTIVES, 2023, 131 (01)
  • [47] Performance of microbiological control by a point-of-use filter system for drinking water purification
    SU FengyiLUO MingfangZHANG FeiLI PengLOU KaiXING Xinhui Department of Chemical EngineeringTsinghua UniversityBeijing China College of Chemistry and Chemical EngineeringGraduate University of Chinese Academy of SciencesBeijing China Institute of MicrobiologyXinjiang Academy of Agricultural SciencesUrumqi China
    Journal of Environmental Sciences, 2009, (09) : 1237 - 1246
  • [48] Challenges in Designing Electrochemical Disinfection Systems for Reducing Microbial Contamination in Drinking Water Distribution Networks
    Ferro, Sergio
    WATER, 2025, 17 (05)
  • [50] Performance of microbiological control by a point-of-use filter system for drinking water purification
    Su Fengyi
    Luo Mingfang
    Zhang Fei
    Li Peng
    Lou Kai
    Xing Xinhui
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2009, 21 (09) : 1237 - 1246