Point-of-Use Drinking Water Devices for Assessing Microbial Contamination in Finished Water and Distribution Systems

被引:11
|
作者
Miles, Syreeta L. [1 ]
Gerba, Charles P. [1 ]
Pepper, Ian I. [1 ]
Reynolds, Kelly A. [2 ]
机构
[1] Univ Arizona, Soil Water & Environm Sci Dept, Tucson, AZ 85719 USA
[2] Univ Arizona, Zuckerman Coll Publ Hlth, Tucson, AZ 85724 USA
基金
美国国家科学基金会;
关键词
RISK-ASSESSMENT; UNITED-STATES; DISEASE; VIRUS;
D O I
10.1021/es801482p
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The objective of this study was to develop a method to monitor the microbial quality of treated drinking water at the tap utilizing point-of-use filter systems that are placed in water vending machines. Such vending machines have high-volume water throughput and allow for an evaluation of the occurrence of human enteric pathogens and fecal indicator bacteria in tap water over extended time periods. Seeded experiments, using Escherichia coli and bacteriophage MS-2, were performed on (i) new filters, (ii) artificially aged filters, and (iii) filters that had been used in the field (naturally aged filters) to evaluate the efficiency of recovery of these organisms from the three-component filter set (30 mu m, 5 mu m, solid block carbon (SBC)) by evaluating each filter independently. SBC filters had the highest recovery of the organisms, averaging recovery of 27% and 5% for E coli and MS-2, respectively. Subsequently, tap water supplies were monitored in vending machines throughout Southern Arizona using SBC filters as a monitoring tool. A total of 48 filters from 41 unique site locations were surveyed for the presence of total coliforms, E. coli, enterococci, Cryptosporidium, enteroviruses, and noroviruses. Organisms were detected following the passage of large volumes of water ranging from 1000 to 17 000 L through the filters. Out of 48 SBC filters 54.2% were positive for at least one organism. The number of filters positive for total coliforms, E coli, enterococci, and enterovirus was 13, 5,19, and 3, respectively, corresponding to 27.1%, 10.4%, 39.6%, and 6.3% of the total filters. No filters were positive for noroviruses or Cryptosporidium. These results suggest that the SBC filter can be used to monitor large volumes of treated drinking water and detect the incidence of indicators and pathogens that may be present at low concentrations. These data show that post-treated water often contains water quality indicator and pathogenic organisms at the tap, and therefore, monitoring with this method would be beneficial to the community as it allows for an assessment of exposure to pathogens and associative risks. This monitoring tool will also aid in the tracking of outbreaks and the determination
引用
收藏
页码:1425 / 1429
页数:5
相关论文
共 50 条
  • [31] Point-of-use filtration method for the prevention of fungal contamination of hospital water
    Warris, A.
    Onken, A.
    Gaustad, P.
    Janssen, W.
    van der Lee, H.
    Verweij, P. E.
    Abrahamsen, T. G.
    JOURNAL OF HOSPITAL INFECTION, 2010, 76 (01) : 56 - 59
  • [32] Evaluating the Sustainability of Ceramic Filters for Point-of-Use Drinking Water Treatment
    Ren, Dianjun
    Colosi, Lisa M.
    Smith, James A.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2013, 47 (19) : 11206 - 11213
  • [33] Modeling Residual Chlorine Response to a Microbial Contamination Event in Drinking Water Distribution Systems
    Helbling, Damian E.
    VanBriesen, Jeanne M.
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2009, 135 (10): : 918 - 927
  • [34] Microbial Contamination of Drinking Water and Human Health from Community Water Systems
    Ashbolt N.J.
    Current Environmental Health Reports, 2015, 2 (1) : 95 - 106
  • [35] A novel and simple mixture as point-of-use water treatment agent to produce safe drinking water
    Islam, M. S.
    Ansaruzzaman, M.
    Mahmud, Z. H.
    Matin, M. A.
    Islam, M. S.
    Mallik, A. K.
    Neogi, S. B.
    Jahid, I. K.
    Endtz, H. P.
    Cravioto, A.
    Sack, D. A.
    TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 2014, 108 (05) : 290 - 296
  • [36] POINT-OF-USE AND POINT-OF-ENTRY WATER-TREATMENT SYSTEMS
    BELLEN, GE
    STEVENS, TG
    DRINKING WATER TREATMENT: SMALL SYSTEM ALTERNATIVES, 1989, : 143 - 158
  • [37] Cost-benefit analysis of point-of-use devices for health risks reduction from pathogens in drinking water
    Verhougstraete, Marc
    Reynolds, Kelly A.
    Pearce-Walker, Jennifer
    Gerba, Charles
    JOURNAL OF WATER AND HEALTH, 2020, 18 (06) : 968 - 982
  • [38] BACTERIAL-COLONIZATION OF POINT-OF-USE WATER-TREATMENT DEVICES
    GELDREICH, EE
    TAYLOR, RH
    BLANNON, JC
    REASONER, DJ
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 1985, 77 (02): : 72 - 80
  • [39] Assessing Participant Compliance With Point-of-Use Water Treatment: An Exploratory Investigation
    MacDonald, Morgan Callender
    Juran, Luke
    Srinivasan, Sekar
    Jose, Jincy
    Ali, Syed Imran
    Rajagopalan, Prema
    Hall, Kevin
    PUBLIC WORKS MANAGEMENT & POLICY, 2018, 23 (02) : 150 - 167
  • [40] A point-of-use drinking water quality dataset from fieldwork in Detroit, Michigan
    Schubert, Alyssa
    Harrison, Jacob
    Kent-Buchanan, Linda
    Bonds, Victor
    Mcelmurry, Shawn P.
    Love, Nancy G.
    SCIENTIFIC DATA, 2024, 11 (01)