Point-of-use filtration units as drinking water distribution system sentinels

被引:0
|
作者
Bai, Weiliang [1 ]
Xu, Ruizhe [1 ]
Podar, Mircea [2 ]
Swift, Cynthia M. [3 ]
Saleh, Navid B. [1 ]
Loffler, Frank E. [3 ,4 ,5 ]
Alvarez, Pedro J. J. [6 ]
Kumar, Manish [1 ,7 ]
机构
[1] Univ Texas Austin, Maseeh Dept Civil Architectural & Environm Engn, Austin, TX 78712 USA
[2] Oak Ridge Natl Lab, Biosci Div, Oak Ridge, TN 37830 USA
[3] Univ Tennessee, Dept Civil & Environm Engn, Knoxville, TN 37996 USA
[4] Univ Tennessee, Dept Biosyst Engn & Soil Sci, Knoxville, TN 37996 USA
[5] Univ Tennessee, Dept Microbiol, Knoxville, TN 37996 USA
[6] Rice Univ, Dept Civil & Environm Engn, Houston, TX USA
[7] Univ Texas Austin, McKetta Dept Chem Engn, Austin, TX 78712 USA
来源
NPJ CLEAN WATER | 2024年 / 7卷 / 01期
关键词
MYCOBACTERIUM-AVIUM; ECOLOGY; PREDICTION; TRANSPORT; EXPOSURE; SCALE; SPP;
D O I
10.1038/s41545-024-00346-1
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Municipal drinking water distribution systems (DWDSs) and associated premise plumbing (PP) systems are vulnerable to proliferation of opportunistic pathogens, even when chemical disinfection residuals are present, thus presenting a public health risk. Monitoring the structure of microbial communities of drinking water is challenging because of limited continuous access to faucets, pipes, and storage tanks. We propose a scalable household sampling method, which uses spent activated carbon and reverse osmosis (RO) membrane point-of-use (POU) filters to evaluate mid- to long-term occurrence of microorganisms in PP systems that are relevant to consumer exposure. As a proof of concept, POU filter microbiomes were collected from four different locations and analyzed with 16S rRNA gene amplicon sequencing. The analyses revealed distinct microbial communities, with occasional detection of potential pathogens. The findings highlight the importance of local, and if possible, continuous monitoring within and across distribution systems. The continuous operation of POU filters offers an advantage in capturing species that may be missed by instantaneous sampling methods. We suggest that water utilities, public institutions, and regulatory agencies take advantage of end-of-life POU filters for microbial monitoring. This approach can be easily implemented to ensure drinking water safety, especially from microbes of emerging concerns; e.g., pathogenic Legionella and Mycobacterium species.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Evaluating the efficacy of point-of-use water filtration units in Fiji
    Nathan Tintle
    Adam Heynen
    Kristin Van De Griend
    Rachel Ulrich
    Matthew Ojo
    Emma Boven
    Sarah Brokus
    Randall Wade
    Aaron A. Best
    [J]. Tropical Medicine and Health, 47
  • [2] Evaluating the efficacy of point-of-use water filtration units in Fiji
    Tintle, Nathan
    Heynen, Adam
    Van De Griend, Kristin
    Ulrich, Rachel
    Ojo, Matthew
    Boven, Emma
    Brokus, Sarah
    Wade, Randall
    Best, Aaron A.
    [J]. TROPICAL MEDICINE AND HEALTH, 2019, 47 (01)
  • [3] Point-of-use drinking water treatment with membrane filtration and desalination: A tale of two cities
    Walker, W. Shane
    Santiago, Ivonne
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 255
  • [4] Point-of-Use Drinking Water Devices for Assessing Microbial Contamination in Finished Water and Distribution Systems
    Miles, Syreeta L.
    Gerba, Charles P.
    Pepper, Ian I.
    Reynolds, Kelly A.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (05) : 1425 - 1429
  • [5] Performance of microbiological control by a point-of-use filter system for drinking water purification
    SU FengyiLUO MingfangZHANG FeiLI PengLOU KaiXING Xinhui Department of Chemical EngineeringTsinghua UniversityBeijing China College of Chemistry and Chemical EngineeringGraduate University of Chinese Academy of SciencesBeijing China Institute of MicrobiologyXinjiang Academy of Agricultural SciencesUrumqi China
    [J]. Journal of Environmental Sciences, 2009, (09) - 1246
  • [6] The impact of water consumption, point-of-use filtration and exposure categorization on exposure misclassification of ingested drinking water contaminants
    Wright, J. Michael
    Murphy, Patricia A.
    Nieuwenhuijsen, Mark J.
    Savitz, David A.
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2006, 366 (01) : 65 - 73
  • [8] Performance of microbiological control by a point-of-use filter system for drinking water purification
    Su Fengyi
    Luo Mingfang
    Zhang Fei
    Li Peng
    Lou Kai
    Xing Xinhui
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCES, 2009, 21 (09) : 1237 - 1246
  • [9] POINT-OF-USE AND POINT-OF-ENTRY DRINKING-WATER TREATMENT
    ROZELLE, LT
    [J]. JOURNAL AMERICAN WATER WORKS ASSOCIATION, 1987, 79 (10): : 53 - 59
  • [10] GASTROINTESTINAL HEALTH-EFFECTS ASSOCIATED WITH THE CONSUMPTION OF DRINKING-WATER PRODUCED BY POINT-OF-USE DOMESTIC REVERSE-OSMOSIS FILTRATION UNITS
    PAYMENT, P
    FRANCO, E
    RICHARDSON, L
    SIEMIATYCKI, J
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1991, 57 (04) : 945 - 948