Comparative analysis of the clinical techniques used in evaluation of marginal accuracy of cast restoration using stereomicroscopy as gold standard

被引:11
|
作者
Rastogi, Abhishek [1 ]
Kamble, Vikas [1 ]
机构
[1] Saraswati Dent Coll & Hosp, Dept Prosthodont, Lucknow 227105, UP, India
来源
JOURNAL OF ADVANCED PROSTHODONTICS | 2011年 / 3卷 / 02期
关键词
Marginal adaptation; Finish line; Stereomicroscopy; METAL RESTORATIONS; IN-VIVO; CEMENTATION; PLACEMENT; IMPROVE; FIT;
D O I
10.4047/jap.2011.3.2.69
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. This study assessed the effect of preparation design on marginal adaptation and also compared the sensitivity and specificity of clinical evaluation techniques for marginal accuracy of cast restorations to stereomicroscopy. MATERIALS AND METHODS. Three Ivorine molar teeth of different designs were prepared. (A)-A complete crown preparation with buccal shoulder and beveled finish line. (B)-A complete crown preparation with chamfer finish line. (C)-A three-quarter crown preparation with proximal boxes and beveled finish line. Twenty four castings were prepared with eight castings for each design respectively. Each casting underwent examination with an explorer, disclosing media, and a stereomicroscope. Stereomicroscopy at a value less than or equal to 30 microns was used as a gold standard to evaluate the significance of different designs on marginal adaptation. Chi-square tests of independence and Kruskal-Wallis were used to evaluate the effect of preparation design and compare the agreement between examination methods for detection of marginal gap size of greater than or equal to 30 microns (alpha=.05). Sensitivity and specificity for explorer and disclosing media as compared to stereomicroscope was calculated using statistical formula given by Park. RESULTS. The preparation design did not significantly affect overall marginal adaptation. Examination by explorer and disclosing media at 30 mu m revealed 39% and 10.06% sensitivity and 91% and 82% specificity respectively. CONCLUSION. Preparation designs examined in this study did not significantly affect the marginal adaptation of the castings. Commonly used clinical evaluation techniques using explorer and disclosing media appeared to be inadequate for assessment of marginal accuracy. [J Adv Prosthodont 2011;3:69-75]
引用
收藏
页码:69 / 75
页数:7
相关论文
共 50 条
  • [21] Comparative Evaluation of Marginal Accuracy of Metal Copings Fabricated using Direct Metal Laser Sintering, Computer-Aided Milling, Ringless Casting, and Traditional Casting Techniques: An In vitro Study
    James, Annu Eliza
    Umamaheswari, B.
    Lakshmi, C. B. Shanthana
    CONTEMPORARY CLINICAL DENTISTRY, 2018, 9 (03) : 421 - 426
  • [22] Comparative Analysis of Monopolar Electrocautery and Ultrasonic Activated Scalpel in Laparoscopic Cholecystectomy: A Comprehensive Evaluation Using Clinical, Laboratory, and Imaging Techniques
    Jain, Kulbhushan
    Goyal, Divakar
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (06)
  • [23] A comparative evaluation of the diagnostic accuracy of an infrared sensor device with standard mounting procedure in completely edentulous patients: A pilot clinical study
    Kaushik, Aryen
    Kaur, Taranjeet
    Shadaksharappa, Shashidhara Hebbal
    Rani, Pooja
    Sharma, Shikha
    Sinha, Harsh Vardhan
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (05): : 981E1 - 981E8
  • [24] A comparative evaluation of internal and marginal fits of custom post and core fabricated using conventional and two digital techniques: An in vitro study
    Sheth, Vidhi Himanshu
    Gharat, Nikita
    Bhatnagar, Vishrut Mohan
    Gill, Shruti
    Shah, Naisargi P.
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2024, 24 (01): : 95 - 102
  • [25] DIAGNOSTIC-TESTS FOR PNEUMONIA IN VENTILATED PATIENTS - PROSPECTIVE EVALUATION OF DIAGNOSTIC-ACCURACY USING HISTOLOGY AS A DIAGNOSTIC GOLD-STANDARD
    MARQUETTE, CH
    COPIN, MC
    WALLET, F
    NEVIERE, R
    SAULNIER, F
    MATHIEU, D
    DUROCHER, A
    RAMON, P
    TONNEL, AB
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 151 (06) : 1878 - 1888
  • [26] Comparative Evaluation of Denture Retention Using Three Border Moulding Techniques: A Non Randomised Clinical Study
    Mary, Anne
    Nooji, Deviprasad
    Rao, Suhas K.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2024, 18 (11) : ZC40 - ZC45
  • [27] SEM Evaluation of the Marginal Accuracy of Zirconia, Lithium Disilicate, and Composite Single Crowns Created by CAD/CAM Method: Comparative Analysis of Different Materials
    Ferrini, Francesco
    Paolone, Gaetano
    Di Domenico, Giovanna Laura
    Pagani, Nicolo
    Gherlone, Enrico Felice
    MATERIALS, 2023, 16 (06)
  • [28] Evaluation of SARS-CoV-2 Detection Systems Using Clinical Samples and Standard Material: A Comparative Study
    Park, Sunggyun
    Kim, Do-Hoon
    DIAGNOSTICS, 2023, 13 (12)
  • [29] SYSTEMATIC ANALYSIS OF THE DIAGNOSTIC-VALUE OF ECHOCARDIOGRAPHY IN THE EVALUATION OF PERICARDIAL DISEASE USING AUTOPSY FINDINGS AS THE GOLD STANDARD
    LIM, SP
    ELLIS, S
    CHEST, 1986, 89 (06) : S506 - S506
  • [30] Evaluation of precision and accuracy in the trace analysis of heavy metals in biological samples using reference materials and electroanalytical techniques
    Stegen, S
    Queirolo, F
    Marin, C
    Vinagre, F
    Ostapczuk, P
    Valenta, P
    BOLETIN DE LA SOCIEDAD CHILENA DE QUIMICA, 1996, 41 (02): : 137 - 144