A comparative evaluation of internal and marginal fits of custom post and core fabricated using conventional and two digital techniques: An in vitro study

被引:1
|
作者
Sheth, Vidhi Himanshu [1 ,2 ]
Gharat, Nikita [1 ]
Bhatnagar, Vishrut Mohan [1 ]
Gill, Shruti [1 ]
Shah, Naisargi P. [1 ]
机构
[1] TPCTs Terna Dent Coll, Dept Prosthodont Crown & Bridge, Navi Mumbai, Maharashtra, India
[2] TPCTs Terna Dent Coll & Hosp, Dept Prosthodont Crown & Bridge, Plot 12,Sect 22,Opposite Nerul Railway Stn, Navi Mumbai 400706, Maharashtra, India
来源
关键词
Cobalt-chromium post and core; computer-aided designing and computer-aided manufacturing; custom post and core; digital method; FIBER POST; ROOT CANALS; CAD/CAM; TOMOGRAPHY; IMPRESSION;
D O I
10.4103/jips.jips_275_23
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: The purpose of this in vitro study was to comparatively evaluate the marginal and internal fits of cobalt-chromium metal custom post and core fabricated using a conventional technique with two digital techniques. Settings and design: The study was designed in an in-vitro study setting. Materials and methods: Five sets of custom post and core restorations were fabricated using the conventional (Group 1) and two semi digital methods (digital scanning of the resin pattern and computer aided additive manufacturing, and digital scanning of the silicone impression and subsequent computer aided designing [CAD] computer aided manufacturing fabrication) (Group 2 and 3). Marginal and internal fits of the posts were evaluated using a micro computed tomography scan at various points. Statistical analysis used: A one way ANOVA test of the scores was made to evaluate the effect of different methods of custom post and core fabrication on marginal and internal fits. Bonferroni adjusted post hoc tests were conducted for intergroup comparison. Results: Least marginal gap was reported in Group 3 (82.5 +/- 14.36 mu m) followed by Group 1 (110 +/- 25.19 mu m) and Group 2 (112.5 +/- 26.75 mu m). Least internal gap at cervical, middle and apical as well as overall values were observed in Group 3 (78 +/- 9.25 mu m, 72 +/- 7.79 mu m, 160 +/- 15.81 mu m, 103.3 +/- 4.43 mu m) followed by Group 1 (113.5 +/- 25.35 mu m, 132.5 +/- 19.92 mu m, 502 +/- 74.63 mu m, 249.3 +/- 25.44 mu m) and Group 2 (114.5 +/- 21.68 mu m, 133.5 +/- 19.57 mu m, 598 +/- 87.86 mu m, 282 +/- 28.91 mu m) respectively. The results of one-way ANOVA and Bonferroni adjusted post hoc tests for marginal gap did not show any statistically significant difference between the three groups (P > 0.05) but revealed statistically significant difference (P = 0.02) in internal gap values at the cervical, middle, and apical regions as well as overall internal gap region between the three groups. Conclusions: Better marginal and internal fits were observed in custom post and core fabricated by digital scanning of the silicone impression and subsequent CAD as compared to those fabricated by the other two groups.
引用
收藏
页码:95 / 102
页数:8
相关论文
共 50 条
  • [1] Comparative Evaluation of the Marginal Fit of Inlays Fabricated by Conventional and Digital Impression Techniques: A Stereomicroscopic Study
    Sharma, Anamika
    Abraham, Dax
    Gupita, Alpa
    Singh, Arundeep
    Sharma, Naresh
    [J]. CONTEMPORARY CLINICAL DENTISTRY, 2020, 11 (03) : 237 - 244
  • [2] Comparative evaluation of fracture resistance of anterior provisional restorations fabricated using conventional and digital techniques - An in vitro study
    Alam, Maqbul
    Chugh, Anshul
    Kumar, Adarsh
    Rathee, Manu
    Jain, Prachi
    [J]. THE JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2022, 22 (04) : 361 - 367
  • [3] Marginal and internal fit of lithium disilicate endocrowns fabricated using conventional, digital, and combination techniques
    Abduljawad, Danyh Emad
    Rayyan, Mohammad Ramadan
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2022, 34 (04) : 707 - 714
  • [4] Evaluation of custom posts and cores fabricated by two digital technologies in core and post space dimensions
    Wu, Yumin
    Qi, Haowen
    Wang, Danlei
    Liao, Mengyuan
    Zhang, Yuhang
    Zhang, Juan
    Xie, Haifeng
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (06): : 593 - 605
  • [5] Evaluation of the Internal Accuracy of Molar Crowns Fabricated Using Digital and Conventional Impression Techniques
    Tartuk, Bulent Kadir
    Ayna, Emrah
    Basaran, Emine Goncu
    [J]. MEANDROS MEDICAL AND DENTAL JOURNAL, 2018, 19 (03): : 240 - 246
  • [6] Digital evaluation of absolute marginal discrepancy: A comparison of ceramic crowns fabricated with conventional and digital techniques
    Liang, Shanshan
    Yuan, Fusong
    Luo, Xu
    Yu, Zhuoren
    Tang, Zhihui
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (04): : 525 - 529
  • [7] In Vitro Evaluation of the Marginal and Internal Accuracy of Different Types of Dental Ceramic Restorations Fabricated Based on Digital and Conventional Impressions
    Ozsurmeli, Halis
    Turker, Sebnem Begum
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2021, 34 (01) : 61 - 69
  • [8] A COMPARATIVE EVALUATION OF MARGINAL AND INTERNAL ADAPTATION OF COMPLETE CAST COPING FABRICATED USING DIFFERENT PATTERN MATERIALS -AN IN VITRO STUDY
    Shaikh, S. A.
    Chandra, P. K.
    Lekha, K.
    Rao, M.
    Taneja, P.
    [J]. ANNALS OF DENTAL SPECIALTY, 2014, 2 (04): : 118 - 123
  • [9] Marginal and Internal Fit of Ceramic Restorations Fabricated Using Digital Scanning and Conventional Impressions: A Clinical Study
    Lee, Jeong-Hyeon
    Son, Keunbada
    Lee, Kyu-Bok
    [J]. JOURNAL OF CLINICAL MEDICINE, 2020, 9 (12) : 1 - 11
  • [10] In Vitro Study Comparing Retention of Custom Post and Cores Fabricated Using Conventional, CAD/CAM Milling and 3D-Printing Techniques
    Alqarni, Hatem
    AlHelal, Abdulaziz A.
    Jekki, Rami
    Kattadiyil, Mathew T.
    Sayed, Mohammed E.
    Jain, Saurabh
    Vahdati, Seyed Aliakbar
    Dehom, Salem
    [J]. APPLIED SCIENCES-BASEL, 2022, 12 (23):