Comparative analysis of the clinical techniques used in evaluation of marginal accuracy of cast restoration using stereomicroscopy as gold standard

被引:11
|
作者
Rastogi, Abhishek [1 ]
Kamble, Vikas [1 ]
机构
[1] Saraswati Dent Coll & Hosp, Dept Prosthodont, Lucknow 227105, UP, India
来源
JOURNAL OF ADVANCED PROSTHODONTICS | 2011年 / 3卷 / 02期
关键词
Marginal adaptation; Finish line; Stereomicroscopy; METAL RESTORATIONS; IN-VIVO; CEMENTATION; PLACEMENT; IMPROVE; FIT;
D O I
10.4047/jap.2011.3.2.69
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. This study assessed the effect of preparation design on marginal adaptation and also compared the sensitivity and specificity of clinical evaluation techniques for marginal accuracy of cast restorations to stereomicroscopy. MATERIALS AND METHODS. Three Ivorine molar teeth of different designs were prepared. (A)-A complete crown preparation with buccal shoulder and beveled finish line. (B)-A complete crown preparation with chamfer finish line. (C)-A three-quarter crown preparation with proximal boxes and beveled finish line. Twenty four castings were prepared with eight castings for each design respectively. Each casting underwent examination with an explorer, disclosing media, and a stereomicroscope. Stereomicroscopy at a value less than or equal to 30 microns was used as a gold standard to evaluate the significance of different designs on marginal adaptation. Chi-square tests of independence and Kruskal-Wallis were used to evaluate the effect of preparation design and compare the agreement between examination methods for detection of marginal gap size of greater than or equal to 30 microns (alpha=.05). Sensitivity and specificity for explorer and disclosing media as compared to stereomicroscope was calculated using statistical formula given by Park. RESULTS. The preparation design did not significantly affect overall marginal adaptation. Examination by explorer and disclosing media at 30 mu m revealed 39% and 10.06% sensitivity and 91% and 82% specificity respectively. CONCLUSION. Preparation designs examined in this study did not significantly affect the marginal adaptation of the castings. Commonly used clinical evaluation techniques using explorer and disclosing media appeared to be inadequate for assessment of marginal accuracy. [J Adv Prosthodont 2011;3:69-75]
引用
收藏
页码:69 / 75
页数:7
相关论文
共 50 条
  • [41] A statistical method was used for the meta-analysis of tests for latent TB in the absence of a gold standard, combining random-effect and latent-class methods to estimate test accuracy
    Sadatsafavi, Mohsen
    Shahidi, Neal
    Marra, Fawziah
    FitzGerald, Mark J.
    Elwood, Kevin R.
    Guo, Na
    Marra, Carlo A.
    JOURNAL OF CLINICAL EPIDEMIOLOGY, 2010, 63 (03) : 257 - 269
  • [42] Comparative evaluation of standard dilution method and commercial kit for frozen plate antifungal susceptibility testing of yeasts using 200 clinical isolates
    Makimura, K
    Suzuki, T
    Tamura, T
    Ikedo, M
    Hanazawa, R
    Takahashi, Y
    Yamada, Y
    Uchida, K
    Yamaguchi, H
    MICROBIOLOGY AND IMMUNOLOGY, 2004, 48 (10) : 747 - 753
  • [43] Evaluation of the Diagnostic Accuracy of a Typhoid IgM Flow Assay for the Diagnosis of Typhoid Fever in Cambodian Children Using a Bayesian Latent Class Model Assuming an Imperfect Gold Standard
    Moore, Catrin E.
    Pan-Ngum, Wirichada
    Wijedoru, Lalith P. M.
    Sona, Soeng
    Tran Vu Thieu Nga
    Pham Thanh Duy
    Phat Voong Vinh
    Chheng, Kheng
    Kumar, Varun
    Emary, Kate
    Carter, Michael
    White, Lisa
    Baker, Stephen
    Day, Nicholas P. J.
    Parry, Christopher M.
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2014, 90 (01): : 114 - 120
  • [44] Most nosocomial pneumonias are not due to nosocomial bacteria in ventilated patients. Evaluation of the accuracy of the 48 h time cut-off using carriage as the gold standard
    Silvestri, L
    Sarginson, RE
    Hughes, J
    Milanese, M
    Gregori, D
    Van Saene, HKF
    ANAESTHESIA AND INTENSIVE CARE, 2002, 30 (03) : 275 - 282
  • [45] Comparative analysis of dental implant placement accuracy: Semi-active robotic versus free-hand techniques: A randomized controlled clinical trial
    Yang, Fan
    Chen, Jianping
    Cao, Ruijue
    Tang, Qingwei
    Liu, Haiyan
    Zheng, Yuchen
    Liu, BeiLei
    Huang, Min
    Wang, Zhenshi
    Ding, Yude
    Wang, Linhong
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (06) : 1149 - 1161
  • [46] Comparative Analysis of DC-DC Converter Topologies and MPPT Techniques used in SPV Based Water Pumping System Using BLDC motor
    Kumar, Manish
    Anwar, Md Nishat
    Kumar, Anand
    2018 2ND INTERNATIONAL CONFERENCE ON POWER, ENERGY AND ENVIRONMENT: TOWARDS SMART TECHNOLOGY (ICEPE), 2018,
  • [47] Comparative analysis of a monoclonal antibody-based Streptococcus mutans detection method with selective culture assays using polymerase chain reaction as a gold standard
    Gu, Fang
    Qi, Fengxia
    Anderson, Maxwell H.
    Shi, Wenyuan
    HYBRIDOMA, 2006, 25 (06): : 372 - 377
  • [48] Comparative Analysis of Three Different Impression Techniques for Impression Defects and Dimensional Accuracy Using a Digital Intraoral Scanner for Fixed Partial Dentures: An In Vivo Study
    Khatuja, Neha G.
    Katiyar, Pratibha
    Tarannum, Fauzia
    Pandey, Kaushik Kumar
    Katiyar, Abhishek Kumar
    Afzal, Zoya
    Ali, Aman
    Roy, Ispita
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (05)
  • [49] Accuracy of PCR targeting different markers for Staphylococcus aureus identification: a comparative study using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry as the gold standard
    Saraiva, Mauro M.
    De Leon, Candice M.
    Santos, Silvana C.
    Stipp, Danilo T.
    Souza, Miliane M.
    Santos Filho, Lauro
    Gebreyes, Wondwossen A.
    Oliveira, Celso J.
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2018, 30 (02) : 252 - 255
  • [50] Comparative clinical evaluation of two different techniques of local anaesthesia in the posterior mandible using 4% articaine with 1: 100,000 adrenaline
    Marjanovic, Uros
    Jurisic, Milan
    Brkovic, Bozidar
    Jakovljevic, Aleksandar
    Milicic, Biljana
    Marjanovic, Marjan
    Ivanovic, Julija
    VOJNOSANITETSKI PREGLED, 2017, 74 (11) : 1030 - 1035