Bolus Calculator: A Review of Four "Smart" Insulin Pumps

被引:98
|
作者
Zisser, Howard [1 ,2 ]
Robinson, Lauren [1 ]
Bevier, Wendy [1 ]
Dassau, Eyal [1 ,2 ,3 ]
Ellingsen, Christian [1 ,2 ]
Doyle, Francis J., III [1 ,2 ,3 ]
Jovanovic, Lois [1 ,2 ,3 ]
机构
[1] Sansum Diabet Res Inst, Santa Barbara, CA 93105 USA
[2] Univ Calif Santa Barbara, Dept Chem Engn, Santa Barbara, CA 93106 USA
[3] Univ Calif Santa Barbara, Biomol Sci & Engn Program, Santa Barbara, CA 93106 USA
关键词
D O I
10.1089/dia.2007.0284
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The use of continuous subcutaneous insulin infusion (CSII) pumps has been gaining popularity since 1979, when the first research report on insulin pumps was published. Insulin pumps-small medical devices that are programmed to infuse insulin through a catheter placed under the skin-are a replacement for multiple daily injections of insulin. They are currently being used by 375,000 people with type 1 diabetes, many of whom prefer CSII to multiple daily injections because of the increased flexibility of diet and exercise, increased convenience and precision when dosing, and better predictability of blood glucose levels that insulin pumps can provide when used correctly. Recent pump manufacturers have engineered a new feature called a bolus calculator, which calculates bolus insulin doses based on input from the pump wearer, which functions to help patients obtain optimum control over blood glucose levels. The bolus calculator takes into account the patient's current blood glucose, target blood glucose, amount of carbohydrate consumed, and other factors such as insulin sensitivity and insulin-to-carbohydrate ratio as well as duration of insulin action ("insulin on board"). Each pump company calculates insulin doses in a slightly different way. This article will review differences in bolus calculator recommendations between four insulin pumps, as well as errors that may occur when using bolus calculators. It will also include an in silico simulation of a meal followed by a snack using multiple insulin decay curves.
引用
收藏
页码:441 / 444
页数:4
相关论文
共 50 条
  • [41] Automated Bolus Calculators and Connected Insulin Pens: A Smart Combination for Multiple Daily Injection Insulin Therapy
    Ahn, David T.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (03): : 605 - 609
  • [42] Comparison of treatment with continuous subcutaneous insulin infusion versus multiple daily insulin injections with bolus calculator in patients with type 1 diabetes
    Perez-Garcia, L.
    Goni-Iriarte, M. J.
    Garcia-Mouriz, M.
    ENDOCRINOLOGIA Y NUTRICION, 2015, 62 (07): : 331 - 337
  • [43] Insulin Pumps: Review of Technological Advancement in Diabetes Management
    Sora, Nicoleta D.
    Shashpal, Fnu
    Bond, Elizabeth A.
    Jenkins, Alicia J.
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2019, 358 (05): : 326 - 331
  • [44] Intelligent Dual Basal-Bolus Calculator for Multiple Daily Insulin Injections via Offline Reinforcement Learning
    Yoo, Junyoung
    Rachim, Vega Pradana
    Jung, Suyeon
    Park, Sung-Min
    IEEE ACCESS, 2024, 12 : 192572 - 192585
  • [45] The Use of a Smart Bolus Calculator Informed by Real-time Insulin Sensitivity Assessments Reduces Postprandial Hypoglycemia Following an Aerobic Exercise Session in Individuals With Type 1 Diabetes
    Fabris, Chiara
    Nass, Ralf M.
    Pinnata, Jennifer
    Carr, Kelly A.
    Koravi, Chaitanya L. K.
    Barnett, Charlotte L.
    Oliveri, Mary C.
    Anderson, Stacey M.
    Chernavvsky, Daniel R.
    Breton, Marc D.
    DIABETES CARE, 2020, 43 (04) : 799 - 805
  • [46] Method for automatic adjustment of an insulin bolus calculator: In silico robustness evaluation under intra-day variability
    Herrero, Pau
    Pesl, Peter
    Bondia, Jorge
    Reddy, Monika
    Oliver, Nick
    Georgiou, Pantelis
    Toumazou, Christofer
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2015, 119 (01) : 1 - 8
  • [47] Comparison of insulin infusion pumps versus basal/bolus insulin injections for treatment of type 1 diabetes mellitus in clinical practice
    Myneni, Anjana
    Aldasouqi, Saleh
    Page, Connie
    Weller, Leslie
    Carella, Michael
    Gossain, Ved
    DIABETES, 2008, 57 : A556 - A556
  • [48] Optimal prandial timing of bolus insulin in diabetes management: a review
    Slattery, D.
    Amiel, S. A.
    Choudhary, P.
    DIABETIC MEDICINE, 2018, 35 (03) : 306 - 316
  • [49] Insulin Pumps
    Pickup, John C.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 : S32 - S41
  • [50] The use of insulin pumps with meal bolus alarms in children with type 1 diabetes to improve glycemic control
    Chase, HP
    Horner, B
    McFann, K
    Yetzer, H
    Gaston, J
    Banion, C
    Fiallo-Scharer, R
    Slover, R
    Klingensmith, G
    DIABETES CARE, 2006, 29 (05) : 1012 - 1015