Bolus Calculator: A Review of Four "Smart" Insulin Pumps

被引:98
|
作者
Zisser, Howard [1 ,2 ]
Robinson, Lauren [1 ]
Bevier, Wendy [1 ]
Dassau, Eyal [1 ,2 ,3 ]
Ellingsen, Christian [1 ,2 ]
Doyle, Francis J., III [1 ,2 ,3 ]
Jovanovic, Lois [1 ,2 ,3 ]
机构
[1] Sansum Diabet Res Inst, Santa Barbara, CA 93105 USA
[2] Univ Calif Santa Barbara, Dept Chem Engn, Santa Barbara, CA 93106 USA
[3] Univ Calif Santa Barbara, Biomol Sci & Engn Program, Santa Barbara, CA 93106 USA
关键词
D O I
10.1089/dia.2007.0284
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The use of continuous subcutaneous insulin infusion (CSII) pumps has been gaining popularity since 1979, when the first research report on insulin pumps was published. Insulin pumps-small medical devices that are programmed to infuse insulin through a catheter placed under the skin-are a replacement for multiple daily injections of insulin. They are currently being used by 375,000 people with type 1 diabetes, many of whom prefer CSII to multiple daily injections because of the increased flexibility of diet and exercise, increased convenience and precision when dosing, and better predictability of blood glucose levels that insulin pumps can provide when used correctly. Recent pump manufacturers have engineered a new feature called a bolus calculator, which calculates bolus insulin doses based on input from the pump wearer, which functions to help patients obtain optimum control over blood glucose levels. The bolus calculator takes into account the patient's current blood glucose, target blood glucose, amount of carbohydrate consumed, and other factors such as insulin sensitivity and insulin-to-carbohydrate ratio as well as duration of insulin action ("insulin on board"). Each pump company calculates insulin doses in a slightly different way. This article will review differences in bolus calculator recommendations between four insulin pumps, as well as errors that may occur when using bolus calculators. It will also include an in silico simulation of a meal followed by a snack using multiple insulin decay curves.
引用
收藏
页码:441 / 444
页数:4
相关论文
共 50 条
  • [31] THE INFLUENCE OF BOLUS TYPE IN GLYCAEMIC CONTROL OF TYPE 1 DIABETIC CHILDREN ON INSULIN PUMPS
    Silva, L.
    Belinha, F.
    Serra Caetano, J.
    Cardoso, R.
    Dinis, I.
    Mirante, A.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 : A170 - A170
  • [32] EFFECTS OF INSULIN PUMPS ON DIABETIC RETINOPATHY: A REVIEW
    Totolici, Geanina
    Cristina, Serban
    Tiutiuca, Carmen
    Tutunaru, Dana
    ROMANIAN JOURNAL OF ORAL REHABILITATION, 2023, 15 (02): : 148 - 160
  • [33] Insulin pumps in children-a systematic review
    Mohammed Al-Beltagi
    Nermin Kamal Saeed
    Adel Salah Bediwy
    Reem Elbeltagi
    World Journal of Clinical Pediatrics, 2022, 11 (06) : 463 - 484
  • [34] CALCULATOR - SMART LIGHTER
    不详
    DESIGN NEWS, 1979, 35 (03) : 16 - 16
  • [35] USE OF BOLUS CALCULATOR AND CARBOHYDRATE COUNTING IN 146 SINGLE-CENTER PATIENTS ON INSULIN PUMP THERAPY
    Rapisarda, V.
    Tumminia, A.
    Egiziano, C.
    Tomaselli, L.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2016, 18 : A111 - A111
  • [36] USING BOLUS CALCULATOR IMPROVES METABOLIC CONTROL OF PATIENTS WITH DIABETES IN TREATMENT WITH MULTIPLE DAILY INSULIN INJECTIONS
    Lainez Lopez, M.
    Gonzalez Navarro, I.
    J. Hidalgo-Castellon, A.
    Rodriguez Ortega, P.
    Lopez Perez, M. J.
    Roldan Mayorga, E.
    Garcia Diez, C.
    Rebollo Perez, M. I.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 : A121 - A121
  • [37] Postprandial glucose excursions following four methods of bolus insulin administration using an insulin pump
    Chase, HP
    Saib, SZ
    MacKenzie, T
    Hansen, M
    Garg, SK
    DIABETES, 2001, 50 : A92 - A92
  • [38] The dual-wave bolus feature in type 1 diabetes adult users of insulin pumps
    Klupa, Tomasz
    Skupien, Jan
    Cyganek, Katarzyna
    Katra, Barbara
    Sieradzki, Jacek
    Malecki, Maciej T.
    ACTA DIABETOLOGICA, 2011, 48 (01) : 11 - 14
  • [39] The dual-wave bolus feature in type 1 diabetes adult users of insulin pumps
    Klupa, T.
    Skupien, J.
    Cyganek, K.
    Katra, B.
    Sieradzki, J.
    Malecki, M. T.
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2010, 40 : 81 - 81
  • [40] The dual-wave bolus feature in type 1 diabetes adult users of insulin pumps
    Tomasz Klupa
    Jan Skupien
    Katarzyna Cyganek
    Barbara Katra
    Jacek Sieradzki
    Maciej T. Malecki
    Acta Diabetologica, 2011, 48 : 11 - 14