Bolus Calculator: A Review of Four "Smart" Insulin Pumps

被引:98
|
作者
Zisser, Howard [1 ,2 ]
Robinson, Lauren [1 ]
Bevier, Wendy [1 ]
Dassau, Eyal [1 ,2 ,3 ]
Ellingsen, Christian [1 ,2 ]
Doyle, Francis J., III [1 ,2 ,3 ]
Jovanovic, Lois [1 ,2 ,3 ]
机构
[1] Sansum Diabet Res Inst, Santa Barbara, CA 93105 USA
[2] Univ Calif Santa Barbara, Dept Chem Engn, Santa Barbara, CA 93106 USA
[3] Univ Calif Santa Barbara, Biomol Sci & Engn Program, Santa Barbara, CA 93106 USA
关键词
D O I
10.1089/dia.2007.0284
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The use of continuous subcutaneous insulin infusion (CSII) pumps has been gaining popularity since 1979, when the first research report on insulin pumps was published. Insulin pumps-small medical devices that are programmed to infuse insulin through a catheter placed under the skin-are a replacement for multiple daily injections of insulin. They are currently being used by 375,000 people with type 1 diabetes, many of whom prefer CSII to multiple daily injections because of the increased flexibility of diet and exercise, increased convenience and precision when dosing, and better predictability of blood glucose levels that insulin pumps can provide when used correctly. Recent pump manufacturers have engineered a new feature called a bolus calculator, which calculates bolus insulin doses based on input from the pump wearer, which functions to help patients obtain optimum control over blood glucose levels. The bolus calculator takes into account the patient's current blood glucose, target blood glucose, amount of carbohydrate consumed, and other factors such as insulin sensitivity and insulin-to-carbohydrate ratio as well as duration of insulin action ("insulin on board"). Each pump company calculates insulin doses in a slightly different way. This article will review differences in bolus calculator recommendations between four insulin pumps, as well as errors that may occur when using bolus calculators. It will also include an in silico simulation of a meal followed by a snack using multiple insulin decay curves.
引用
收藏
页码:441 / 444
页数:4
相关论文
共 50 条
  • [21] Satisfaction of Healthcare Professionals and People With Diabetes With an Insulin Bolus Calculator Mobile Application
    Katz, Laurence B.
    Hurrell, Graham
    Venugopal, Usha
    Cameron, Hilary
    Shearer, David M.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2021, 15 (04): : 885 - 890
  • [22] Carbohydrate counting with a bolus calculator improves post-prandial blood glucose levels in children and adolescents with type 1 diabetes using insulin pumps
    Enander, Rebecka
    Gundevall, Christer
    Stroemgren, Agneta
    Chaplin, John
    Hanas, Ragnar
    PEDIATRIC DIABETES, 2012, 13 (07) : 545 - 551
  • [23] The Effect of Using the Insulin Pump Bolus Calculator Compared to Standard Insulin Dosage Calculations in Patients with Type 1 Diabetes Mellitus - Systematic Review
    Ramotowska, A.
    Golicki, D.
    Dzygalo, K.
    Szypowska, A.
    EXPERIMENTAL AND CLINICAL ENDOCRINOLOGY & DIABETES, 2013, 121 (05) : 248 - 254
  • [24] On heat pumps in smart grids: A review
    Fischer, David
    Madani, Hatef
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 70 : 342 - 357
  • [25] USE OF INSULIN-BOLUS CALCULATOR FREE STYLE INSULINX® IN DIABETES TYPE-1 PATIENTS TREATED WITH BASAL-BOLUS INSULIN REGIMEN
    Delgado, E.
    Tejera, C.
    Bellido, D.
    Morales, F.
    Porca, C.
    Diaz Perez De Madrid, Jose
    DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 : A74 - A74
  • [26] Optimum bolus wizard settings in insulin pumps in children with Type 1 diabetes
    Andersen, A. J. B.
    Ostenfeld, A.
    Pipper, C. B.
    Olsen, B. S.
    Hertz, A. M.
    Jorgensen, L. K.
    Hogsmose, J.
    Svensson, J.
    DIABETIC MEDICINE, 2016, 33 (10) : 1360 - 1365
  • [27] Impact of the kinetics administration of bolus materials by insulin pumps implanted on the glycemic profils
    Djakouré, C
    Breilh, D
    Roger, P
    Catargi, B
    DIABETES & METABOLISM, 2006, 32 : S72 - S72
  • [28] Smart Bolus Estimation Taking into Account the Amount of Insulin on Board
    Al-Taee, Ahmad M.
    Al-Taee, Majid A.
    Al-Nuaimy, Waleed
    Muhsin, Zahra J.
    AlZu'bi, Hamzah
    CIT/IUCC/DASC/PICOM 2015 IEEE INTERNATIONAL CONFERENCE ON COMPUTER AND INFORMATION TECHNOLOGY - UBIQUITOUS COMPUTING AND COMMUNICATIONS - DEPENDABLE, AUTONOMIC AND SECURE COMPUTING - PERVASIVE INTELLIGENCE AND COMPUTING, 2015, : 1052 - 1057
  • [29] Subcutaneous Bolus Output by Insulin Pumps in Patients with Type-1-Diabetes - Effect of a Bolus Length on the Absorption Kinetics by rapid acting Insulin
    Kojzar, Harald
    Urschitz, Martina
    Lehki, Barbara
    Mader, Julia
    Ehrmann, Markus
    Ellmerer, Martin
    Pieber, Thomas R.
    Regittnig, Werner
    WIENER KLINISCHE WOCHENSCHRIFT, 2013, 125 : S14 - S15
  • [30] EVERYDAY USE OF AN AUTOMATED BOLUS CALCULATOR
    Schmidt, S.
    Norgaard, K.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 : A98 - A98