The aim of this study was to quantify the levels of transmitted radiation arising from the use of intra-oral dental x-ray equipment and scattered radiation arising from the use of both intra-oral and panoramic x-ray equipment. Levels of scattered radiation were measured at 1 m from a phantom, using an ion chamber with a volume of 1800 cm(3). Transmitted radiation was measured using both (i) a phantom and dose-area product (DAP) meter and (ii) a patient and a 1800 cm(3) ion chamber. For intra-oral radiography the patient study gave a maximum transmission of 1.80% (range 0.04-1.80%, mean 0.26%) and the phantom study gave a maximum transmission of 6% (range 2-6%, mean 5%). The maximum scattered radiation, per unit DAP, was 5.5 nGy (mGy cm(2))(-1) at 70 kVp and a distance of 1 m. For panoramic radiography the maximum scattered radiation was 9.3 nGy (mGy cm(2))(-1) at 80 kVp and a distance of 1 m. Dose values are presented to enable the calculation of adequate protective measures for dental radiography rooms. Previous studies have used a phantom and measured radiation doses at 1 m from the phantom to determine the radiation dose transmitted through a patient, whereas this study uses both patient and phantom measurements together with a large-area dosemeter, positioned to capture the entire x-ray beam, to ensure that more realistic dose measurements can be made.
引用
收藏
页码:793 / 806
页数:14
相关论文
共 50 条
  • [11] Comparative analysis of tomography based on transmitted and scattered X-rays
    Gorshkov, V. A.
    Kroening, M.
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2006, 42 (04) : 278 - 286
  • [12] THE REFLECTION OF X-RAYS AND THE X-RAY MICROSCOPE
    RIESER, LM
    PHYSICAL REVIEW, 1952, 85 (04): : 764 - 764
  • [13] Control of the Low-energy X-rays by Using MCNP5 and Numerical Analysis for a New Concept Intra-oral X-ray Imaging System
    Jangyong Huh
    Yunseo Ji
    Rena Lee
    Journal of the Korean Physical Society, 2018, 72 : 1078 - 1085
  • [14] X-RAY MICRODENSITOMETRY BY MEANS OF X-RAYS
    CARDOSO, LP
    ELLIS, SC
    ACTA CRYSTALLOGRAPHICA SECTION A, 1978, 34 : S339 - S340
  • [15] X-ray skin without x-rays
    Schufrmann, H
    DERMATOLOGISCHE WOCHENSCHRIFT, 1937, 105 (27/52): : 945 - 948
  • [16] Control of the Low-energy X-rays by Using MCNP5 and Numerical Analysis for a New Concept Intra-oral X-ray Imaging System
    Huh, Jangyong
    Ji, Yunseo
    Lee, Rena
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2018, 72 (09) : 1078 - 1085
  • [17] X-ray Fluorescence (XRF) Assay Using Laser Compton Scattered (LCS) X-rays
    Naeem, Syed F.
    Chouffani, Khalid
    Wells, Douglas P.
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2009, 1099 : 843 - 846
  • [18] Geometrical Calibration Method For X-ray Intra-oral Digital Tomosynthesis
    Yang, Yao
    Li, Liang
    Chen, Zhiqiang
    Chang, Ming
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [19] CLINICAL EVALUATION OF A PROTOTYPE INTRA-ORAL SOURCE X-RAY SYSTEM
    LIEBERMAN, JE
    WEBBER, RL
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1978, 46 (02): : 318 - 327
  • [20] An electronic survey of opinions on the compatibility of current X-ray generators with intra-oral digital X-ray systems
    Hayakawa, Y
    Kuroyanagi, K
    Chen, SK
    Farman, AG
    Welander, U
    DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (06) : 344 - 347