The aim of this study was to quantify the levels of transmitted radiation arising from the use of intra-oral dental x-ray equipment and scattered radiation arising from the use of both intra-oral and panoramic x-ray equipment. Levels of scattered radiation were measured at 1 m from a phantom, using an ion chamber with a volume of 1800 cm(3). Transmitted radiation was measured using both (i) a phantom and dose-area product (DAP) meter and (ii) a patient and a 1800 cm(3) ion chamber. For intra-oral radiography the patient study gave a maximum transmission of 1.80% (range 0.04-1.80%, mean 0.26%) and the phantom study gave a maximum transmission of 6% (range 2-6%, mean 5%). The maximum scattered radiation, per unit DAP, was 5.5 nGy (mGy cm(2))(-1) at 70 kVp and a distance of 1 m. For panoramic radiography the maximum scattered radiation was 9.3 nGy (mGy cm(2))(-1) at 80 kVp and a distance of 1 m. Dose values are presented to enable the calculation of adequate protective measures for dental radiography rooms. Previous studies have used a phantom and measured radiation doses at 1 m from the phantom to determine the radiation dose transmitted through a patient, whereas this study uses both patient and phantom measurements together with a large-area dosemeter, positioned to capture the entire x-ray beam, to ensure that more realistic dose measurements can be made.
引用
收藏
页码:793 / 806
页数:14
相关论文
共 50 条
  • [31] Reflection of X-rays and X-ray fringes.
    de Broglie, M
    NATURE, 1913, 91 : 161 - 162
  • [32] X-RAY PHOTONICS Bending X-rays with nanochannels
    Pelliccia, Daniele
    NATURE PHOTONICS, 2016, 10 (02) : 75 - 77
  • [33] Digital X-ray radiogrammetry on hand X-rays
    Baadegaard, N
    Linde, R
    Wendt, O
    Rosholm, A
    BONE, 2001, 28 (05) : S176 - S176
  • [34] X-RAY PHOTONICS Transient gratings with X-rays
    Beye, Martin
    NATURE PHOTONICS, 2021, 15 (07) : 490 - 492
  • [35] The Photographic Effect of X-rays and X-ray Spectra
    Barkla, C. G.
    Martyn, G. H.
    PHILOSOPHICAL MAGAZINE, 1913, 25 (146) : 296 - 300
  • [36] Interference of nuclear Bragg scattered x-rays in x-ray interferometer with large optical path difference
    Univ of Tokyo, Tokyo, Japan
    Jpn J Appl Phys Part 1 Regul Pap Short Note Rev Pap, 10 (5862-5868):
  • [37] X-ray fluorescence analysis of lead in tin coating using the theoretical intensity of scattered x-rays
    Ochi, H.
    Watanabe, S.
    Nakamura, H.
    X-RAY SPECTROMETRY, 2008, 37 (03) : 245 - 248
  • [38] Authentication of vegetable oils by confocal X-ray scattering analysis with coherent/incoherent scattered X-rays
    Li, Fangzuo
    Liu, Zhiguo
    Sun, Tianxi
    FOOD CHEMISTRY, 2016, 210 : 435 - 441
  • [39] Measurement of Compton scattered electrons using monochromatic x-rays
    Hollerman, WA
    Guardala, NA
    Land, DJ
    Glass, GA
    Price, JL
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2001, 576 : 193 - 196
  • [40] Combined measurement of X-ray photon correlation spectroscopy and diffracted X-ray tracking using pink beam X-rays
    Shinohara, Yuya
    Watanabe, Akira
    Kishimoto, Hiroyuki
    Amemiya, Yoshiyuki
    JOURNAL OF SYNCHROTRON RADIATION, 2013, 20 : 801 - 804