A robust and accurate surrogate method for monitoring the frequency and duration of combined sewer overflows

被引:13
|
作者
Hofer, Thomas [1 ]
Montserrat, Albert [2 ]
Gruber, Guenter [1 ]
Gamerith, Valentin [1 ,3 ]
Corominas, Lluis [2 ]
Muschalla, Dirk [1 ]
机构
[1] Graz Univ Technol, Inst Urban Water Management & Landscape Water Eng, Stremayrgasse 10-I, A-8010 Graz, Austria
[2] Univ Girona, Catalan Inst Water Res Sci & Technol Pk, H2O Bldg,Emili Grahit 101, Girona 17003, Spain
[3] Hydroconsult GmbH, Engn Co Environm Engn & Water Management, St Veiter Str 11a, A-8045 Graz, Austria
关键词
Combined sewer overflow; Event detection; Low-cost; Monitoring; Temperature; Surrogate measurement; VALIDATION; LOADS;
D O I
10.1007/s10661-018-6589-3
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Discharges of untreated wastewater from combined sewer overflows (CSOs) can affect hydraulic stress and have significant environmental impacts on receiving water bodies. Common flow rate and water level sensors for monitoring of CSO events are expensive in terms of investment costs, installation, operation and maintenance. This paper presents a novel surrogate method to detect CSO events by using two low-cost temperature sensors. The novelty is the experimental setup for installation of temperature sensors in CSO structures and an algorithm developed to automatically calculate the duration of CSO events considering the response time of the system. The occurrence and duration of CSO events is computed based on the convergence of the two temperature signals. The method was tested under field conditions in a CSO structure, and the results were compared to the information gathered from a parallel installed flow sensor. The application of two temperature sensors installed inside a CSO structure was proven to be robust and accurate for the automatic detection of the occurrence and duration of CSO events. Within the 7-month test phase, 100% of the 20 CSO events could be detected without false detections. The accuracy of detecting the start and end of the CSO events was 2 min in comparison to the flow sensor.
引用
收藏
页数:18
相关论文
共 25 条
  • [1] A robust and accurate surrogate method for monitoring the frequency and duration of combined sewer overflows
    Thomas Hofer
    Albert Montserrat
    Guenter Gruber
    Valentin Gamerith
    Lluis Corominas
    Dirk Muschalla
    Environmental Monitoring and Assessment, 2018, 190
  • [2] A METHODOLOGY FOR MONITORING THE PERFORMANCE OF COMBINED SEWER OVERFLOWS
    BALMFORTH, DJ
    LONSDALE, K
    NUSSEY, BB
    WALSH, M
    JOURNAL OF THE CHARTERED INSTITUTION OF WATER AND ENVIRONMENTAL MANAGEMENT, 1995, 9 (05): : 510 - 518
  • [3] Combined sewer overflows: relating event duration monitoring data to wastewater systems' capacity in England
    Giakoumis, T.
    Voulvoulis, N.
    ENVIRONMENTAL SCIENCE-WATER RESEARCH & TECHNOLOGY, 2023, 9 (03) : 707 - 722
  • [4] Intensive monitoring of conventional and surrogate quality parameters in a highly urbanized river affected by multiple combined sewer overflows
    Copetti, D.
    Marziali, L.
    Viviano, G.
    Valsecchi, L.
    Guzzella, L.
    Capodaglio, A. G.
    Tartari, G.
    Polesello, S.
    Valsecchi, S.
    Mezzanotte, V
    Salerno, F.
    WATER SUPPLY, 2019, 19 (03) : 953 - 966
  • [5] Use of weather radar for combined sewer overflows monitoring and control
    Sempere-Torres, D
    Corral, C
    Raso, J
    Malgrat, P
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1999, 125 (04): : 372 - 380
  • [6] A STRATEGY FOR MONITORING THE IMPACTS OF COMBINED SEWER OVERFLOWS ON THE OHIO RIVER
    VICORY, AH
    TENNANT, PA
    WATER SCIENCE AND TECHNOLOGY, 1994, 30 (01) : 167 - 175
  • [7] Use of weather radar for combined sewer overflows monitoring and control
    Sempere-Torres, Daniel
    Corral, Carles
    Raso, Jordi
    Malgrat, Pere
    Journal of Environmental Engineering, 1999, 125 (04): : 372 - 380
  • [8] Using data from monitoring combined sewer overflows to assess, improve, and maintain combined sewer systems
    Montserrat, A.
    Bosch, Ll
    Kiser, M. A.
    Poch, M.
    Corominas, Ll
    SCIENCE OF THE TOTAL ENVIRONMENT, 2015, 505 : 1053 - 1061
  • [9] Field validation of a new low-cost method for determining occurrence and duration of combined sewer overflows
    Montserrat, A.
    Gutierrez, O.
    Poch, M.
    Corominas, Ll
    SCIENCE OF THE TOTAL ENVIRONMENT, 2013, 463 : 904 - 912
  • [10] The frequency of combined sewer overflows during flood events in the receiving water
    Sartor, J
    WATER RESOURCES ENGINEERING 98, VOLS 1 AND 2, 1998, : 1589 - 1594