Use of weather radar for combined sewer overflows monitoring and control

被引:0
|
作者
Sempere-Torres, Daniel [1 ]
Corral, Carles [1 ]
Raso, Jordi [2 ]
Malgrat, Pere [3 ]
机构
[1] Dept. d'Enginyeria Hidr., M., XAHIME, Univ. Politecnica de Catalunya, Jordi Girona, 1-3, D1, 08034 Barcelona, Spain
[2] Clavegueram Barcelona S. A. Acer, 16, 08038 Barcelona, Spain
[3] Projects and Works Dept., Clavegueram Barcelona S. A. Acer. 16, 08038 Barcelona, Spain
来源
Journal of Environmental Engineering | 1999年 / 125卷 / 04期
关键词
Climate change - Computer simulation - Discharge (fluid mechanics) - Doppler radar - Flow of fluids - Meteorological radar - Monitoring - Rain - Rain gages - Real time systems - Water pollution;
D O I
暂无
中图分类号
学科分类号
摘要
In the Mediterranean region, climatological factors make combined sewer overflows a major urban pollution problem that should be monitored and controlled. Some online management solutions require the use of real-time models to forecast flows at the most sensitive points of the combined sewer systems. These models need a very good time and spatial resolution of the rainfall field, which is not sufficiently reproduced by a conventional rain-gauge network. This paper presents a case study where the use of rainfall estimates from weather radar pictures is compared with the use of a rain-gauge network in terms of the ability to predict sewer flows in an urban basin in Barcelona, Spain. The results show that the use of radar data enables the combined sewer systems model to improve the reproduction of observed flows, and they provide support for the idea that the spatial description of rainfall is a key problem in modeling the events giving rise to combined sewer overflows.
引用
收藏
页码:372 / 380
相关论文
共 50 条
  • [1] Use of weather radar for combined sewer overflows monitoring and control
    Sempere-Torres, D
    Corral, C
    Raso, J
    Malgrat, P
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1999, 125 (04): : 372 - 380
  • [2] STRATEGIES TO CONTROL COMBINED SEWER OVERFLOWS
    BERON, P
    BRIERE, F
    ROUSSELLE, J
    RILEY, JP
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1988, 114 (02): : 454 - 459
  • [3] MANAGEMENT AND CONTROL OF COMBINED SEWER OVERFLOWS
    FIELD, R
    STRUZESKI, EJ
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1972, 44 (07): : 1393 - +
  • [4] Remote control of combined sewer overflows
    Anderson, J.J.
    Callery, R.L.
    Journal of the Water Pollution Control Federation, 1974, 46 (11): : 2555 - 2564
  • [5] A METHODOLOGY FOR MONITORING THE PERFORMANCE OF COMBINED SEWER OVERFLOWS
    BALMFORTH, DJ
    LONSDALE, K
    NUSSEY, BB
    WALSH, M
    JOURNAL OF THE CHARTERED INSTITUTION OF WATER AND ENVIRONMENTAL MANAGEMENT, 1995, 9 (05): : 510 - 518
  • [6] REMOTE-CONTROL OF COMBINED SEWER OVERFLOWS
    ANDERSON, JJ
    CALLERY, RL
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1974, 46 (11): : 2555 - 2564
  • [7] Discussion on control measures of combined sewer overflows
    Ou, Yanglin
    Chen, Zhili
    RENEWABLE AND SUSTAINABLE ENERGY, PTS 1-7, 2012, 347-353 : 1856 - 1859
  • [8] COMBINED SEWER OVERFLOWS
    FIELD, R
    CIVIL ENGINEERING, 1973, 43 (02): : 57 - 60
  • [9] New tunnel system to eliminate sanitary sewer overflows and control combined sewer overflows in Hartford, Connecticut
    Nasri, V.
    Haynes, C. E.
    WATER PRACTICE AND TECHNOLOGY, 2015, 10 (02): : 282 - 290
  • [10] Feasibility of real time control of combined sewer overflows
    Schilling, Wolfgang
    Civil Engineering Practice, 1992, 7 (02):