Field validation of a new low-cost method for determining occurrence and duration of combined sewer overflows

被引:20
|
作者
Montserrat, A. [1 ]
Gutierrez, O. [1 ]
Poch, M. [1 ,2 ]
Corominas, Ll [1 ]
机构
[1] Univ Girona, Catalan Inst Water Res, Girona 17003, Spain
[2] Univ Girona, Lab Chem & Environm Engn LEQUIA, Girona 17003, Spain
关键词
CSO; Monitoring; Sewer system; Temperature; Wastewater; CSS; WASTE-WATER; RIVER; IMPACT; QUALITY; SYSTEMS; EVENT;
D O I
10.1016/j.scitotenv.2013.06.010
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Combined sewer overflow (CSO) events produced in combined sewer systems (CSS) during wet weather conditions are a threat for the receiving water bodies. The large number of CSO structures normally present in a CSS makes that the monitoring of the complete CSO network in a simultaneous way would drastically increase the investment costs. In this paper, a new methodology is presented aiming to characterize the occurrence and duration of CSO events by means of low-cost temperature sensors. Hence, a large number of CSO structures can be simultaneously monitored and the system can be characterized as a whole. The method assumes temperature differences between the overflowing mix of wastewater and stormwater and the sewer gas phase, so the temperature shift produced during a rainfall episode is related to a CSO event occurrence. The method has been tested and validated in La Garriga CSS (Spain) where the temperature at 13 CSO weirs was monitored for a period of 1 year (57 rainfall episodes). For the whole set of CSO events, occurrence and duration were successfully determined in 80% of cases. Advantages, limitations and potential applications of the method are discussed at the end of the paper. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:904 / 912
页数:9
相关论文
共 50 条
  • [1] A robust and accurate surrogate method for monitoring the frequency and duration of combined sewer overflows
    Thomas Hofer
    Albert Montserrat
    Guenter Gruber
    Valentin Gamerith
    Lluis Corominas
    Dirk Muschalla
    Environmental Monitoring and Assessment, 2018, 190
  • [2] A robust and accurate surrogate method for monitoring the frequency and duration of combined sewer overflows
    Hofer, Thomas
    Montserrat, Albert
    Gruber, Guenter
    Gamerith, Valentin
    Corominas, Lluis
    Muschalla, Dirk
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2018, 190 (04)
  • [3] A, green, low-cost method for determining sulphonamides in milk
    Furusawa, N
    Kishida, K
    LC GC EUROPE, 2005, 18 (11) : 600 - +
  • [4] LIDAR simulation method for low-cost repetitive validation
    Lee, Seongjo
    Kang, Dahyeon
    Cho, Seoungjae
    Sim, Sungdae
    Park, Yong Woon
    Um, Kyhyun
    Cho, Kyungeun
    Lecture Notes in Electrical Engineering, 2015, 373 : 237 - 242
  • [5] A LOW-COST AND ROBUST PHOTOGRAMMETRY METHOD FOR DETERMINING ELECTRODE POSITIONS
    von Ellenrieder, N.
    Beltrachini, L.
    Blenkmann, A.
    Fernandez-Corazza, M.
    Kochen, S.
    Muravchik, C. H.
    EPILEPSIA, 2013, 54 : 359 - 360
  • [6] New Method for Low-Cost Titanium Production
    Martinez, Ana Maria
    Osen, Karen Sende
    Skybakmoen, Egil
    Kjos, Ole Sigmund
    Haarberg, Geir Martin
    Dring, Kevin
    COST-AFFORDABLE TITANIUM III, 2010, 436 : 41 - +
  • [7] A Simple, Low-Cost Method to Monitor Duration of Ground Water Pumping
    Massuel, S.
    Perrin, J.
    Wajid, M.
    Mascre, C.
    Dewandel, B.
    GROUND WATER, 2009, 47 (01) : 141 - 145
  • [8] A CONVENIENT, LOW-COST METHOD FOR DETERMINING SULFATE IN ACID-RAIN
    JOHNS, N
    LONGSTAFF, SJ
    JOURNAL OF CHEMICAL EDUCATION, 1987, 64 (05) : 449 - 451
  • [9] SIMPLE AND LOW-COST FIELD METHOD FOR CHLORIDE MEASUREMENT IN WATER
    VANOORT, WJ
    GIPON, L
    BOGNAR, C
    VANHEYST, JG
    FRINTROP, PC
    GRIEPINK, B
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1974, 270 (03): : 200 - 203
  • [10] Using low-cost GPS receivers for determining field position of mechanized irrigation systems
    Peters, RT
    Evett, SR
    APPLIED ENGINEERING IN AGRICULTURE, 2005, 21 (05) : 841 - 845