A robust and accurate surrogate method for monitoring the frequency and duration of combined sewer overflows

被引:13
|
作者
Hofer, Thomas [1 ]
Montserrat, Albert [2 ]
Gruber, Guenter [1 ]
Gamerith, Valentin [1 ,3 ]
Corominas, Lluis [2 ]
Muschalla, Dirk [1 ]
机构
[1] Graz Univ Technol, Inst Urban Water Management & Landscape Water Eng, Stremayrgasse 10-I, A-8010 Graz, Austria
[2] Univ Girona, Catalan Inst Water Res Sci & Technol Pk, H2O Bldg,Emili Grahit 101, Girona 17003, Spain
[3] Hydroconsult GmbH, Engn Co Environm Engn & Water Management, St Veiter Str 11a, A-8045 Graz, Austria
关键词
Combined sewer overflow; Event detection; Low-cost; Monitoring; Temperature; Surrogate measurement; VALIDATION; LOADS;
D O I
10.1007/s10661-018-6589-3
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Discharges of untreated wastewater from combined sewer overflows (CSOs) can affect hydraulic stress and have significant environmental impacts on receiving water bodies. Common flow rate and water level sensors for monitoring of CSO events are expensive in terms of investment costs, installation, operation and maintenance. This paper presents a novel surrogate method to detect CSO events by using two low-cost temperature sensors. The novelty is the experimental setup for installation of temperature sensors in CSO structures and an algorithm developed to automatically calculate the duration of CSO events considering the response time of the system. The occurrence and duration of CSO events is computed based on the convergence of the two temperature signals. The method was tested under field conditions in a CSO structure, and the results were compared to the information gathered from a parallel installed flow sensor. The application of two temperature sensors installed inside a CSO structure was proven to be robust and accurate for the automatic detection of the occurrence and duration of CSO events. Within the 7-month test phase, 100% of the 20 CSO events could be detected without false detections. The accuracy of detecting the start and end of the CSO events was 2 min in comparison to the flow sensor.
引用
收藏
页数:18
相关论文
共 25 条
  • [21] Accurate and efficient identification of cable natural frequencies for cable tension monitoring by vibration frequency method
    Liu, Lin
    Chen, Weimin
    Zhang, Peng
    Hu, Shunren
    Luo, Wei
    SEVENTH INTERNATIONAL SYMPOSIUM ON PRECISION ENGINEERING MEASUREMENTS AND INSTRUMENTATION, 2011, 8321
  • [22] Development of a method of robust rain gauge network optimization based on intensity-duration-frequency results
    Chebbi, A.
    Bargaoui, Z. K.
    da Conceicao Cunha, M.
    HYDROLOGY AND EARTH SYSTEM SCIENCES, 2013, 17 (10) : 4259 - 4268
  • [23] An accurate and robust monitoring method of full-bridge traffic load distribution based on YOLO-v3 machine vision
    Ge, Liangfu
    Dan, Danhui
    Li, Hui
    STRUCTURAL CONTROL & HEALTH MONITORING, 2020, 27 (12):
  • [24] ACCURATE RAPID COMPACT ANALOG METHOD FOR THE QUANTIFICATION OF FREQUENCY AND DURATION OF MYOCARDIAL ISCHEMIA BY SEMIAUTOMATED ANALYSIS OF 24-HOUR HOLTER ECG RECORDINGS
    NADEMANEE, K
    SINGH, BN
    GUERRERO, J
    HENDRICKSON, J
    INTARACHOT, V
    BAKY, S
    AMERICAN HEART JOURNAL, 1982, 103 (05) : 802 - 813
  • [25] A robust and accurate discrete Fourier transform-based phasor estimation method for frequency domain fault location of power transmission lines
    Liang, Yuansheng
    Zhang, Zihong
    Li, Haifeng
    Ding, Jiayan
    Wang, Gang
    Chen, Lixin
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2022, 16 (10) : 1990 - 2002