Optimal Level of Continuous Positive Airway Pressure: Auto-adjusting Titration Versus Titration With a Predictive Equation

被引:3
|
作者
Choi, Ji Ho [1 ]
Jun, Young Joon [1 ]
Oh, Jeong In [1 ]
Jung, Jong Yoon [1 ]
Hwang, Gyu Ho [1 ]
Kwon, Soon Young [1 ]
Lee, Heung Man [1 ]
Kim, Tae Hoon [1 ]
Lee, Sang Hag [1 ]
Lee, Seung Hoon [1 ]
机构
[1] Korea Univ, Coll Med, Dept Otorhinolaryngol Head & Neck Surg, Seoul 136705, South Korea
来源
关键词
adult; body mass index; continuous positive airway pressure; obstructive sleep apnea syndrome; polysomnography; OBSTRUCTIVE SLEEP-APNEA; PRACTICE PARAMETERS; THERAPY;
D O I
10.1177/000348941312200509
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objectives: The aims of the present study were twofold. We sought to compare two methods of titrating the level of continuous positive airway pressure (CPAP) - auto-adjusting titration and titration using a predictive equation with full-night manual titration used as the benchmark. We also investigated the reliability of the two methods in patients with obstructive sleep apnea syndrome (OSAS). Methods: Twenty consecutive adult patients with OSAS who had successful, full-night manual and auto-adjusting CPAP titration participated in this study. The titration pressure level was calculated with a previously developed predictive equation based on body mass index and apnea-hypopnea index. Results: The mean titration pressure levels obtained with the manual, auto-adjusting, and predictive equation methods were 9.0 +/- 3.6, 9.4 +/- 3.0, and 8.1 +/- 1.6 cm H2O, respectively. There was a significant difference in the concordance within the range of +/- 2 cm H2O (p = 0.019) between both the auto-adjusting titration and the titration using the predictive equation compared to the full-night manual titration. However, there was no significant difference in the concordance within the range of 1 cm H2O (p > 0.999). Conclusions: When compared to full-night manual titration as the standard method, auto-adjusting titration appears to be more reliable than using a predictive equation for determining the optimal CPAP level in patients with OSAS.
引用
收藏
页码:339 / 343
页数:5
相关论文
共 50 条
  • [41] There is no difference in the adherence of continuous positive airway pressure (CPAP) therapy for obstructive sleep apnoea syndrome among the auto-adjusting CPAP machines
    Yaegashi, H.
    JOURNAL OF SLEEP RESEARCH, 2012, 21 : 343 - 344
  • [42] Factors Affecting Optimal Titration Pressure of Continuous Positive Airway Pressure Device in Patients with Obstructive Sleep Apnea Syndrome
    Kirgezen, Tolga
    Bilici, Suat
    Cakir, Mustafa
    Ceyran, Ozlem
    Chasan, Moustafa
    Yigit, Ozgur
    TURKISH ARCHIVES OF OTORHINOLARYNGOLOGY, 2020, 58 (02) : 80 - 86
  • [43] Automatic titration and calculation by predictive equations for the determination of therapeutic continuous positive airway pressure for obstructive sleep apnea
    Marrone, Oreste
    Salvaggio, Adriana
    Romano, Salvatore
    Insalaco, Giuseppe
    CHEST, 2008, 133 (03) : 670 - 676
  • [44] Daytime leg pain after overnight continuous positive airway pressure titration
    Li, Yun
    Li, Zhe
    Lei, Fei
    Zhou, Junying
    Tang, Xiangdong
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2014, 336 (1-2) : 281 - 283
  • [45] Psychiatric Disorder Does Not Preclude Adequate Continuous Positive Airway Pressure Titration
    Manjunath, Skantha K.
    Sarva, Siva T.
    Yataco, Jose C.
    Murillo, Luis C.
    Avecillas, Jaime F.
    Freire, Amado X.
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2013, 346 (02): : 104 - 107
  • [46] TITRATION OF CONTINUOUS POSITIVE AIRWAY PRESSURE BY REAL-TIME DUAL OXIMETRY
    RASANEN, J
    DOWNS, JB
    DEHAVEN, B
    CHEST, 1987, 92 (05) : 853 - 856
  • [47] Nonattended home automated continuous positive airway pressure titration: Comparison with polysomnography
    Woodson, BT
    Saurejan, A
    Brusky, LT
    Han, JK
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2003, 128 (03) : 353 - 357
  • [48] HYPOXIA INDUCED SUPRAVENTRICULAR TACHYCARDIA, RESOLVED WITH CONTINUOUS POSITIVE AIRWAY PRESSURE TITRATION
    Ramaniuk, Aliaksandr.
    Dalal, L.
    Galluci, S.
    Ricaurte, Basma
    SLEEP, 2019, 42 : A415 - A415
  • [49] TITRATION OF CONTINUOUS POSITIVE AIRWAY PRESSURE BY REAL-TIME DUAL OXIMETRY
    RASANEN, J
    DOWNS, JB
    DEHAVEN, B
    CRITICAL CARE MEDICINE, 1987, 15 (04) : 395 - 395
  • [50] Automatic nasal continuous positive airway pressure titration in the laboratory: Patient outcomes
    Stradling, JR
    Barbour, C
    Pitson, DJ
    Davies, RJO
    THORAX, 1997, 52 (01) : 72 - 75