Optimal Level of Continuous Positive Airway Pressure: Auto-adjusting Titration Versus Titration With a Predictive Equation

被引:3
|
作者
Choi, Ji Ho [1 ]
Jun, Young Joon [1 ]
Oh, Jeong In [1 ]
Jung, Jong Yoon [1 ]
Hwang, Gyu Ho [1 ]
Kwon, Soon Young [1 ]
Lee, Heung Man [1 ]
Kim, Tae Hoon [1 ]
Lee, Sang Hag [1 ]
Lee, Seung Hoon [1 ]
机构
[1] Korea Univ, Coll Med, Dept Otorhinolaryngol Head & Neck Surg, Seoul 136705, South Korea
来源
关键词
adult; body mass index; continuous positive airway pressure; obstructive sleep apnea syndrome; polysomnography; OBSTRUCTIVE SLEEP-APNEA; PRACTICE PARAMETERS; THERAPY;
D O I
10.1177/000348941312200509
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objectives: The aims of the present study were twofold. We sought to compare two methods of titrating the level of continuous positive airway pressure (CPAP) - auto-adjusting titration and titration using a predictive equation with full-night manual titration used as the benchmark. We also investigated the reliability of the two methods in patients with obstructive sleep apnea syndrome (OSAS). Methods: Twenty consecutive adult patients with OSAS who had successful, full-night manual and auto-adjusting CPAP titration participated in this study. The titration pressure level was calculated with a previously developed predictive equation based on body mass index and apnea-hypopnea index. Results: The mean titration pressure levels obtained with the manual, auto-adjusting, and predictive equation methods were 9.0 +/- 3.6, 9.4 +/- 3.0, and 8.1 +/- 1.6 cm H2O, respectively. There was a significant difference in the concordance within the range of +/- 2 cm H2O (p = 0.019) between both the auto-adjusting titration and the titration using the predictive equation compared to the full-night manual titration. However, there was no significant difference in the concordance within the range of 1 cm H2O (p > 0.999). Conclusions: When compared to full-night manual titration as the standard method, auto-adjusting titration appears to be more reliable than using a predictive equation for determining the optimal CPAP level in patients with OSAS.
引用
收藏
页码:339 / 343
页数:5
相关论文
共 50 条
  • [21] Continuous positive airway pressure titration: Manual, automatic, or empirical?
    Masa, JF
    ARCHIVOS DE BRONCONEUMOLOGIA, 2004, 40 (04): : 147 - 148
  • [22] The effects of heated humidifier in continuous positive airway pressure titration
    Chung-Chieh Yu
    Cheng-Ming Luo
    Yu-Chih Liu
    Huang-Pin Wu
    Sleep and Breathing, 2013, 17 : 133 - 138
  • [23] Utility of prediction algorithm for continuous positive airway pressure titration
    Djekidel, Karim
    Parashar, Anushree
    Sharma, Vinay
    Pai, Vosudesh
    Rahmouni, Hind
    Dubey, Aditya N.
    Haber, Alan D.
    CHEST, 2007, 132 (04) : 665S - 665S
  • [24] The effects of heated humidifier in continuous positive airway pressure titration
    Yu, Chung-Chieh
    Luo, Cheng-Ming
    Liu, Yu-Chih
    Wu, Huang-Pin
    SLEEP AND BREATHING, 2013, 17 (01) : 133 - 138
  • [25] Flexible positive airway pressure improves treatment adherence compared with auto-adjusting PAP
    Chihara, Yuichi
    Tsuboi, Tomomasa
    Hitomi, Takefumi
    Azuma, Masanori
    Murase, Kimihiko
    Toyama, Yoshiro
    Harada, Yuka
    Aihara, Kensaku
    Tanizawa, Kiminobu
    Handa, Tomohiro
    Yoshimura, Chikara
    Oga, Toru
    Yamamoto, Kazuhiko
    Mishima, Michiaki
    Chin, Kazuo
    EUROPEAN RESPIRATORY JOURNAL, 2012, 40
  • [26] Comparison of conventional continuous positive airway pressure to continuous positive airway pressure titration performed with sleep endoscopy
    Civelek, Senol
    Emre, Ismet Emrah
    Dizdar, Denizhan
    Cuhadaroglu, Caglar
    Eksioglu, Birsen Karaci
    Eraslan, Algin Kayar
    Turgut, Suat
    LARYNGOSCOPE, 2012, 122 (03): : 691 - 695
  • [27] Reducing upper airway collapse at lower continuous positive airway titration pressure
    Ashaat, Sherif
    Al-Jumaily, Ahmed M.
    JOURNAL OF BIOMECHANICS, 2016, 49 (16) : 3915 - 3922
  • [28] Auto-adjusting positive airway pressure therapy in sickle cell anaemia children: Pilot study
    Marshall, M. J.
    Kirkham, F. J.
    Hogan, A. M.
    Rees, D. C.
    Bucks, R. S.
    SLEEP, 2008, 31 : A63 - A63
  • [29] Auto-Adjustable Positive Airway Pressure Versus Polysomnographic Titration In Childhood Obstructive Sleep Apnea
    Opasatian, R.
    Preutthipan, A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195
  • [30] Auto-adjusting Positive Airway Pressure Treatment for Sleep Apnea Diagnosed by Home Sleep Testing
    Berry, Richard B.
    Sriram, Peruvemba
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2014, 10 (12): : 1269 - 1275