Optimal Level of Continuous Positive Airway Pressure: Auto-adjusting Titration Versus Titration With a Predictive Equation

被引:3
|
作者
Choi, Ji Ho [1 ]
Jun, Young Joon [1 ]
Oh, Jeong In [1 ]
Jung, Jong Yoon [1 ]
Hwang, Gyu Ho [1 ]
Kwon, Soon Young [1 ]
Lee, Heung Man [1 ]
Kim, Tae Hoon [1 ]
Lee, Sang Hag [1 ]
Lee, Seung Hoon [1 ]
机构
[1] Korea Univ, Coll Med, Dept Otorhinolaryngol Head & Neck Surg, Seoul 136705, South Korea
来源
关键词
adult; body mass index; continuous positive airway pressure; obstructive sleep apnea syndrome; polysomnography; OBSTRUCTIVE SLEEP-APNEA; PRACTICE PARAMETERS; THERAPY;
D O I
10.1177/000348941312200509
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objectives: The aims of the present study were twofold. We sought to compare two methods of titrating the level of continuous positive airway pressure (CPAP) - auto-adjusting titration and titration using a predictive equation with full-night manual titration used as the benchmark. We also investigated the reliability of the two methods in patients with obstructive sleep apnea syndrome (OSAS). Methods: Twenty consecutive adult patients with OSAS who had successful, full-night manual and auto-adjusting CPAP titration participated in this study. The titration pressure level was calculated with a previously developed predictive equation based on body mass index and apnea-hypopnea index. Results: The mean titration pressure levels obtained with the manual, auto-adjusting, and predictive equation methods were 9.0 +/- 3.6, 9.4 +/- 3.0, and 8.1 +/- 1.6 cm H2O, respectively. There was a significant difference in the concordance within the range of +/- 2 cm H2O (p = 0.019) between both the auto-adjusting titration and the titration using the predictive equation compared to the full-night manual titration. However, there was no significant difference in the concordance within the range of 1 cm H2O (p > 0.999). Conclusions: When compared to full-night manual titration as the standard method, auto-adjusting titration appears to be more reliable than using a predictive equation for determining the optimal CPAP level in patients with OSAS.
引用
收藏
页码:339 / 343
页数:5
相关论文
共 50 条
  • [31] The effect of continuous positive airway pressure titration on blood pressure in obese subjects
    Ratneswaran, Culadeeban
    Pengo, Martino
    Xiao, Sichang
    Bastianpillai, Johan
    Luo, Yuanming
    Khong, Teck
    Steier, Joerg
    EUROPEAN RESPIRATORY JOURNAL, 2015, 46
  • [32] Titration with automatic continuous positive airway pressure in obstructive steep apnea
    Dias, C.
    Sousa, L.
    Batata, L.
    Reis, R.
    Teixeira, F.
    Moita, J.
    Moutinho dos Santos, J.
    REVISTA PORTUGUESA DE PNEUMOLOGIA, 2017, 23 (04) : 203 - 207
  • [33] Sleep during titration predicts continuous positive airway pressure compliance
    Drake, CL
    Day, R
    Hudgel, D
    Stefadu, Y
    Parks, M
    Syron, ML
    Roth, T
    SLEEP, 2003, 26 (03) : 308 - 311
  • [34] Pulse wave analysis in a pilot randomised controlled trial of auto-adjusting and continuous positive airway pressure for obstructive sleep apnoea
    Jessie P. Bakker
    Angela J. Campbell
    Alister M. Neill
    Sleep and Breathing, 2011, 15 : 325 - 332
  • [35] Factors That Affect Auto-Continuous Positive Airway Pressure Level Designated During Titration Night in Patients with Obstructive Sleep Apnoea
    Salepci, Banu
    Parmaksiz, Elif Torun
    Kiral, Nesrin
    Sarac, Gulsen
    Comert, Sevda Sener
    Fidan, Ali
    Caglayan, Benan
    TURKISH THORACIC JOURNAL, 2014, 15 (02) : 57 - 60
  • [36] Pulse wave analysis in a pilot randomised controlled trial of auto-adjusting and continuous positive airway pressure for obstructive sleep apnoea
    Bakker, Jessie P.
    Campbell, Angela J.
    Neill, Alister M.
    SLEEP AND BREATHING, 2011, 15 (03) : 325 - 332
  • [37] Objective Approach for Titration of Continuous Positive Airway Pressure in Patients with Obstructive Sleep Apnea Using Daytime Continuous Positive Airway Pressure Titration Based on Respiratory Movement Regularity
    Burioka, Naoto
    Hirayama, Yuki
    Endo, Masahiro
    Oguri, Masayoshi
    Takata, Miyako
    Ikeuchi, Tomoyuki
    Yamasaki, Akira
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (24)
  • [38] NightBalance Sleep Position Treatment Device Versus Auto-Adjusting Positive Airway Pressure for Treatment of Positional Obstructive Sleep Apnea
    Berry, Richard B.
    Uhles, Matthew L.
    Abaluck, Brian K.
    Winslow, David H.
    Schweitzer, Paula K.
    Gaskins, Raymond A., Jr.
    Doekel, Robert C., Jr.
    Emsellem, Helene A.
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2019, 15 (07): : 947 - 956
  • [39] Auto-adjusting versus fixed positive pressure therapy in mild to moderate obstructive sleep apnoea
    Nolan, Geraldine M.
    Doherty, Liam S.
    Mc Nicholas, Walter T.
    SLEEP, 2007, 30 (02) : 189 - 194
  • [40] A CASE OF UNSUCCESSFUL POSITIVE AIRWAY PRESSURE TITRATION
    Walia, Neal
    Chang, Melisa
    Zeidler, Michelle
    SLEEP, 2024, 47