Optimal Level of Continuous Positive Airway Pressure: Auto-adjusting Titration Versus Titration With a Predictive Equation

被引:3
|
作者
Choi, Ji Ho [1 ]
Jun, Young Joon [1 ]
Oh, Jeong In [1 ]
Jung, Jong Yoon [1 ]
Hwang, Gyu Ho [1 ]
Kwon, Soon Young [1 ]
Lee, Heung Man [1 ]
Kim, Tae Hoon [1 ]
Lee, Sang Hag [1 ]
Lee, Seung Hoon [1 ]
机构
[1] Korea Univ, Coll Med, Dept Otorhinolaryngol Head & Neck Surg, Seoul 136705, South Korea
来源
关键词
adult; body mass index; continuous positive airway pressure; obstructive sleep apnea syndrome; polysomnography; OBSTRUCTIVE SLEEP-APNEA; PRACTICE PARAMETERS; THERAPY;
D O I
10.1177/000348941312200509
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objectives: The aims of the present study were twofold. We sought to compare two methods of titrating the level of continuous positive airway pressure (CPAP) - auto-adjusting titration and titration using a predictive equation with full-night manual titration used as the benchmark. We also investigated the reliability of the two methods in patients with obstructive sleep apnea syndrome (OSAS). Methods: Twenty consecutive adult patients with OSAS who had successful, full-night manual and auto-adjusting CPAP titration participated in this study. The titration pressure level was calculated with a previously developed predictive equation based on body mass index and apnea-hypopnea index. Results: The mean titration pressure levels obtained with the manual, auto-adjusting, and predictive equation methods were 9.0 +/- 3.6, 9.4 +/- 3.0, and 8.1 +/- 1.6 cm H2O, respectively. There was a significant difference in the concordance within the range of +/- 2 cm H2O (p = 0.019) between both the auto-adjusting titration and the titration using the predictive equation compared to the full-night manual titration. However, there was no significant difference in the concordance within the range of 1 cm H2O (p > 0.999). Conclusions: When compared to full-night manual titration as the standard method, auto-adjusting titration appears to be more reliable than using a predictive equation for determining the optimal CPAP level in patients with OSAS.
引用
收藏
页码:339 / 343
页数:5
相关论文
共 50 条
  • [1] Nasal versus oronasal mask in patients under auto-adjusting continuous positive airway pressure titration: a real-life study
    Ricardo L. M. Duarte
    Bruno A. Mendes
    Tiago S. Oliveira-e-Sá
    Flavio J. Magalhães-da-Silveira
    David Gozal
    European Archives of Oto-Rhino-Laryngology, 2020, 277 : 3507 - 3512
  • [2] Nasal versus oronasal mask in patients under auto-adjusting continuous positive airway pressure titration: a real-life study
    Duarte, Ricardo L. M.
    Mendes, Bruno A.
    Oliveira-e-Sa, Tiago S.
    Magalhaes-da-Silveira, Flavio J.
    Gozal, David
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2020, 277 (12) : 3507 - 3512
  • [3] ESTABLISHING A PREDICTIVE EQUATION FOR AUTO-ADJUSTING TITRATION IN OSAS PATIENTS USING ANATOMICAL AND POLYSOMNOGRAPHIC PARAMETERS
    Noh, Y.
    SLEEP MEDICINE, 2019, 64 : S281 - S282
  • [4] Accuracy of positive airway pressure titration through telemonitoring of auto-adjusting positive airway pressure device connected to a pulse oximetry in patients with obstructive sleep apnea
    Foresi, Antonio
    Vitale, Tommaso
    Prestigiacomo, Rosaria
    Ranieri, Piera
    Bosi, Marcello
    CLINICAL RESPIRATORY JOURNAL, 2023, 17 (08): : 740 - 747
  • [5] Bench testing of auto-adjusting positive airway pressure devices
    Abdenbi, F
    Chambille, B
    Escourrou, P
    EUROPEAN RESPIRATORY JOURNAL, 2004, 24 (04) : 649 - 658
  • [6] Auto-adjusting and Advanced Positive Airway Pressure Therapeutic Modalities
    Ryden, Armand
    Bando, Joanne M.
    Aysola, Ravi S.
    SEMINARS IN RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 35 (05) : 593 - 603
  • [7] Continuous positive airway pressure titration for obstructive sleep apnoea: automatic versus manual titration
    McArdle, Nigel
    Singh, Bhajan
    Murphy, Michelle
    Gain, Kevin R.
    Maguire, Christine
    Mutch, Sarah
    Hillman, David R.
    THORAX, 2010, 65 (07) : 606 - 611
  • [8] THE RESOLUTION OF VENTRICULAR TACHYCARDIA WITH OPTIMAL CONTINUOUS POSITIVE AIRWAY PRESSURE TITRATION
    Al-Sharif, Hussam Z.
    Jones, Kellie R.
    SLEEP, 2018, 41 : A420 - A420
  • [9] EFFECT OF AUTO-TITRATION ON COMPLIANCE WITH CONTINUOUS POSITIVE AIRWAY PRESSURE (CPAP)
    Milite, F. M.
    Wisnivesky, J.
    SLEEP, 2011, 34 : A137 - A138
  • [10] Comparison of manual versus automatic continuous positive airway pressure titration and the development of a predictive equation for therapeutic continuous positive airway pressure in Chinese patients with obstructive sleep apnoea
    Luo, Jiaying
    Xiao, Sichang
    Qiu, Zhihui
    Song, Ning
    Luo, Yuanming
    RESPIROLOGY, 2013, 18 (03) : 528 - 533