Blasting Demolition Technology and Vibration Testing of 210m Reinforced Concrete Chimney

被引:0
|
作者
Xu, Shunxiang [1 ,3 ]
Chen, Dezhi [2 ,3 ]
机构
[1] Wuhan Univ Sci & Technol, Wuhan 430081, Peoples R China
[2] Wuhan Safety & Environm Protect Res Inst, Wuhan 430081, Peoples R China
[3] Wuhan Univ Technol, Wuhan 430070, Peoples R China
关键词
Chimney; Directional blasting; Electronic digital detonator; Overlarge oriented window; comprehensive protection;
D O I
10.4028/www.scientific.net/AMM.226-228.986
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper describes the successful experience of the directional control blasting of 210m-high reinforced concrete chimney of Nanchang Power Plant in Jiangxi Province called as "First height in Asia". It emphatically describes the pretreatment measures, blasting cut shape and size, blasting parameters, electronic digital detonator detonating network and blasting safety technology. And the blasting vibration was tested and analyzed, and this paper presents the method for opening the arch overlarge oriented window and comprehensive protection method for anti-flyrock splash, vibration reduction and dustfall. Especially, the electronic digital detonator was first applied in the blasting demolition of 210m-high structures, it improves the delay precision and also has a good anti-stray current effect to ensure that the blasting can be safely implemented in the power plant, and it has a good application prospect in the future large-scale and high level complex engineering blasting.
引用
收藏
页码:986 / +
页数:2
相关论文
共 45 条
  • [41] Full-scale reinforced concrete bridge bent condition assessment using forced-vibration testing
    Achter, JL
    Halling, MW
    Womack, KC
    NONDESTRUCTIVE EVALUATION OF HIGHWAYS, UTILITIES, AND PIPELINES IV, 2000, 3995 : 396 - 403
  • [42] Load Rating of a Reinforced Concrete T-Beam Bridge Through Ambient Vibration Testing and Finite Element Model Updating
    Ndong, Abdou K.
    Dizaji, Mehrdad S.
    Alipour, Mohamad
    Ozbulut, Osman E.
    Harris, Devin K.
    DYNAMICS OF CIVIL STRUCTURES, VOL 2, 2019, : 337 - 343
  • [43] Forced Vibration Testing of a Four-Story Reinforced Concrete Building Utilizing the nees@UCLA Mobile Field Laboratory
    Yu, Eunjong
    Skolnik, Derek
    Whang, Daniel H.
    Wallace, John W.
    EARTHQUAKE SPECTRA, 2008, 24 (04) : 969 - 995
  • [44] Forced Vibration Testing and Finite Element Modeling of a Nine-Story Reinforced Concrete Flat Plate-Wall Building
    Celik, Ozan Cem
    Sucuoglu, Haluk
    Akyuz, Ugurhan
    EARTHQUAKE SPECTRA, 2015, 31 (02) : 1069 - 1081
  • [45] Magnetic force induced vibration evaluation (M5) method for frequency analysis of rebar-debonding in reinforced concrete
    Frankowski, Pawel Karol
    Chady, Tomasz
    Zielinski, Adam
    MEASUREMENT, 2021, 182