Forced Vibration Testing of a Four-Story Reinforced Concrete Building Utilizing the nees@UCLA Mobile Field Laboratory

被引:22
|
作者
Yu, Eunjong [1 ]
Skolnik, Derek [2 ]
Whang, Daniel H.
Wallace, John W. [2 ]
机构
[1] Hanyang Univ, Dept Architectural Engn, Seoul 133791, South Korea
[2] Univ Calif Los Angeles, Dept Civil & Environm Engn, Los Angeles, CA 90095 USA
基金
美国国家科学基金会;
关键词
accelerometers; building; concrete; dynamic testing; earthquake engineering; earthquakes; vibrations;
D O I
10.1193/1.2991300
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The nees@UCLA mobile field laboratory was utilized to collect forced and ambient vibration data from a four-story reinforced concrete (RC) building damaged in the 1994 Northridge earthquake. Both low amplitude broadband and moderate amplitude harmonic excitation were applied using a linear shaker and two eccentric mass shakers, respectively. Floor accelerations, interstory displacements, and column and slab curvature distributions were monitored during the tests using accelerometers, linear variable differential transformers (LVDTs) and concrete strain gauges. The use of dense instrumentation enabled verification of common modeling assumptions related to rigid diaphragms and soil-structure-interaction. The first six or seven natural frequencies, mode shapes, and damping ratios were identified. Significant decreases in frequency corresponded to increases in shaking amplitude, most notably in the N-S direction of the building, most likely due to preexisting diagonal joint cracks that formed during the Northridge earthquake.
引用
收藏
页码:969 / 995
页数:27
相关论文
共 10 条
  • [1] Forced-Vibration Tests of a Reinforced Concrete Four-Story Building Structure
    De-la-Colina, Jaime
    Valdes-Gonzalez, Jesus
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2021, 147 (07)
  • [2] AMBIENT VIBRATION RECORDS IN REPRODUCING THE FORCED VIBRATION TEST RESULTS OF A FOUR-STORY REINFORCED CONCRETE BUILDING WITH TWO BASEMENT FLOORS
    Celik, Ozan Cem
    [J]. 6TH IOMAC: INTERNATIONAL OPERATIONAL MODAL ANALYSIS CONFERENCE PROCEEDINGS, 2015, : 513 - 519
  • [3] Modal identification of a four-story reinforced concrete building under renovation by using ambient vibration measurement
    Areemit, N
    Yamaguchi, H
    Matsumoto, Y
    Ibi, T
    [J]. STRUCTURAL HEALTH MONITORING AND INTELLIGENT INFRASTRUCTURE, VOLS 1 AND 2, 2003, : 513 - 520
  • [4] FORCED VIBRATION OF AN 8-STORY REINFORCED CONCRETE BUILDING
    ENGLEKIRK, RE
    MATTHIES.RB
    [J]. BULLETIN OF THE SEISMOLOGICAL SOCIETY OF AMERICA, 1967, 57 (03) : 421 - +
  • [5] Design Implications of Large-Scale Shake-Table Test on Four-Story Reinforced Concrete Building
    Nagae, T.
    Ghannoum, W. M.
    Kwon, J.
    Tahara, K.
    Fukuyama, K.
    Matsumori, T.
    Shiohara, H.
    Kabeyasawa, T.
    Kono, S.
    Nishiyama, M.
    Sause, R.
    Wallace, J. W.
    Moehle, J. P.
    [J]. ACI STRUCTURAL JOURNAL, 2015, 112 (02) : 135 - 146
  • [6] Forced Vibration Testing and Finite Element Modeling of a Nine-Story Reinforced Concrete Flat Plate-Wall Building
    Celik, Ozan Cem
    Sucuoglu, Haluk
    Akyuz, Ugurhan
    [J]. EARTHQUAKE SPECTRA, 2015, 31 (02) : 1069 - 1081
  • [7] Dynamic behaviour of a 13-story reinforced concrete building under ambient vibration, forced vibration, and earthquake excitation
    Beskhyroun, Sherif
    Navabian, Niusha
    Wotherspoon, Liam
    Ma, Quincy
    [J]. JOURNAL OF BUILDING ENGINEERING, 2020, 28
  • [8] Ambient and Forced Vibration Testing of a Reinforced Concrete Building before and after Its Seismic Retrofitting
    Soyoz, Serdar
    Taciroglu, Ertugrul
    Orakcal, Kutay
    Nigbor, Robert
    Skolnik, Derek
    Lus, Hilmi
    Safak, Erdal
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2013, 139 (10) : 1741 - 1752
  • [9] Modal Analysis of a Full-scale Four-story Reinforced-concrete Base-isolated Building Subjected to Random and Simulated Earthquake Shake Table Excitations
    Brewick, Patrick T.
    Hernandez, Jessica Barrios
    Elhaddad, Wael M.
    Johnson, Erik A.
    Christenson, Richard E.
    Sato, Eiki
    [J]. STRUCTURAL HEALTH MONITORING 2015: SYSTEM RELIABILITY FOR VERIFICATION AND IMPLEMENTATION, VOLS. 1 AND 2, 2015, : 1328 - 1335
  • [10] Pseudo-dynamic and forced vibration tests of a full-size two-story reinforced high-performance concrete building
    Paultre, R
    Proulx, I
    Mousseau, S
    Prévost, T
    Savard, C
    [J]. LARGE-SCALE STRUCTURAL TESTING, 2003, 211 : 135 - 160