Partial discharge characteristics of interturn insulation used for inverter-fed traction motor under bipolar impulses

被引:8
|
作者
Wu GuangNing [1 ]
Cao KaiJiang [1 ]
Luo Yang [1 ]
Gao Bo [1 ]
Wang Peng [1 ]
Zhang YiQiang [1 ]
Xu HuiHui [1 ]
机构
[1] SW Jiaotong Univ, Sch Elect Engn, Chengdu 610031, Peoples R China
基金
中国国家自然科学基金;
关键词
partial discharges; bipolar impulse; interturn insulation; electric-multiple-units; memory effect; space charges; VOLTAGE; MECHANISM; MACHINES; CAVITIES;
D O I
10.1007/s11431-012-4901-y
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Inverter-fed traction motors, which are employed for electric-multiple-units (EMUs), are subjected to Pulse Width Modulated (PWM) impulse voltage. Impulse voltage has fast rise/fall time and high repetition frequency. The failure mechanism of insulation under impulses is different from that of standard 50 Hz sinusoidal condition. Partial discharge (PD) characteristics (discharge number, mean discharge quantity and phase resolved partial discharge (PRPD) pattern) with different frequencies and different rise times of impulse voltage were investigated. The results reveal that discharge number and mean discharge quantity increase, while PRPD pattern moves to the zero of impulse voltage with decrease of rise time. Discharge number and PRPD pattern follow that trend with increase of frequency, the value of mean discharge quantity is similar. Memory effect of the deposited space charges on PD was studied. PRPD pattern moves to the zero of bipolar impulse voltage due to the role of space charges, with increase of frequency and decrease of rise time. It is revealed that available discharge time is prolonged and overvoltage across the cavity increases with augment of frequency, which results in discharge number increasing. Under the condition of shortening the rise time, with the same statistical time lag t (L) , Delta V would increase if dV/dt is higher, which results in enhancement of discharge quantity. Discharge number increases with reduction of rise time, because the decreased multiple of t (d) is lower than the increased multiple of dV/dt. Study of PD characteristics and role of space charges is helpful to the exploration of the destructive mechanism of insulating materials under bipolar impulse.
引用
收藏
页码:2346 / 2354
页数:9
相关论文
共 50 条
  • [21] Partial discharge propagation and degradation characteristics of magnet wire for inverter-fed motor under surge voltage application
    Hayakawa, N.
    Inano, H.
    Inuzuka, K.
    Morikawa, M.
    Okubo, H.
    [J]. 2006 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2006, : 565 - 568
  • [22] FEASIBILITY OF PARTIAL DISCHARGE DETECTION IN INVERTER-FED ACTUATORS USED IN AIRCRAFTS
    Cavallini, A.
    Versari, L.
    Fornasari, L.
    [J]. 2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 1250 - 1253
  • [23] Study of PD behaviors on a crossed sample of magnet-wire with repetitive bipolar impulses for inverter-fed motor coil insulation
    Kimura, K
    Ushirone, S
    Koyanagi, T
    Iiyama, Y
    Ohtsuka, S
    Hikita, M
    [J]. 2005 Annual Report Conference on Electrical Insulation and Dielectric Phenomena, 2005, : 393 - 396
  • [24] Influence of Repetitive Impulse Wave Voltage Duty Cycle on Partial Discharge Statistics in Inverter-fed Motor Insulation
    Xu H.
    Zhao L.
    Wang P.
    Wang J.
    Zhou W.
    Li J.
    [J]. 2017, Chinese Society for Electrical Engineering (37): : 2159 - 2166
  • [25] Pulse width modulation voltage source deadtime effect on partial discharge and lifetime of inverter-fed motor insulation
    Akram, Shakeel
    Wang, Peng
    Meng, Pengfei
    Montanari, Gian Carlo
    Malik, Farhan Hameed
    [J]. HIGH VOLTAGE, 2022, 7 (06): : 1185 - 1193
  • [26] Deterioration of Stator Winding Insulation in Inverter-Fed Traction Motors
    Yuan, Pengfei
    Liu, Xuezhong
    Lei, Pingzhen
    Wang, Jingna
    Fan, Jiexin
    Zhang, Xiaoqiang
    Zhu, Hugh
    [J]. 2020 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2020, : 457 - 460
  • [27] Investigation on performances of insulation materials for inverter-fed traction motors
    Petrarca, C
    Egiziano, L
    Tucci, V
    Vitelli, M
    [J]. 1998 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS 1 AND 2, 1998, : 564 - 567
  • [28] Design of an Effective Antenna for Partial Discharge Detection in Insulation Systems of Inverter-fed Motors
    Wang, Peng
    Ma, Shijin
    Akram, Shakeel
    Meng, Pengfei
    Castellon, Jerome
    Li, Zongze
    Montanari, Gian Carlo
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (12) : 13727 - 13735
  • [29] Life Models of Polyimide Film under Combined Thermal and Electrical Stresses Used in Inverter-fed Traction Motor
    Cui, Yi
    Wu, Guangning
    Cao, Kaijiang
    Luo, Yang
    [J]. 2011 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS 1 AND 2, 2011, : 80 - 83
  • [30] Contribution to Partial Discharge Analysis in Inverter-fed Motor Windings for Automotive Application
    Benmamas, Loucif
    Teste, Philippe
    Krebs, Guillaume
    Odic, Emmanuel
    Vangraefschepe, Franck
    Hamiti, Tahar
    [J]. 2017 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2017, : 348 - 351