Partial discharge characteristics of interturn insulation used for inverter-fed traction motor under bipolar impulses

被引:8
|
作者
Wu GuangNing [1 ]
Cao KaiJiang [1 ]
Luo Yang [1 ]
Gao Bo [1 ]
Wang Peng [1 ]
Zhang YiQiang [1 ]
Xu HuiHui [1 ]
机构
[1] SW Jiaotong Univ, Sch Elect Engn, Chengdu 610031, Peoples R China
基金
中国国家自然科学基金;
关键词
partial discharges; bipolar impulse; interturn insulation; electric-multiple-units; memory effect; space charges; VOLTAGE; MECHANISM; MACHINES; CAVITIES;
D O I
10.1007/s11431-012-4901-y
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Inverter-fed traction motors, which are employed for electric-multiple-units (EMUs), are subjected to Pulse Width Modulated (PWM) impulse voltage. Impulse voltage has fast rise/fall time and high repetition frequency. The failure mechanism of insulation under impulses is different from that of standard 50 Hz sinusoidal condition. Partial discharge (PD) characteristics (discharge number, mean discharge quantity and phase resolved partial discharge (PRPD) pattern) with different frequencies and different rise times of impulse voltage were investigated. The results reveal that discharge number and mean discharge quantity increase, while PRPD pattern moves to the zero of impulse voltage with decrease of rise time. Discharge number and PRPD pattern follow that trend with increase of frequency, the value of mean discharge quantity is similar. Memory effect of the deposited space charges on PD was studied. PRPD pattern moves to the zero of bipolar impulse voltage due to the role of space charges, with increase of frequency and decrease of rise time. It is revealed that available discharge time is prolonged and overvoltage across the cavity increases with augment of frequency, which results in discharge number increasing. Under the condition of shortening the rise time, with the same statistical time lag t (L) , Delta V would increase if dV/dt is higher, which results in enhancement of discharge quantity. Discharge number increases with reduction of rise time, because the decreased multiple of t (d) is lower than the increased multiple of dV/dt. Study of PD characteristics and role of space charges is helpful to the exploration of the destructive mechanism of insulating materials under bipolar impulse.
引用
收藏
页码:2346 / 2354
页数:9
相关论文
共 50 条
  • [41] Partial Discharge Characteristics of Twisted Enameled Magnet Wires for Inverter-fed Random Wound Motors
    Kikuchi, Yusuke
    Miyamae, Masanori
    Fukuda, Yuki
    Nagata, Masayoshi
    Tuda, Toshihiro
    Tsutsui, Hirotsugu
    Ikegami, Tomomi
    Sakurai, Takayuki
    Yamada, Shinichiro
    Yoshimitsu, Tetsuo
    [J]. PROCEEDINGS OF 2011 INTERNATIONAL CONFERENCE ON ELECTRICAL INSULATING MATERIALS (ISEIM), 2011, : 125 - 127
  • [42] Design of Archimedes Spiral Antenna to Optimize for Partial Discharge Detection of Inverter Fed Motor Insulation
    Wang, Peng
    Ma, Shijin
    Akram, Shakeel
    Zhou, Kai
    Chen, Yidong
    Nazir, Muhammad Tariq
    [J]. IEEE ACCESS, 2020, 8 : 193202 - 193213
  • [43] Characteristic Research on the Sensor for Inter-turn Partial Discharge Measurement of Inverter-fed Motor Winding
    Yuan, Pengfei
    Liu, Xuezhong
    Zhang, Tianlong
    Liu, Ping
    [J]. 2019 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2019, : 13 - 17
  • [44] A Novel Embedded Sensor for Partial Discharge Detection in Inverter-Fed Machines
    Ogundiran, Yinka Leo
    Griffo, Antonio
    Sundeep, Shubham
    Wang, Jiabin
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (04) : 4698 - 4707
  • [45] Characteristics of PWM inverter-fed induction motor in consideration of saturation
    Kamimoto, K
    Yamada, S
    Murai, Y
    [J]. AMC '96-MIE - 1996 4TH INTERNATIONAL WORKSHOP ON ADVANCED MOTION CONTROL, PROCEEDINGS, VOLS 1 AND 2, 1996, : 174 - 179
  • [46] Multifactor Stress Life Model of Polyimide Film Used in Inverter-Fed Traction Motors
    Cui, Yi
    Wu, Guangning
    Luo, Yang
    Cao, Kaijiang
    [J]. FRONTIERS OF MANUFACTURING AND DESIGN SCIENCE II, PTS 1-6, 2012, 121-126 : 239 - 243
  • [47] Partial Discharge Inception Voltage for Magnet Wire of Inverter-fed Motors under Surge Voltage Application
    Hayakawa, Naoki
    Shimizu, Fuminobu
    Peng, Xie
    Okubo, Hitoshi
    [J]. 2010 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTIC PHENOMENA, 2010,
  • [48] Temperature Effects on PD Statistics and Endurance of Inverter-fed Motor Insulation under Repetitive Square Wave Voltages
    Wang, Peng
    Xu, Hongying
    Wang, Jian
    Cavallini, Andrea
    Montanari, Gian Carlo
    [J]. 2016 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2016, : 202 - 205
  • [49] Influence of Cable Insulation Structure on Terminal Over-voltage of Inverter-fed Motor
    Zhu Yongzhan
    Liu Xuezhong
    Gao Chao
    Deng Xianbo
    [J]. 2007 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2007, : 75 - 78
  • [50] The impact of test voltage waveform in determining the repetitive partial discharge inception voltage of Type I turn/turn insulation used in inverter-fed induction motors
    Lusuardi, Luca
    Cavallini, Andrea
    Caprara, Andrea
    Bardelli, Fabrizio
    Cattazzo, Andrea
    [J]. 2018 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2018, : 478 - 481