Effects of different inter-implant distances on the stress distribution around endosseous implants in posterior mandible: A 3D finite element analysis

被引:61
|
作者
Simsek, B
Erkmen, E
Yilmaz, D
Eser, A
机构
[1] Gazi Univ, Fac Dent, Dept Oral & Maxillofacial Surg, TR-06690 Ankara, Turkey
[2] Middle E Tech Univ, Dept Mech Engn, Ankara, Turkey
关键词
inter-implant distance; dental implant; peri-implant structure; stress distribution; 3D finite elements analysis;
D O I
10.1016/j.medengphy.2005.04.025
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: The aim of this study was to evaluate the effects of different inter-implant distances on stress distribution in the bone around the endosseous titanium implants under vertical, oblique and horizontal loads in the posterior mandibular edentulousim by finite element analysis (3D FEA). Materials and methods: 3D FEA models representing mandible and ITI (R) implant (Straumann, Waldenburg, Switzerland) were simulated. The distances in-between the units were set at 0.5, 1.0 and 2.0 cm. Vertical (V) 70 degrees N, 60 degrees oblique (BL) 35 degrees N in buccolingual direction and horizontal (MD) 14 degrees N in mesiodistal direction loads were applied to each of these designs. The principal stresses (tensile and compressive stress) on each model were calculated using MSC MARC finite element analyze solver software. Results: The tensile stress (P-max) values have been evaluated that they rose at the cervical region of buccal side when the inter-implant distances increased under V and BL loads and they diminished while the inter-implant distances decreased. In short inter-implant distances the compressive stress (P-min) has been presented with increased values and found at the lingual surface of the cervical region. Discussion: The results of this study indicated that the magnitude of the stress was influenced by complex factors such as the direction of loads and the distance between adjacent fixtures. The stress occurring around fixtures differs significantly with various types of inter-implant distance. Conclusion: The evaluation of tensile and compressive stresses for cortical and cancellous bone under V,(MD)-M-1 and BL loading conditions in aspect of inter-implant distance shows; the 1.0 cm of inter-implant distance is the optimum distance for two fixture implantation. (c) 2005 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:199 / 213
页数:15
相关论文
共 50 条
  • [21] The effect of thread design on stress distribution in a solid screw implant: a 3D finite element analysis
    Eraslan, Oguz
    Inan, Oezguer
    CLINICAL ORAL INVESTIGATIONS, 2010, 14 (04) : 411 - 416
  • [22] The effect of thread design on stress distribution in a solid screw implant: a 3D finite element analysis
    Oğuz Eraslan
    Özgür İnan
    Clinical Oral Investigations, 2010, 14 : 411 - 416
  • [23] Stress and strain patterns of 2-implant mandibular overdentures with different positions and angulations of implants: A 3D finite element analysis study
    Patil, Pravinkumar G.
    Seow, Liang Lin
    Uddanwadikar, Rashmi
    Pau, Allan
    Ukey, Piyush D.
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (04): : 586 - 596
  • [24] Stress Distribution on Short Implants at Maxillary Posterior Alveolar Bone Model With Different Bone-to-Implant Contact Ratio: Finite Element Analysis
    Yazicioglu, Duygu
    Bayram, Burak
    Oguz, Yener
    Cinar, Duygu
    Uckan, Sina
    JOURNAL OF ORAL IMPLANTOLOGY, 2016, 42 (01) : 27 - 33
  • [25] Influence of implant design and bone quality on stress/strain distribution in bone around implants: A 3-dimensional finite element analysis
    Tada, S
    Stegaroiu, R
    Kitamura, E
    Miyakawa, O
    Kusakari, H
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2003, 18 (03) : 357 - 368
  • [26] Effect of peri-implantitis associated horizontal bone loss on stress distribution around dental implants - A 3D finite element analysis
    Gupta, Shipra
    Goyal, Parveen
    Jain, Ashish
    Chopra, Priyanka
    MATERIALS TODAY-PROCEEDINGS, 2020, 28 : 1503 - 1509
  • [27] Stress Distribution in Cortical Bone around the Basal Implant - A Finite Element Analysis
    Roy, Anip Kumar
    Dixit, Nivedita
    Punde, Prashant
    Sinha, Koshika Tondon
    Jalaluddin, Mohammad
    Kumar, Ashish
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2021, 13 (05): : 633 - 636
  • [28] Stress Distribution Pattern in Mini Dental Implant-Assisted RPD with Different Clasp Designs: 3D Finite Element Analysis
    Rungsiyakull, Chaiy
    Rungsiyakull, Pimduen
    Suttiat, Kullapop
    Duangrattanaprathip, Nut
    INTERNATIONAL JOURNAL OF DENTISTRY, 2022, 2022
  • [29] Effect of Different Customized Abutment Types on Stress Distribution in Implant-Supported Single Crown: A 3D Finite Element Analysis
    Pumnil, Suphakrit
    Rungsiyakull, Pimduen
    Rungsiyakull, Chaiy
    Elsaka, Shaymaa
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (05): : E2 - E11
  • [30] Comparative Evaluation of the Effect of Implant Crown Materials on Implant Components and Bone Stress Distribution: A 3D Finite Element Analysis
    Nokar, Kimia
    Atri, Faezeh
    Nokar, Saied
    INTERNATIONAL JOURNAL OF DENTISTRY, 2023, 2023