Effects of different inter-implant distances on the stress distribution around endosseous implants in posterior mandible: A 3D finite element analysis

被引:61
|
作者
Simsek, B
Erkmen, E
Yilmaz, D
Eser, A
机构
[1] Gazi Univ, Fac Dent, Dept Oral & Maxillofacial Surg, TR-06690 Ankara, Turkey
[2] Middle E Tech Univ, Dept Mech Engn, Ankara, Turkey
关键词
inter-implant distance; dental implant; peri-implant structure; stress distribution; 3D finite elements analysis;
D O I
10.1016/j.medengphy.2005.04.025
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: The aim of this study was to evaluate the effects of different inter-implant distances on stress distribution in the bone around the endosseous titanium implants under vertical, oblique and horizontal loads in the posterior mandibular edentulousim by finite element analysis (3D FEA). Materials and methods: 3D FEA models representing mandible and ITI (R) implant (Straumann, Waldenburg, Switzerland) were simulated. The distances in-between the units were set at 0.5, 1.0 and 2.0 cm. Vertical (V) 70 degrees N, 60 degrees oblique (BL) 35 degrees N in buccolingual direction and horizontal (MD) 14 degrees N in mesiodistal direction loads were applied to each of these designs. The principal stresses (tensile and compressive stress) on each model were calculated using MSC MARC finite element analyze solver software. Results: The tensile stress (P-max) values have been evaluated that they rose at the cervical region of buccal side when the inter-implant distances increased under V and BL loads and they diminished while the inter-implant distances decreased. In short inter-implant distances the compressive stress (P-min) has been presented with increased values and found at the lingual surface of the cervical region. Discussion: The results of this study indicated that the magnitude of the stress was influenced by complex factors such as the direction of loads and the distance between adjacent fixtures. The stress occurring around fixtures differs significantly with various types of inter-implant distance. Conclusion: The evaluation of tensile and compressive stresses for cortical and cancellous bone under V,(MD)-M-1 and BL loading conditions in aspect of inter-implant distance shows; the 1.0 cm of inter-implant distance is the optimum distance for two fixture implantation. (c) 2005 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:199 / 213
页数:15
相关论文
共 50 条
  • [41] A Nonlinear Three-Dimensional Finite Element Analysis of Stress Distribution and Microstrain Evaluation in Short Dental Implants with Three Different Implant-Abutment Connections in Single and Splinted Conditions in the Posterior Mandible
    Talreja, Karishma S.
    Rodrigues, Shobha J.
    Pai, Umesh Y.
    Shetty, Thilak
    Saldanha, Sharon
    Mahesh, M.
    Hegde, Puneeth
    Shenoy, Satish B.
    Naik, Nithesh
    Mukherjee, Sandipan
    Sales, Ann
    Kamath, Vignesh
    Bajantri, Prashant
    INTERNATIONAL JOURNAL OF DENTISTRY, 2023, 2023
  • [42] Finite element analysis of stress distribution around a dental implant with different amounts of bone loss: An in vitro study
    Jafarian, Mohammad
    Mirhashemi, Fatemeh Sadat
    Emadi, Naghmeh
    DENTAL AND MEDICAL PROBLEMS, 2019, 56 (01) : 27 - 32
  • [43] Comparison of stress distribution in dental crown with different cusp angles: 3D finite element analysis
    Kim, Han-Wool
    Choi, Byung-Ho
    Bae, Eun-Jeong
    Lim, Joong-Yeon
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2019, 22 (03) : 251 - 258
  • [44] Mechanical Influence of Edentulous Mandible Morphology on Peri-implant Bone in Implant Prosthetics: 3D Finite Element Analysis
    Hamada, Takumi
    Gonda, Tomoya
    Murase, Kohei
    Maeda, Yoshinobu
    Ikebe, Kazunori
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2024, 39 (06) : 931 - 937
  • [45] Evaluation of Stress Distribution on Mandibular Implant-Supported Overdentures With Different Bone Heights and Attachment Types: A 3D Finite Element Analysis
    Unsal, Gokce Soganci
    Erbasar, Guzin Neda Hasanoglu
    Aykent, Filiz
    Ozyilmaz, Ozgun Yusuf
    Ozdogan, Mahmut Sertac
    JOURNAL OF ORAL IMPLANTOLOGY, 2019, 45 (05) : 363 - 370
  • [46] Stress Distribution Pattern in Mandibular Overdenture Designs Supported by Three Dental Implants: A 3D Finite Element Analysis
    Aminianpour, Negin
    Alikhasi, Marzieh
    Kasari, Mostafa Shabanpour
    Yousefi, Hashem
    Siadat, Hakimeh
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2025, 11 (01):
  • [47] Effect of surface treatment on stress distribution in immediately loaded dental implants-A 3D finite element analysis
    Bahrami, Babak
    Shahrbaf, Shirin
    Mirzakouchaki, Behnam
    Ghalichi, Farzan
    Ashtiani, Mohammed
    Martin, Nicolas
    DENTAL MATERIALS, 2014, 30 (04) : E89 - E97
  • [48] Stress Distribution in Modified Veneer Crowns: 3D Finite Element Analysis
    Madruga, Camila Ferreira Leite
    Ramos, Gabriela Freitas
    Borges, Alexandre Luiz Souto
    Saavedra, Guilherme de Siqueira Ferreira Anzaloni
    Souza, Rodrigo Othavio
    Marinho, Renata Marques de Melo
    Penteado, Marcela Moreira
    ORAL, 2021, 1 (03): : 272 - 280
  • [49] Splinting Effect on Posterior Implants Under Various Loading Modes: A 3D Finite Element Analysis
    Hauchard, Erwan
    Fournier, Benjamin Philippe
    Jacq, Romain
    Bouton, Antoine
    Pierrisnard, Laurent
    Naveau, Adrien
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2011, 19 (03): : 117 - 122
  • [50] Effect of angled abutments in the posterior maxillary region on tilted implants: a 3D finite element analysis
    Chen, Peng
    Zhang, Jianguo
    Yao, Juan
    Hu, Fengling
    Song, Liang
    Yu, Youcheng
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2024, 62 (08) : 2585 - 2597