Effect of Surgical Guide Design and Surgeon's Experience on the Accuracy of Implant Placement

被引:31
|
作者
Hinckfuss, Simon [2 ]
Conrad, Heather J. [1 ]
Lin, Lianshan [3 ]
Lunos, Scott [4 ]
Seong, Wook-Jin [1 ]
机构
[1] Univ Minnesota, Sch Dent, Dept Restorat Sci, Div Prosthodont, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Sch Dent, Dept Diagnost & Dev Sci, Div Periodont, Minneapolis, MN 55455 USA
[3] Univ Minnesota, Sch Dent, Dept Restorat Sci, MDRCBB, Minneapolis, MN 55455 USA
[4] Univ Minnesota, Biostat Design & Anal Ctr, Clin & Translat Sci Inst, Minneapolis, MN USA
关键词
surgical guide; implant placement; COMPUTED-TOMOGRAPHY; ANTERIOR MAXILLA; DENTAL IMPLANTS; IN-VITRO; FABRICATION; RESTORATIONS; RELIABILITY; AESTHETICS;
D O I
10.1563/AAID-JOI-D-10-00046
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Implant position is a key determinant of esthetic and functional success. Achieving the goal of ideal implant position may be affected by case selection, prosthodontically driven treatment planning, site preparation, surgeon's experience and use of a surgical guide. The combined effect of surgical guide design, surgeon's experience, and size of the edentulous area on the accuracy of implant placement was evaluated in a simulated clinical setting. Twenty-one volunteers were recruited to participate in the study. They were divided evenly into 3 groups (novice, intermediate, and experienced). Each surgeon placed implants in single and double sites using 4 different surgical guide designs (no guide, tube, channel, and guided) and written instructions describing the ideal implant positions. A definitive typodont was constructed that had 3 implants in prosthetically determined ideal positions of single and double sites. The position and angulation of implants placed by the surgeons in the duplicate typodonts was measured using a computerized coordinate measuring machine and compared to the definitive typodont. The mean absolute positional error for all guides was 0.273, 0.340, 0.197 mm in mesial-distal, buccal-lingual, vertical positions, respectively, with an overall range of 0.00 to 1.81 mm. The mean absolute angle error for all guides was 1.61 degrees and 2.39 degrees in the mesial-distal and buccal-lingual angulations, respectively, with an overall range of 0.01 degrees to 9.7 degrees. Surgical guide design had a statistically significant effect on the accuracy of implant placement regardless of the surgeon's experience level. Experienced surgeons had significantly less error in buccal-lingual angulation. The size of the edentulous sites was found to affect both implant angle and position significantly. The magnitude of error in position and angulation caused by surgical guide design, surgeon's experience, and site size reported in this study are possibly not large enough to be clinically significant; however, it is likely that errors would be magnified in clinical practice. Future research is recommended to evaluate the effect of surgical guide design in vivo on implant angulation and position error.
引用
收藏
页码:311 / 324
页数:14
相关论文
共 50 条
  • [1] Accuracy of implant placement with a stereolithographic surgical guide
    Sarment, DP
    Sukovic, P
    Clinthorne, N
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2003, 18 (04) : 571 - 577
  • [2] An In Vitro Model to Evaluate the Accuracy of Guided Implant Placement Based on the Surgeon's Experience
    Fernandez-Gil, Angeles
    Serrano Gil, Herminia
    Gonzalez Velasco, Miguel
    Moreno Vazquez, Jose C.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (03) : 515 - 524
  • [3] Influence of Surgeon Experience on the Accuracy of Implant Placement via a Partially Computer-Guided Surgical Protocol
    Marei, Hesham F.
    Abdel-Hady, Adel
    Al-Khalifa, Khalifa
    Al-Mahalawy, Haytham
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (05) : 1173 - 1179
  • [4] A SURGICAL GUIDE FOR IMPLANT PLACEMENT
    RENDER, PJ
    FONDAK, JT
    JOURNAL OF PROSTHETIC DENTISTRY, 1992, 67 (06): : 831 - 832
  • [5] Accuracy of miniscrew implant placement with a 3-dimensional surgical guide
    Suzuki, Eduardo Yugo
    Suzuki, Boonsiva
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2008, 66 (06) : 1245 - 1252
  • [6] THE ACCURACY OF IMPLANT PLACEMENT WITH SURGICAL GUIDE STENT IN THE KINGDOM OF SAUDI ARABIA
    Almahroos, Hassan A.
    Al Hazeem, Adel A.
    Alzahrani, Khames T.
    Alzain, Jinan A.
    Ahmed, Ragad S.
    Alsharif, Arwa H.
    Albaiti, Badoor M.
    ANNALS OF DENTAL SPECIALTY, 2020, 8 (04): : 44 - 46
  • [7] Surgical guide for dental implant placement
    Becker, CM
    Kaiser, DA
    JOURNAL OF PROSTHETIC DENTISTRY, 2000, 83 (02): : 248 - 251
  • [8] Flexible surgical guide to improve implant placement accuracy. Dental technique
    El-Danasory, Muhammed B.
    Kamar, AbdelKarim M.
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2023, 124 (02)
  • [9] Use of transitional implants to support a surgical guide: Enhancing the accuracy of implant placement
    Simon, H
    JOURNAL OF PROSTHETIC DENTISTRY, 2002, 87 (02): : 229 - 232
  • [10] Accuracy of dynamic navigation compared to static surgical guide for dental implant placement
    Wu, Dong
    Zhou, Lin
    Yang, Jin
    Zhang, Bao
    Lin, Yanjun
    Chen, Jiang
    Huang, Wenxiu
    Chen, Yonghui
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)