Accuracy of implant placement with a stereolithographic surgical guide

被引:0
|
作者
Sarment, DP
Sukovic, P
Clinthorne, N
机构
[1] Univ Michigan, Sch Dent, Dept Periodont Prevent Geriatr, Ann Arbor, MI 48109 USA
[2] Xoran Technol, Ann Arbor, MI USA
[3] Univ Michigan, Dept Radiol, Ann Arbor, MI 48109 USA
关键词
computed tomography; computer-aided design; dental implants; stereolithography; surgical templates;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Placement of dental implants requires precise planning that accounts for anatomic limitations and restorative goals. Diagnosis can be made with the assistance of computerized tomographic (CT) scanning, but transfer of planning to the surgical field is limited. Recently, novel CAD/CAM techniques such as stereolithographic rapid prototyping have been developed to build surgical guides in an attempt to improve precision of implant placement. However, comparison of these advanced techniques to traditional surgical guides has not been performed. The goal of this study was to compare the accuracy of a conventional surgical guide to that of a stereolithographic surgical guide. Materials and Methods: CT scanning of epoxy edentulous mandibles was performed using a cone beam CT scanner with high isotropic spatial resolution, while planning for 5 implants on each side of the jaw was performed using a commercially available software package. Five surgeons performed osteotomies on a jaw identical to the initial model; on the right side a conventional surgical guide (control side) was used, and on the left side a stereolithographic guide was used (test side). Each jaw was then CT scanned, and a registration method was applied to match it to the initial planning. Measurements included distances between planned implants and actual osteotomies. Results: The average distance between the planned implant and the actual osteotomy was 1.5 mm at the entrance and 2.1 mm at the apex when the control guide was used. The same measurements were significantly reduced to 0.9 mm and 1.0 mm when the test guide was used. Variations were also reduced with the test guide, within surgeons and between surgeons. Discussion: Surgical guidance for implant placement relieves the clinician from multiple perioperative decisions. Precise implant placement is under investigation using sophisticated guidance methods, including CAD/CAM templates. Conclusion: Within the limits of this study, implant placement was improved by using a stereolithographic surgical guide.
引用
收藏
页码:571 / 577
页数:7
相关论文
共 50 条
  • [1] Accuracy of Implant Placement with a Stereolithographic Surgical Template
    Cassetta, Michele
    Stefanelli, Luigi V.
    Giansanti, Matteo
    Calasso, Sabrina
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (03) : 655 - 663
  • [2] Implant Placement Accuracy When Using Stereolithographic Template as a Surgical Guide: Preliminary Results
    Al-Harbi, Saad A.
    Sun, Albert Y. T.
    [J]. IMPLANT DENTISTRY, 2009, 18 (01) : 46 - 51
  • [3] ACCURACY OF THREE DIFFERENT TYPES OF STEREOLITHOGRAPHIC SURGICAL GUIDE IN IMPLANT PLACEMENT: AN IN VITRO STUDY
    Turbush, Sarah Katherine
    Turkyilmaz, Ilser
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2012, 108 (03): : 181 - 188
  • [4] Application and Success of Two Stereolithographic Surgical Guide Systems for Implant Placement with Immediate Loading
    Abboud, Marcus
    Wahl, Gerhard
    Calvo Guirado, Jose Luis
    Orentlicher, Gary
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (03) : 634 - 643
  • [5] IMPACT OF OPERATOR EXPERIENCE ON THE ACCURACY OF IMPLANT PLACEMENT WITH STEREOLITHOGRAPHIC SURGICAL TEMPLATES: AN IN VITRO STUDY
    Cushen, Sarra E.
    Turkyilmaz, Ilser
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2013, 109 (04): : 248 - 254
  • [6] Effect of Smoking Habits on Accuracy of Implant Placement Using Mucosally Supported Stereolithographic Surgical Guides
    D'haese, Jan
    De Bruyn, Hugo
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (03) : 402 - 411
  • [7] A SURGICAL GUIDE FOR IMPLANT PLACEMENT
    RENDER, PJ
    FONDAK, JT
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1992, 67 (06): : 831 - 832
  • [8] Accuracy of miniscrew implant placement with a 3-dimensional surgical guide
    Suzuki, Eduardo Yugo
    Suzuki, Boonsiva
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2008, 66 (06) : 1245 - 1252
  • [9] THE ACCURACY OF IMPLANT PLACEMENT WITH SURGICAL GUIDE STENT IN THE KINGDOM OF SAUDI ARABIA
    Almahroos, Hassan A.
    Al Hazeem, Adel A.
    Alzahrani, Khames T.
    Alzain, Jinan A.
    Ahmed, Ragad S.
    Alsharif, Arwa H.
    Albaiti, Badoor M.
    [J]. ANNALS OF DENTAL SPECIALTY, 2020, 8 (04): : 44 - 46
  • [10] Factors affecting accuracy of implant placement with mucosa-supported stereolithographic surgical guides in edentulous mandibles
    Ochi, Megumi
    Kanazawa, Manabu
    Sato, Daisuke
    Kasugai, Shohei
    Hirano, Shigezo
    Minakuchi, Shunsuke
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (11) : 1653 - 1660