Effect of Surgical Guide Design and Surgeon's Experience on the Accuracy of Implant Placement

被引:31
|
作者
Hinckfuss, Simon [2 ]
Conrad, Heather J. [1 ]
Lin, Lianshan [3 ]
Lunos, Scott [4 ]
Seong, Wook-Jin [1 ]
机构
[1] Univ Minnesota, Sch Dent, Dept Restorat Sci, Div Prosthodont, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Sch Dent, Dept Diagnost & Dev Sci, Div Periodont, Minneapolis, MN 55455 USA
[3] Univ Minnesota, Sch Dent, Dept Restorat Sci, MDRCBB, Minneapolis, MN 55455 USA
[4] Univ Minnesota, Biostat Design & Anal Ctr, Clin & Translat Sci Inst, Minneapolis, MN USA
关键词
surgical guide; implant placement; COMPUTED-TOMOGRAPHY; ANTERIOR MAXILLA; DENTAL IMPLANTS; IN-VITRO; FABRICATION; RESTORATIONS; RELIABILITY; AESTHETICS;
D O I
10.1563/AAID-JOI-D-10-00046
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Implant position is a key determinant of esthetic and functional success. Achieving the goal of ideal implant position may be affected by case selection, prosthodontically driven treatment planning, site preparation, surgeon's experience and use of a surgical guide. The combined effect of surgical guide design, surgeon's experience, and size of the edentulous area on the accuracy of implant placement was evaluated in a simulated clinical setting. Twenty-one volunteers were recruited to participate in the study. They were divided evenly into 3 groups (novice, intermediate, and experienced). Each surgeon placed implants in single and double sites using 4 different surgical guide designs (no guide, tube, channel, and guided) and written instructions describing the ideal implant positions. A definitive typodont was constructed that had 3 implants in prosthetically determined ideal positions of single and double sites. The position and angulation of implants placed by the surgeons in the duplicate typodonts was measured using a computerized coordinate measuring machine and compared to the definitive typodont. The mean absolute positional error for all guides was 0.273, 0.340, 0.197 mm in mesial-distal, buccal-lingual, vertical positions, respectively, with an overall range of 0.00 to 1.81 mm. The mean absolute angle error for all guides was 1.61 degrees and 2.39 degrees in the mesial-distal and buccal-lingual angulations, respectively, with an overall range of 0.01 degrees to 9.7 degrees. Surgical guide design had a statistically significant effect on the accuracy of implant placement regardless of the surgeon's experience level. Experienced surgeons had significantly less error in buccal-lingual angulation. The size of the edentulous sites was found to affect both implant angle and position significantly. The magnitude of error in position and angulation caused by surgical guide design, surgeon's experience, and site size reported in this study are possibly not large enough to be clinically significant; however, it is likely that errors would be magnified in clinical practice. Future research is recommended to evaluate the effect of surgical guide design in vivo on implant angulation and position error.
引用
收藏
页码:311 / 324
页数:14
相关论文
共 50 条
  • [31] Accuracy of a milled digital implant surgical guide: An in vitro study
    Liu, Xiaoqian
    Liu, Jianzhang
    Feng, Hailan
    Pan, Shaoxia
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (03): : 453 - 461
  • [32] Effect of the Configurations of Fiducial Markers on the Accuracy of Surgical Navigation in Zygomatic Implant Placement: An In Vitro Study
    Fan, Shengchi
    Hung, Kuofeng
    Bornstein, Michael M.
    Huang, Wei
    Wang, Feng
    Wu, Yiqun
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (01) : 85 - 90
  • [33] Effect of Smoking Habits on Accuracy of Implant Placement Using Mucosally Supported Stereolithographic Surgical Guides
    D'haese, Jan
    De Bruyn, Hugo
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (03) : 402 - 411
  • [34] Effect of pilot-guided implant placement concept on the accuracy of osteotomy preparation and implant placement
    Sharma, Shruti
    Tan, Emilie
    Tran, Britney
    Siow, Hui Y.
    Tafesse, Elshadaie
    Thong, Yoong H. J.
    Tan, Row J. M.
    Son, Jungwoo
    Todaro, Lisa
    Teo, Josephine
    Abduo, Jaafar
    JOURNAL OF ORAL SCIENCE, 2024, 66 (01) : 20 - 25
  • [35] Implant success positively correlated with surgeon's experience
    Kokich, V
    ANGLE ORTHODONTIST, 1998, 68 (02) : 105 - 105
  • [36] Is a digital surgical guide superior for implant placement in the first molars areas?
    Mourao, Carlos Fernando de Almeida Barros
    Machado, Aldir N.
    Casado, Priscila
    EVIDENCE-BASED DENTISTRY, 2022, 23 (02) : 58 - 59
  • [37] LINE-OF-VISION SURGICAL GUIDE TO IMPLANT PLACEMENT IN THE ANTERIOR MANDIBLE
    MCCARTNEY, JW
    JOURNAL OF PROSTHETIC DENTISTRY, 1993, 70 (06): : 551 - 552
  • [38] The accuracy of a partially guided system using an in-office 3D-printed surgical guide for implant placement
    Cho, Jin-yong
    Kim, Sung-beom
    Ryu, Jaeyoung
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2021, 24 (01) : 19 - 27
  • [39] Accuracy of Implant Placement Guided with Surgical Template: An In Vitro and In Vivo Study
    Zhou, Miao
    Zhou, Hui
    Li, Shu-Yi
    Yang, Xiao-Bin
    Geng, Yuan-Ming
    Che, Yue-Juan
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2021, 41 (02) : E55 - E62
  • [40] Considerations in Dental Implant Placement in the Young Patient: A Surgeon's Perspective
    Holmes, Jon D.
    SEMINARS IN ORTHODONTICS, 2013, 19 (01) : 24 - 36