Effect of Surgical Guide Design and Surgeon's Experience on the Accuracy of Implant Placement

被引:31
|
作者
Hinckfuss, Simon [2 ]
Conrad, Heather J. [1 ]
Lin, Lianshan [3 ]
Lunos, Scott [4 ]
Seong, Wook-Jin [1 ]
机构
[1] Univ Minnesota, Sch Dent, Dept Restorat Sci, Div Prosthodont, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Sch Dent, Dept Diagnost & Dev Sci, Div Periodont, Minneapolis, MN 55455 USA
[3] Univ Minnesota, Sch Dent, Dept Restorat Sci, MDRCBB, Minneapolis, MN 55455 USA
[4] Univ Minnesota, Biostat Design & Anal Ctr, Clin & Translat Sci Inst, Minneapolis, MN USA
关键词
surgical guide; implant placement; COMPUTED-TOMOGRAPHY; ANTERIOR MAXILLA; DENTAL IMPLANTS; IN-VITRO; FABRICATION; RESTORATIONS; RELIABILITY; AESTHETICS;
D O I
10.1563/AAID-JOI-D-10-00046
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Implant position is a key determinant of esthetic and functional success. Achieving the goal of ideal implant position may be affected by case selection, prosthodontically driven treatment planning, site preparation, surgeon's experience and use of a surgical guide. The combined effect of surgical guide design, surgeon's experience, and size of the edentulous area on the accuracy of implant placement was evaluated in a simulated clinical setting. Twenty-one volunteers were recruited to participate in the study. They were divided evenly into 3 groups (novice, intermediate, and experienced). Each surgeon placed implants in single and double sites using 4 different surgical guide designs (no guide, tube, channel, and guided) and written instructions describing the ideal implant positions. A definitive typodont was constructed that had 3 implants in prosthetically determined ideal positions of single and double sites. The position and angulation of implants placed by the surgeons in the duplicate typodonts was measured using a computerized coordinate measuring machine and compared to the definitive typodont. The mean absolute positional error for all guides was 0.273, 0.340, 0.197 mm in mesial-distal, buccal-lingual, vertical positions, respectively, with an overall range of 0.00 to 1.81 mm. The mean absolute angle error for all guides was 1.61 degrees and 2.39 degrees in the mesial-distal and buccal-lingual angulations, respectively, with an overall range of 0.01 degrees to 9.7 degrees. Surgical guide design had a statistically significant effect on the accuracy of implant placement regardless of the surgeon's experience level. Experienced surgeons had significantly less error in buccal-lingual angulation. The size of the edentulous sites was found to affect both implant angle and position significantly. The magnitude of error in position and angulation caused by surgical guide design, surgeon's experience, and site size reported in this study are possibly not large enough to be clinically significant; however, it is likely that errors would be magnified in clinical practice. Future research is recommended to evaluate the effect of surgical guide design in vivo on implant angulation and position error.
引用
收藏
页码:311 / 324
页数:14
相关论文
共 50 条
  • [21] A SURGICAL GUIDE FOR DENTAL IMPLANT PLACEMENT IN AN EDENTULOUS JAW
    Wat, Peter Y. P.
    Pow, Edmond H. N.
    Chau, Francis S. W.
    Leung, Iatherine C. M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2008, 100 (04): : 323 - 325
  • [22] Implant placement with surgical (guide) templates (coDiagnostiX (R))
    Nickenig, H. J.
    MKG-CHIRURG, 2008, 1 (01): : 43 - 48
  • [23] A SURGICAL GUIDE FOR CRANIOFACIAL IMPLANT PLACEMENT FOR AN IMPLANT-RETAINED AURICULAR PROSTHESIS
    Ozcelik, Tuncer Burak
    Tanner, Paul Benjamin
    JOURNAL OF PROSTHETIC DENTISTRY, 2010, 103 (04): : 253 - 255
  • [24] Development and clinical application of a surgical guide for optimal implant placement
    Koyanagi, K
    JOURNAL OF PROSTHETIC DENTISTRY, 2002, 88 (05): : 548 - 552
  • [25] Free-Hand versus Surgical Guide Implant Placement
    Afshari, Aysooda
    Shahmohammadi, Rojin
    Mosaddad, Seyed Ali
    Pesteei, Ozra
    Hajmohammadi, Emran
    Rahbar, Mahdi
    Alam, Mostafa
    Abbasi, Kamyar
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2022, 2022
  • [26] A surgical guide for dental implant placement in edentulous posterior regions
    Atsu, Saadet Saglam
    JOURNAL OF PROSTHETIC DENTISTRY, 2006, 96 (02): : 129 - 133
  • [27] Surgical oral radiographic guide with a removable component for implant placement
    Shahrasbi, AH
    Hansen, CA
    JOURNAL OF PROSTHETIC DENTISTRY, 2002, 87 (03): : 330 - 332
  • [28] Orthopedic Implant Design from Concept to Final Tested Product : A Design Surgeon's Experience
    Pretorius, Henry Sean
    Ferreira, Nando
    JOURNAL OF LIMB LENGTHENING & RECONSTRUCTION, 2021, 7 (01) : 45 - 51
  • [29] Accuracy of Implant Placement with a Navigation System, a Laboratory Guide, and Freehand Drilling
    Chen, Chang-Kai
    Yuh, Da-Yo
    Huang, Ren-Yeong
    Fu, Earl
    Tsai, Cheng-Feng
    Chiang, Cheng-Yang
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (06) : 1213 - 1218
  • [30] Effect of the use of a surgical guide on heat generation during implant placement: A comparative in vitro study
    Alhroob, Khaldoun Hossein
    Alsabbagh, Mohammed Monzer
    Alsabbagh, Aghiad Yassin
    DENTAL AND MEDICAL PROBLEMS, 2021, 58 (01) : 55 - 59