Impaction allografting with cement for revision of the femoral component - A minimum four-year follow-up study with use of a precoated femoral stem

被引:80
|
作者
Leopold, SS [1 ]
Berger, RA [1 ]
Rosenberg, AG [1 ]
Jacobs, JJ [1 ]
Quigley, LR [1 ]
Galante, JO [1 ]
机构
[1] Rush Presbyterian St Lukes Med Ctr, Dept Orthopaed Surg, Chicago, IL 60612 USA
来源
关键词
D O I
10.2106/00004623-199908000-00004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Cancellous impaction allografting with cement for revision of the femoral component has conventionally been performed with a polished, tapered implant, which was designed to allow subsidence of the component. However, subsidence has been associated with pain in the thigh, dislocation of the hip, and revision of the component, This prospective study tested the hypothesis that good clinical results can be achieved - without subsidence of the component - with use of impaction allografting and a precoated, collared, straight stem for difficult femoral revisions. Methods: Twenty-nine patients had revision of the femoral component with use of impaction allografting with cement and a Harris Precoat stem. Impaction allografting was performed when loss of metaphyseal and diaphyseal bone precluded revision with more straightforward techniques or when reconstitution of bone was considered a specific goal of the reconstruction (as was sometimes the case with revision of the component in younger patients), The patients were followed prospectively and were evaluated with use of the Harris hip score and serial radiographs. The patients were followed for a minimum of four years (mean, sixty-three mouths), except for four who died. Results: Four patients died before the minimum four-year follow-np period had elapsed; all four had the prosthesis in place at the time of death. The Harris hip scores improved from a preoperative mean of 54 points (poor) (range, 21 to 91 points) to a mean of 87 points (good) (range, 41 to 100 paints) at the time of the most recent follow-up. Kaplan-Meier survivorship analysis, with aseptic loosening as the end point, was 92 percent (95 percent confidence interval, 82 to 100 percent) at six years; one additional hip failed because of a hematogenous infection at seventy-three months postoperatively, for an overall failure rate of 12 percent (three of twenty-five patients) at the time of the most recent follow-up, Two hips needed a repeat revision; one was revised because of subsidence of the stem with recurrent osteolysis and the other, in a patient who had hemodialysis, because of late sepsis.. A third femoral component subsided and failed but was not revised. Radiographic evidence of bone-stock reconstitution was observed in six (29 percent) of the twenty-one patients for whom radiographs were available; As in other series of patients managed with impaction allografting, the complication rate was high; excluding the revisions, three reoperations were performed, and six patients had either intraoperative femoral fracture or perforation necessitating cerclage wiring or cortical strut allografting: and cerclage wiring at the time of the procedure, There were six nonunions in eighteen patients who had been operated on with a transtrochanteric approach. Conclusions Difficult revisions of the femoral component with use of impaction allografting and a precoated stem provided satisfactory clinical and radiographic results at the time of intermediate-term follow-up. However, the high rate of complications in our series led us to refine our indications for the procedure.
引用
收藏
页码:1080 / 1092
页数:13
相关论文
共 50 条
  • [31] Slowly progressive aphasia: a four-year follow-up study
    Papagno, C
    Capitani, E
    NEUROPSYCHOLOGIA, 2001, 39 (07) : 678 - 686
  • [32] Staged Revision Hip Arthroplasty With Femoral Impaction Bone Grafting for Prosthetic Joint Infections: Radiostereometric Analyses and Clinical Outcomes at Minimum 5-Year Follow-Up
    Bunting, Alexandra C.
    Costi, Kerry
    Chimutengwende-Gordon, Mukai
    Callary, Stuart A.
    Pannach, Susan
    Nelson, Renjy
    Howie, Donald W.
    Solomon, Lucian Bogdan
    JOURNAL OF ARTHROPLASTY, 2023, 38 (12): : 2716 - 2723.e1
  • [33] 5- to 13-year follow-up study on cementless femoral components in revision surgery
    Krishnamurthy, AB
    MacDonald, SJ
    Paprosky, WG
    JOURNAL OF ARTHROPLASTY, 1997, 12 (08): : 839 - 847
  • [34] Clinical and radiographic analysis of the Mallory-Head femoral component in revision total hip arthroplasty - A minimum 8.8-year and average eleven-year follow-up study
    Emerson, RH
    Head, WC
    Higgins, LL
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (10): : 1921 - 1926
  • [35] Use of a Modular Tapered Fluted Femoral Component in Revision Total Hip Arthroplasty Following Resection of a Previously Infected Total Hip: Minimum 5-year Follow-Up
    Houdek, Matthew T.
    Perry, Kevin I.
    Wyles, Cody C.
    Berry, Daniel J.
    Sierra, Rafael J.
    Trousdale, Robert T.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (03): : 435 - 438
  • [36] Integral porous femoral stem - 5- to 8-year follow-up study
    Mauerhan, DR
    Mesa, J
    Gregory, AM
    Mokris, JG
    JOURNAL OF ARTHROPLASTY, 1997, 12 (03): : 250 - 255
  • [37] Clinical outcomes and survival rate of cementless modular distal fixation femoral stem for revision hip arthroplasty: A minimum 6-year follow-up
    Kang, Joon Soon
    Na, Yeop
    Ko, Bong Seong
    Jeon, Yoon Sang
    JOURNAL OF ORTHOPAEDIC SURGERY, 2018, 26 (03):
  • [38] Total hip arthroplasty with a cemented, polished, collared femoral stem and a cementless acetabular component - A follow-up study at a minimum of ten years
    Firestone, Daniel E.
    Callaghan, John J.
    Liu, Steve S.
    Goetz, Devon D.
    Sullivan, Patrick M.
    Vittetoe, David A.
    Johnston, Richard C.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (01): : 126 - 132
  • [39] Total Hip Arthroplasty Using Cementless Grit-Blasted Femoral Component A Minimum 10-Year Follow-Up Study
    Hwang, Kyu-Tae
    Kim, Young-Ho
    Kim, Yee-Suk
    Choi, Il-Yong
    JOURNAL OF ARTHROPLASTY, 2012, 27 (08): : 1554 - 1561
  • [40] Primary cementless total hip arthroplasty using a modular femoral component - A minimum 6-year follow-up
    Tanzer, M
    Chan, S
    Brooks, CE
    Bobyn, JD
    JOURNAL OF ARTHROPLASTY, 2001, 16 (08): : 64 - 70