Primary cementless total hip arthroplasty using a modular femoral component - A minimum 6-year follow-up

被引:34
|
作者
Tanzer, M [1 ]
Chan, S [1 ]
Brooks, CE [1 ]
Bobyn, JD [1 ]
机构
[1] McGill Univ, Div Orthopaed Surg, Montreal, PQ, Canada
来源
JOURNAL OF ARTHROPLASTY | 2001年 / 16卷 / 08期
关键词
hip; arthroplasty; modular; S-ROM; femoral prosthesis;
D O I
10.1054/arth.2001.29140
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We evaluated 59 hips that underwent a primary total hip arthroplasty using an S-ROM modular femoral component at a mean follow-up of 101 months (range, 72-145 months). All cases showed radiographic evidence of bone ingrowth, and there were no femoral revisions for aseptic loosening. The Harris hip score improved from a mean of 40 preoperatively to 89 at final follow-up. Some degree of proximal femoral disuse atrophy from stress shielding occurred in 46 hips (78%), and some degree of femoral osteolysis occurred in 25 hips (42%). Only additional follow-up will reveal whether there is a consequence of both types of proximal femoral bone loss.
引用
收藏
页码:64 / 70
页数:7
相关论文
共 50 条
  • [1] Clinical outcomes and survival rate of cementless modular distal fixation femoral stem for revision hip arthroplasty: A minimum 6-year follow-up
    Kang, Joon Soon
    Na, Yeop
    Ko, Bong Seong
    Jeon, Yoon Sang
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY, 2018, 26 (03):
  • [2] Total Hip Arthroplasty Using Cementless Grit-Blasted Femoral Component A Minimum 10-Year Follow-Up Study
    Hwang, Kyu-Tae
    Kim, Young-Ho
    Kim, Yee-Suk
    Choi, Il-Yong
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (08): : 1554 - 1561
  • [3] The Synergy cementless femoral stem in primary total hip arthroplasty at a minimum follow-up of 15 years
    De Martino, I.
    De Santis, V.
    D'Apolito, R.
    Sculco, P. K.
    Cross, M. B.
    Gasparini, G.
    [J]. BONE & JOINT JOURNAL, 2017, 99B (01): : 29 - 36
  • [4] High Failure at a Minimum 5-Year Follow-Up in Primary Total Hip Arthroplasty Using a Modular Femoral Trunnion
    Nahhas, Cindy R.
    Yi, Paul H.
    Moric, Mario
    Puri, Rajeev
    Jacobs, Joshua J.
    Sporer, Scott M.
    [J]. JOURNAL OF ARTHROPLASTY, 2019, 34 (07): : 1395 - 1399
  • [5] SURVIVORSHIP ANALYSIS OF MODULAR FEMORAL STEMS IN TOTAL HIP ARTHROPLASTY, MINIMUM 10 YEAR FOLLOW-UP
    Mehic, E.
    Scott, D.
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 2017, 65 (01) : 219 - 219
  • [6] Comparison Between Preassembled and Modular Cups in Primary Cementless Total Hip Arthroplasty: A Two-Year Minimum Follow-up Study
    Shin, Young-Soo
    Han, Seung-Beom
    Jung, Tae-Wan
    [J]. JOURNAL OF ARTHROPLASTY, 2014, 29 (12): : 2378 - 2382
  • [7] Cementless Modular Total Hip Arthroplasty in Patients Younger than Fifty with Femoral Head Osteonecrosis: Minimum Fifteen-Year Follow-Up
    Kim, Sang-Min
    Lim, Seung-Jae
    Moon, Young-Wan
    Kim, Yang-Tae
    Ko, Kyung-Rae
    Park, Youn-Soo
    [J]. JOURNAL OF ARTHROPLASTY, 2013, 28 (03): : 504 - 509
  • [8] Long-Term Survivorship of Modular Cementless Femoral Stem in Complex Primary Total Hip Arthroplasty: A Concise Minimum 15-Year Follow-Up Report
    Bawale, Rajesh
    Matar, Hosam E.
    Illanes, Felipe Lopez
    Cameron, Hugh U.
    [J]. JOURNAL OF ARTHROPLASTY, 2021, 36 (09): : 3221 - 3225
  • [9] Comparison of modular and nonmodular tapered fluted titanium stems in femoral revision hip arthroplasty: a minimum 6-year follow-up study
    Shuo Feng
    Yu Zhang
    Yu-Hang Bao
    Zhi Yang
    Guo-Chun Zha
    Xiang-Yang Chen
    [J]. Scientific Reports, 10
  • [10] Comparison of modular and nonmodular tapered fluted titanium stems in femoral revision hip arthroplasty: a minimum 6-year follow-up study
    Feng, Shuo
    Zhang, Yu
    Bao, Yu-Hang
    Yang, Zhi
    Zha, Guo-Chun
    Chen, Xiang-Yang
    [J]. SCIENTIFIC REPORTS, 2020, 10 (01)