Primary cementless total hip arthroplasty using a modular femoral component - A minimum 6-year follow-up

被引:34
|
作者
Tanzer, M [1 ]
Chan, S [1 ]
Brooks, CE [1 ]
Bobyn, JD [1 ]
机构
[1] McGill Univ, Div Orthopaed Surg, Montreal, PQ, Canada
来源
JOURNAL OF ARTHROPLASTY | 2001年 / 16卷 / 08期
关键词
hip; arthroplasty; modular; S-ROM; femoral prosthesis;
D O I
10.1054/arth.2001.29140
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We evaluated 59 hips that underwent a primary total hip arthroplasty using an S-ROM modular femoral component at a mean follow-up of 101 months (range, 72-145 months). All cases showed radiographic evidence of bone ingrowth, and there were no femoral revisions for aseptic loosening. The Harris hip score improved from a mean of 40 preoperatively to 89 at final follow-up. Some degree of proximal femoral disuse atrophy from stress shielding occurred in 46 hips (78%), and some degree of femoral osteolysis occurred in 25 hips (42%). Only additional follow-up will reveal whether there is a consequence of both types of proximal femoral bone loss.
引用
收藏
页码:64 / 70
页数:7
相关论文
共 50 条
  • [31] Three to seven year follow-up of a tapered modular femoral prosthesis in revision total hip arthroplasty
    Wang, Long
    Dai, Zixun
    Wen, Ting
    Li, Mingqing
    Hu, Yihe
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (02) : 275 - 281
  • [32] Revision Total Hip Arthroplasty Using a Cementless Cup Supporter and Iliac Autograft: A Minimum of 15-Year Follow-Up
    Yoshino, Kensuke
    Tsukeoka, Tadashi
    Tsuneizumi, Yoshikazu
    Lee, Tae Hyun
    Nakamura, Junichi
    Suzuki, Masahiko
    Ohtori, Seiji
    [J]. JOURNAL OF ARTHROPLASTY, 2017, 32 (11): : 3495 - 3501
  • [33] Minimum 6-Year Follow-Up of Revision Total Knee Arthroplasty Without Patella Reimplantation
    Dalury, David F.
    Adams, Mary Jo
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (08): : 91 - 94
  • [34] Straight Tapered Titanium Stem With Alumina Bearing in Cementless Primary Total Hip Arthroplasty A Minimum 5-Year Follow-Up
    Hwang, Bo-Hyun
    Lee, Woo-Suk
    Park, Kwan-Kyu
    Yang, Ick-Hwan
    Han, Chang-Dong
    [J]. JOURNAL OF ARTHROPLASTY, 2011, 26 (08): : 1310 - 1317
  • [35] OBLIQUE FEMORAL OSTEOTOMY IN CEMENTLESS TOTAL HIP-ARTHROPLASTY - PROSPECTIVE CONSECUTIVE SERIES WITH A 3-YEAR MINIMUM FOLLOW-UP PERIOD
    HUO, MH
    ZATORSKI, LE
    KEGGI, KJ
    [J]. JOURNAL OF ARTHROPLASTY, 1995, 10 (03): : 319 - 327
  • [36] Total Knee Arthroplasty Using Cementless Porous Tantalum Monoblock Tibial Component: A Minimum 10-Year Follow-Up
    De Martino, Ivan
    D'Apolito, Rocco
    Sculco, Peter K.
    Poultsides, Lazaros A.
    Gasparini, Giorgio
    [J]. JOURNAL OF ARTHROPLASTY, 2016, 31 (10): : 2193 - 2198
  • [37] Cementless acetabular cup: 6-year follow-up
    Giménez A.
    Llinares T.
    Gil A.
    [J]. Journal of Orthopaedics and Traumatology, 2002, 3 (2) : 85 - 87
  • [38] REVISION OF THE ACETABULAR COMPONENT WITHOUT CEMENT AFTER TOTAL HIP-ARTHROPLASTY - 3-YEAR TO 6-YEAR FOLLOW-UP
    PADGETT, DE
    KULL, L
    ROSENBERG, A
    SUMNER, DR
    GALANTE, JO
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (05): : 663 - 673
  • [39] Total hip arthroplasty with an uncemented femoral component - Excellent results at ten-year follow-up
    McLaughlin, JR
    Lee, KR
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (06): : 900 - 907
  • [40] Total hip arthroplasty using an uncemented femoral component with taper design: outcome at 10-year follow-up
    Schramm, M
    Hohmann, D
    Pitto, RP
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2000, 120 (7-8) : 407 - 412