A fast method for rescaling voxel S values for arbitrary voxel sizes in targeted radionuclide therapy from a single Monte Carlo calculation

被引:12
|
作者
Fernandez, Maria [1 ]
Haenscheid, Heribert [1 ]
Mauxion, Thibault [2 ]
Bardies, Manuel [2 ]
Kletting, Peter [3 ]
Glatting, Gerhard [4 ]
Lassmann, Michael [1 ]
机构
[1] Univ Wurzburg, Dept Nucl Med, D-97080 Wurzburg, Germany
[2] Ctr Rech Cancerol Toulouse, UPS, INSERM, UMR 1037, F-31062 Toulouse, France
[3] Univ Ulm, Dept Nucl Med, D-89081 Ulm, Germany
[4] Heidelberg Univ, Med Fac Mannheim, D-68167 Mannheim, Germany
关键词
Voxel S values (VSVs); Monte-Carlo simulation; targeted radionuclide therapy (TRT); internal dosimetry; NONUNIFORM ACTIVITY DISTRIBUTIONS; DOSE CALCULATIONS; DOSIMETRY; ENERGIES; PHANTOMS; ADULT; CODES;
D O I
10.1118/1.4812684
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In targeted radionuclide therapy, patient-specific dosimetry based on voxel S values (VSVs) is preferable to dosimetry based on mathematical phantoms. Monte-Carlo (MC) simulations are necessary to deduce VSVs for those voxel sizes required by quantitative imaging. The aim of this study is, starting from a single set of high-resolution VSVs obtained by MC simulations for a small voxel size along one single axis perpendicular to the source voxel, to present a suitable method to accurately calculate VSVs for larger voxel sizes. Methods: Accurate sets of VSVs for target voxel to source voxel distances up to 10 cm were obtained for high-resolution voxel sizes (0.5 mm for electrons and 1.0 mm for photons) from MC simulations for Y-90, Lu-177, and I-131 using the radiation transport code MCNPX v.2.7a. To make these values suitable to any larger voxel size, different analytical methods (based on resamplings, interpolations, and fits) were tested and compared to values obtained by direct MC simulations. As a result, an optimal calculation procedure is proposed. This procedure consisted of: (1) MC simulation for obtaining of a starting set of VSVs along a single line of voxels for a small voxel size for each radionuclide and type of radiation; (2) interpolation within the values obtained in point (1) for obtaining the VSVs for voxels within a spherical volume; (3) resampling of the data obtained in (1) and (2) for obtaining VSVs for voxels sizes larger than the one used for the MC calculation for integer voxel ratios (voxel ratio = new voxel size/voxel size MC simulation); (4) interpolation on within the data obtained in (3) for integer voxel ratios. The results were also compared to results from other authors. Results: The results obtained with the method proposed in this work show deviations relative to the source voxel below 1% for I-131 and Lu-177 and below 1.5% for Y-90 as compared with values obtained by direct MC simulations for voxel sizes ranging between 1.0 and 10.0 cm. The results obtained in this work show differences between the scored deposited energy and the emitted energy lower than 2% for electron radiation. Higher differences, attributable to the short considered radius of 10 cm in comparison with their penetration, can be found for photons. The authors' results agree well with previously published data obtained by other authors using different methods. Conclusions: A reliable and fast approach for obtaining accurate VSVs for voxel sizes larger than the voxel size used for the MC calculation of the starting set of high-resolution VSVs was developed and successfully tested for three different radionuclides of interest for targeted radiotherapy: one pure beta (Y-90) and 2 beta-gamma emitters (Lu-177 und I-131). Applying the method of this work allows any interested reader to repeat the calculations for arbitrary radionuclides of interest and/or smaller high-resolution voxel sizes, provided the means for running MC simulations are available. (C) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:8
相关论文
共 38 条
  • [21] Effective dose rate conversion coefficients for photons from radionuclides calculated using the Monte Carlo method and adult voxel phantoms
    Onat, Fatma
    Bozkurt, Ahmet
    RADIATION PHYSICS AND CHEMISTRY, 2022, 201
  • [22] A Pilot Study on the Feasibility of Real-Time Calculation of Three-Dimensional Dose Distribution for 153Sm-EDTMP Radionuclide Therapy Based on the Voxel S-Values
    Gan Feng
    Chen Lixin
    Liu Xiaowei
    Shiu Ying Tsao
    Zhang Weiguang
    Fan Wei
    CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2010, 25 (03) : 345 - 352
  • [23] Comparison of Two 90Y-charged Glass Microspheres Liver Radioembolisation Dosimetry Methods: Voxel S-values and Monte Carlo - GATE
    Ribeiro, M.
    Ferreira, P.
    Oliveira, F. P.
    Cruz, J.
    Costa, D. C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S113 - S114
  • [24] Comparison of Geant4 and MCNPX Monte Carlo systems in the calculation of voxel S values for the therapeutic radionuclides 90Y, 111In, 177Lu and 131I
    Auditore, L.
    Amato, E.
    Italiano, A.
    Minutoli, F.
    Campennil, A.
    Baldari, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S752 - S752
  • [25] Differences in 3D dose distributions due to calculation method of voxel S-values and the influence of image blurring in SPECT
    Pacilio, Massimiliano
    Amato, Ernesto
    Lanconelli, Nico
    Basile, Chiara
    Alberto Torres, Leonel
    Botta, Francesca
    Ferrari, Mahila
    Cornejo Diaz, Nestor
    Coca Perez, Marco
    Fernandez, Maria
    Lassmann, Michael
    Vergara Gil, Alex
    Cremonesi, Marta
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (05): : 1945 - 1964
  • [26] Comparison of Voxel S-values and Monte Carlo Simulation in [177Lu]Lu-DOTA-TATE Quantification for Patient-Specific Dosimetry
    Rodrigues, C.
    Ferreira, P.
    Oliveira, F. P. M.
    Silva, A.
    Peralta, L.
    Costa, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S75 - S75
  • [27] Fast beta-emitter Monte Carlo simulations and full patient dose calculations of targeted radionuclide therapy: introducing egs_mird
    Martinov, Martin P.
    Opara, Chidera
    Thomson, Rowan M.
    Lee, Ting-Yim
    MEDICAL PHYSICS, 2022, 49 (09) : 6137 - 6149
  • [28] Personalized Dosimetry for Targeted Radionuclide Therapy: Predicting Absorbed Dose from a Single Diagnostic Dynamic PET Study using Graphical Analysis and Monte Carlo Simulation
    Thanh-Tai Duong
    De Sarno, Danny
    Martinov, Martin
    Fakir, Hatim
    Bauman, Glenn
    Lee, Ting Yim
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [29] Use of fine resolution Voxel-S-Values for absorbed dose calculation from SPECT or PET based cumulated activity distributions
    Dieudonne, A.
    Bolch, W. E.
    Gardin, I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S136 - S136
  • [30] Impact of Tissue Density on Dosimetric Accuracy in 166Ho-TARE: A Comparative Analysis Using Local Energy Deposition, Voxel S-Values, and Monte Carlo Simulations
    Capotosti, A.
    De Spirito, M.
    Indovina, L.
    Iaccarino, G.
    Miseo, L.
    Moretti, R.
    Moretti, I.
    Pacilio, M.
    Sciuto, R.
    Soriani, A.
    Ungania, S.
    Cassano, B.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S208 - S208