A fast method for rescaling voxel S values for arbitrary voxel sizes in targeted radionuclide therapy from a single Monte Carlo calculation

被引:12
|
作者
Fernandez, Maria [1 ]
Haenscheid, Heribert [1 ]
Mauxion, Thibault [2 ]
Bardies, Manuel [2 ]
Kletting, Peter [3 ]
Glatting, Gerhard [4 ]
Lassmann, Michael [1 ]
机构
[1] Univ Wurzburg, Dept Nucl Med, D-97080 Wurzburg, Germany
[2] Ctr Rech Cancerol Toulouse, UPS, INSERM, UMR 1037, F-31062 Toulouse, France
[3] Univ Ulm, Dept Nucl Med, D-89081 Ulm, Germany
[4] Heidelberg Univ, Med Fac Mannheim, D-68167 Mannheim, Germany
关键词
Voxel S values (VSVs); Monte-Carlo simulation; targeted radionuclide therapy (TRT); internal dosimetry; NONUNIFORM ACTIVITY DISTRIBUTIONS; DOSE CALCULATIONS; DOSIMETRY; ENERGIES; PHANTOMS; ADULT; CODES;
D O I
10.1118/1.4812684
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In targeted radionuclide therapy, patient-specific dosimetry based on voxel S values (VSVs) is preferable to dosimetry based on mathematical phantoms. Monte-Carlo (MC) simulations are necessary to deduce VSVs for those voxel sizes required by quantitative imaging. The aim of this study is, starting from a single set of high-resolution VSVs obtained by MC simulations for a small voxel size along one single axis perpendicular to the source voxel, to present a suitable method to accurately calculate VSVs for larger voxel sizes. Methods: Accurate sets of VSVs for target voxel to source voxel distances up to 10 cm were obtained for high-resolution voxel sizes (0.5 mm for electrons and 1.0 mm for photons) from MC simulations for Y-90, Lu-177, and I-131 using the radiation transport code MCNPX v.2.7a. To make these values suitable to any larger voxel size, different analytical methods (based on resamplings, interpolations, and fits) were tested and compared to values obtained by direct MC simulations. As a result, an optimal calculation procedure is proposed. This procedure consisted of: (1) MC simulation for obtaining of a starting set of VSVs along a single line of voxels for a small voxel size for each radionuclide and type of radiation; (2) interpolation within the values obtained in point (1) for obtaining the VSVs for voxels within a spherical volume; (3) resampling of the data obtained in (1) and (2) for obtaining VSVs for voxels sizes larger than the one used for the MC calculation for integer voxel ratios (voxel ratio = new voxel size/voxel size MC simulation); (4) interpolation on within the data obtained in (3) for integer voxel ratios. The results were also compared to results from other authors. Results: The results obtained with the method proposed in this work show deviations relative to the source voxel below 1% for I-131 and Lu-177 and below 1.5% for Y-90 as compared with values obtained by direct MC simulations for voxel sizes ranging between 1.0 and 10.0 cm. The results obtained in this work show differences between the scored deposited energy and the emitted energy lower than 2% for electron radiation. Higher differences, attributable to the short considered radius of 10 cm in comparison with their penetration, can be found for photons. The authors' results agree well with previously published data obtained by other authors using different methods. Conclusions: A reliable and fast approach for obtaining accurate VSVs for voxel sizes larger than the voxel size used for the MC calculation of the starting set of high-resolution VSVs was developed and successfully tested for three different radionuclides of interest for targeted radiotherapy: one pure beta (Y-90) and 2 beta-gamma emitters (Lu-177 und I-131). Applying the method of this work allows any interested reader to repeat the calculations for arbitrary radionuclides of interest and/or smaller high-resolution voxel sizes, provided the means for running MC simulations are available. (C) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:8
相关论文
共 38 条
  • [31] A fast Monte Carlo cell-by-cell simulation for radiobiological effects in targeted radionuclide therapy using pre-calculated single-particle track standard DNA damage data
    Lim, A.
    Andriotty, M.
    Yusufaly, T.
    Agasthya, G.
    Lee, B.
    Wang, C.
    FRONTIERS IN NUCLEAR MEDICINE, 2023, 3
  • [33] The ratio of ICRP103 to ICRP60 calculated effective doses from CT: Monte Carlo calculations with the ADELAIDE voxel paediatric model and comparisons with published values
    Martin Caon
    Australasian Physical & Engineering Sciences in Medicine, 2013, 36 : 355 - 362
  • [34] A 3-dimensional absorbed dose calculation method based on quantitative SPECT for radionuclide therapy:: Evaluation for 131I using Monte Carlo simulation
    Ljungberg, M
    Sjögreen, K
    Liu, XW
    Frey, E
    Dewaraja, Y
    Strand, SE
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (08) : 1101 - 1109
  • [35] Initial Testing of an Approximated, Fast Calculation Procedure for Personalized Dosimetry in Radionuclide Therapy Based on Planar Whole-Body Scan and Monte-Carlo Specific Dose Rates from the OpenDose Project
    Bianco, Davide
    Nappi, Carmela
    Piscopo, Leandra
    Volpe, Fabio
    Manganelli, Mariarosaria
    Volpicelli, Federica
    Loffredo, Filomena
    Totaro, Pasquale
    Quarto, Maria
    Cuocolo, Alberto
    Klain, Michele
    LIFE-BASEL, 2022, 12 (09):
  • [36] Radionuclide Voxel S Values for 131I, 99mTc, 32P, 90Y, 177Lu, 153Sm, 186Re, 188Re, 18F and 82Ru calculated by means of a Geant4 Monte Carlo simulation
    Amato, E.
    Minutoli, F.
    Campenni, A.
    Baldari, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S321 - S321
  • [37] SPECT-CT imaging quantification and S-voxel method to study the dose distribution in Indium-111 and Yttrium-90 phantoms: a 3-D dosimetric model for targeted isotope-based therapy
    Fabbri, C.
    Sarti, G.
    Casi, M.
    Mattone, V.
    De lauro, F.
    Agostini, M.
    Amadori, S.
    Gentili, G.
    Tassinari, L.
    Bartolomei, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S258 - S258
  • [38] SPECT-CT imaging quantification and S-voxel method to study the dose distribution in Indium-111 and Yttrium-90 phantoms: a 3-D dosimetric model for targeted isotope-based therapy.
    Fabbri, C.
    Sarti, G.
    Casi, M.
    Mattone, V.
    De lauro, F.
    Agostini, M.
    Amadori, S.
    Gentili, G.
    Tassinari, L.
    Bartolomei, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 (SUPPL 2) : 258 - 258