Differences in 3D dose distributions due to calculation method of voxel S-values and the influence of image blurring in SPECT

被引:40
|
作者
Pacilio, Massimiliano [1 ]
Amato, Ernesto [2 ]
Lanconelli, Nico [3 ]
Basile, Chiara [1 ]
Alberto Torres, Leonel [4 ]
Botta, Francesca [5 ]
Ferrari, Mahila [5 ]
Cornejo Diaz, Nestor [6 ]
Coca Perez, Marco [4 ]
Fernandez, Maria [7 ]
Lassmann, Michael [7 ]
Vergara Gil, Alex [4 ]
Cremonesi, Marta [5 ]
机构
[1] Azienda Osped San Camillo Forlanini, Dept Med Phys, Rome, Italy
[2] Univ Messina, Sect Radiol Sci, Dept Biomed Sci & Morphol & Funct Imaging, Messina, Italy
[3] Univ Bologna, Dept Phys & Astron, Alma Mater Studiorum, Bologna, Italy
[4] Ctr Isotopes DIC CENTIS, Div Clin Res, Dept Nucl Med, Havana, Cuba
[5] Ist Europeo Oncol, Dept Med Phys, Milan, Italy
[6] Res Ctr Energy Environm & Technol, Madrid, Spain
[7] Univ Wurzburg, Dept Nucl Med, D-97070 Wurzburg, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2015年 / 60卷 / 05期
关键词
targeted radionuclide therapy; voxel S values; SPECT; Monte Carlo; partial volume effects; MONTE-CARLO CODE; POINT KERNELS; RADIONUCLIDE THERAPY; QUANTITATIVE SPECT; RADIATION-THERAPY; Y-90; MICROSPHERES; TISSUE DENSITY; DOSIMETRY; RADIOEMBOLIZATION; VALIDATION;
D O I
10.1088/0031-9155/60/5/1945
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study compares 3D dose distributions obtained with voxel S values (VSVs) for soft tissue, calculated by several methods at their current state-of-the-art, varying the degree of image blurring. The methods were: 1) convolution of Dose Point Kernel (DPK) for water, using a scaling factor method; 2) an analytical model (AM), fitting the deposited energy as a function of the source-target distance; 3) a rescaling method (RSM) based on a set of high-resolution VSVs for each isotope; 4) local energy deposition (LED). VSVs calculated by direct Monte Carlo simulations were assumed as reference. Dose distributions were calculated considering spheroidal clusters with various sizes (251, 1237 and 4139 voxels of 3 mm size), uniformly filled with I-131, Lu-177, Re-188 or Y-90. The activity distributions were blurred with Gaussian filters of various widths (6, 8 and 12 mm). Moreover, 3D-dosimetry was performed for 10 treatments with Y-90 derivatives. Cumulative Dose Volume Histograms (cDVHs) were compared, studying the differences in D-95%, D-50% or D-max (Delta D-95%, Delta D-50% and Delta D-max) and dose profiles. For unblurred spheroidal clusters, Delta D-95%, Delta D-50% and Delta Dmax were mostly within some percents, slightly higher for Lu-177 with DPK (8%) and RSM (12%) and considerably higher for LED (Delta D-95% up to 59%). Increasing the blurring, differences decreased and also LED yielded very similar results, but D-95% and D-50% underestimations between 30-60% and 15-50%, respectively (with respect to 3D-dosimetry with unblurred distributions), were evidenced. Also for clinical images (affected by blurring as well), cDVHs differences for most methods were within few percents, except for slightly higher differences with LED, and almost systematic for dose profiles with DPK (-1.2%), AM (-3.0%) and RSM (4.5%), whereas showed an oscillating trend with LED. The major concern for 3D-dosimetry on clinical SPECT images is more strongly represented by image blurring than by differences among the VSVs calculation methods. For volume sizes about 2-fold the spatial resolution, D-95% and D-50% underestimations up to about 60 and 50% could result, so the usefulness of 3D-dosimetry is highly questionable for small tumors, unless adequate corrections for partial volume effects are adopted.
引用
收藏
页码:1945 / 1964
页数:20
相关论文
共 50 条
  • [1] Impact of voxel S-values calculation method on 3D dosimetry for radionuclide therapy: application to SIRT and IART treatments
    Pacilio, M.
    Botta, F.
    Torres Aroche, L.
    Amato, E.
    Cornejo Diaz, N.
    Lanconelli, N.
    Coca Perez, M.
    Basile, C.
    Cremonesi, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S320 - S320
  • [2] Dosimetry for nonuniform activity distributions: A method for the calculation of 3D absorbed-dose distribution without the use of voxel S-values, point kernels, or Monte Carlo simulations
    Traino, A. C.
    Marcatili, S.
    Avigo, C.
    Sollini, M.
    Erba, P. A.
    Mariani, G.
    MEDICAL PHYSICS, 2013, 40 (04)
  • [3] An analytical method for computing 177Lu Voxel S-Values for 3D internal dosimetry
    Pistone, D.
    Auditore, L.
    Italiano, A.
    Amato, E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S638 - S639
  • [4] VoxelDose: A software for 3D Dosimetry in Targeted Radiotherapy using S-Values at the voxel level
    Dieudonne, A.
    Gardin, I.
    Zhang, P.
    Bolch, W. E.
    Assie, K.
    Buvat, I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S135 - S136
  • [5] DOSE CALCULATION AND OPTIMIZATION FOR 3D CONFORMAL VOXEL SCANNING
    SCHEIB, S
    PEDRONI, E
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 1992, 31 (03) : 251 - 256
  • [6] Clinical Feasibility of 3D Dosimetry using Voxel S-Values for the Treatment of HepatoCellular Carcinoma with Yttrium 90 Microspheres
    Dieudonne, A.
    Garin, E.
    Laffont, S.
    Rolland, Y.
    Lebtahi, R.
    Gardin, I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S119 - S119
  • [7] Use of fine resolution Voxel-S-Values for absorbed dose calculation from SPECT or PET based cumulated activity distributions
    Dieudonne, A.
    Bolch, W. E.
    Gardin, I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S136 - S136
  • [8] Fast 3D dosimetry of Y90 selective internal radiation treatment (SIRT) using voxel S-values
    Dieudonne, Arnaud
    Garin, Etienne
    Laffont, Sophie
    Rolland, Yan
    Lebtahi, Rachida
    Gardin, Isabelle
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [9] The Impact of Registration Method on 3D Dose Distributions
    Page, E.
    Tipping, J.
    Hamilton, D.
    Robinson, A.
    Cullen, D.
    Oldfield, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S332 - S332
  • [10] An evaluation of SPECT image reconstruction parameters for activity quantitation and absorbed dose calculation in 3D dosimetry applications
    Minarik, D.
    Sjogreen, K.
    Ljungberg, M.