The application of frequency response analysis in transformer winding distortion inspecting

被引:0
|
作者
Dai, WJ [1 ]
Liu, BB [1 ]
Yang, L [1 ]
Zhou, W [1 ]
机构
[1] Nanchang Univ, Dept Elect Engn, Nanchang 330029, Peoples R China
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Frequency response analysis (FRA) is a novelty way to monitor transformer internal winding distortions. After inputting frequency signal from one port of winding, measuring the characteristic parameter of the two ports of winding, such as inputting impedance, outputting impedance, current-transfer ratio and voltage-transfer ratio, etc., the structure character of the winding call he judged by analyzing the frequency map of terminal parameter characteristic. The use of the method is becoming more and more universal in engineering field because of its distinct superiority. The paper introduces the whole procedure of the way to test the distortion status of the transformer winding, that is, the basic principle of the frequency response analysis, the range of the test frequency, the amount choice of the scan, the influence factors in the test and the way to judge the result of the test. At the end, the paper presents the true examples of the original curve getting from certain power supply corporation in Jiangxi Province.
引用
收藏
页码:1759 / 1762
页数:4
相关论文
共 50 条
  • [41] Locating Inter-disc Faults in Transformer Winding Using Frequency Response Analysis
    Yousof, M. F. M.
    Ekanayake, C.
    Saha, T. K.
    2013 AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC), 2013,
  • [42] Double-End Excitation of Transformer Winding Model for Improved Frequency Response Analysis
    Pramanik, Saurav
    Ganesh, Aravind
    PROCEEDINGS OF THE 21ST INTERNATIONAL SYMPOSIUM ON HIGH VOLTAGE ENGINEERING, VOL 1, 2020, 598 : 594 - 605
  • [43] Novel method for detection of transformer winding faults using Sweep Frequency Response Analysis
    Singh, Jashandeep
    Sood, Yog Raj
    Verma, Piush
    Jarial, Raj Kumar
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 2949 - +
  • [44] BA to construction of equivalent circuit of a transformer winding from frequency response analysis measurement
    Chaouche, Moustafa Sahnoune
    Houassine, Hamza
    Moulahoum, Samir
    Colak, Ilhami
    IET ELECTRIC POWER APPLICATIONS, 2018, 12 (05) : 728 - 736
  • [45] Diagnosis Method of Power Transformer Winding Position Deviation based on Frequency Response Analysis
    Song, Xi
    Zhang, Hehui
    Li, Wenhui
    Liu, Jixiang
    Song, Renping
    Wang, Bo
    Yin, Qiang
    Journal of Network Intelligence, 2022, 7 (01): : 243 - 259
  • [46] Frequency Response and Vibration Analysis in Transformer Winding Turn-to-Turn Fault Recognition
    Bagheri, M.
    Phung, B. T.
    2016 INTERNATIONAL CONFERENCE ON SMART GREEN TECHNOLOGY IN ELECTRICAL AND INFORMATION SYSTEMS (ICSGTEIS), 2016, : 10 - 15
  • [47] Enhanced modelling of the transformer winding high frequency parameters identification from measured frequency response analysis
    Chanane, Abdallah
    Houassine, Hamza
    Bouchhida, Ouahid
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2019, 13 (08) : 1339 - 1345
  • [48] Prediction of Transformer Winding Displacement from Frequency Response Characteristics
    Sathya, M. Arul
    Thomas, Ajith John
    Usa, S.
    2013 IEEE 1ST INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS (CATCON), 2013, : 303 - 307
  • [49] A Bootstrapping Solution for Effective Interpretation of Transformer Winding Frequency Response
    Akhmetov, Yerbol
    Nurmanova, Venera
    Bagheri, Mehdi
    Zollanvari, Amin
    Gharehpetian, Gevork B.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [50] Deformation Study of a Transformer Winding using Frequency-Response Analysis and Finite-Element Analysis
    Pradhan, Sibabrata
    Nayak, Sisir Kumar
    2022 22ND NATIONAL POWER SYSTEMS CONFERENCE, NPSC, 2022,