The application of frequency response analysis in transformer winding distortion inspecting

被引:0
|
作者
Dai, WJ [1 ]
Liu, BB [1 ]
Yang, L [1 ]
Zhou, W [1 ]
机构
[1] Nanchang Univ, Dept Elect Engn, Nanchang 330029, Peoples R China
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Frequency response analysis (FRA) is a novelty way to monitor transformer internal winding distortions. After inputting frequency signal from one port of winding, measuring the characteristic parameter of the two ports of winding, such as inputting impedance, outputting impedance, current-transfer ratio and voltage-transfer ratio, etc., the structure character of the winding call he judged by analyzing the frequency map of terminal parameter characteristic. The use of the method is becoming more and more universal in engineering field because of its distinct superiority. The paper introduces the whole procedure of the way to test the distortion status of the transformer winding, that is, the basic principle of the frequency response analysis, the range of the test frequency, the amount choice of the scan, the influence factors in the test and the way to judge the result of the test. At the end, the paper presents the true examples of the original curve getting from certain power supply corporation in Jiangxi Province.
引用
收藏
页码:1759 / 1762
页数:4
相关论文
共 50 条
  • [21] Influence of Moisture Content Variation on Frequency Response Analysis of Transformer Winding
    Bagheri, Mehdi
    Phung, B. T.
    Blackburn, Trevor
    2014 ELECTRICAL INSULATION CONFERENCE (EIC), 2014, : 333 - 337
  • [22] Effect of Temperature Properties of Transformer Materials on Frequency Response Analysis of Winding
    Wang G.
    Niu C.
    Wang L.
    Li Y.
    Ye J.
    Wang T.
    Luo Y.
    He L.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2020, 40 (03): : 999 - 1008
  • [23] A Study on Suitability of Different Transformer Winding Models for Frequency Response Analysis
    Yousof, M. F. M.
    Ekanayake, Chandima
    Saha, Tapan K.
    Ma, Hui
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [24] Based on Short-time Fourier Transform Impulse Frequency Response Analysis in the Application of the Transformer Winding Deformation
    Li, Yaning
    Peng, Wenbang
    Zhu, Xiaoyan
    Wei, Genyuan
    Yu, Hong
    Qian, Guochao
    2016 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2016, : 371 - 375
  • [25] Estimation of Transformer Winding Capacitances through Frequency Response Analysis - An Experimental Investigation
    Shah, Krupa
    Ragavan, K.
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2013, 14 (06): : 549 - 559
  • [26] Investigation of Transformer Model Winding Deformation Using Sweep Frequency Response Analysis
    Ludwikowski, K.
    Siodla, K.
    Ziomek, W.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (06) : 1957 - 1961
  • [27] Modeling of a power transformer winding for deformation detection based on frequency response analysis
    Almas, Shintemirov
    Tang, Wenhu
    Wu, Q. H.
    PROCEEDINGS OF THE 26TH CHINESE CONTROL CONFERENCE, VOL 5, 2007, : 506 - +
  • [28] The Effect of Winding Design on Transformer Frequency Response with Application on Offshore Wind Farm Energization
    Soloot, Amir Hayati
    Hoidalen, Hans Kristian
    Gustavsen, Bjorn
    INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA), 2012,
  • [29] Detection and quantitative diagnosis of axial displacement of transformer winding by frequency response analysis
    Miyazaki, Satoru
    Tahir, Mehran
    Tenbohlen, Stefan
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2019, 13 (15) : 3493 - 3500
  • [30] Bushing Characteristic Impacts on On-line Frequency Response Analysis of Transformer Winding
    Bagheri, Mehdi
    Naderi, Mohammad Salay
    Blackburn, Trevor
    Phung, B. T.
    2012 IEEE INTERNATIONAL CONFERENCE ON POWER AND ENERGY (PECON), 2012, : 956 - 961