The application of frequency response analysis in transformer winding distortion inspecting

被引:0
|
作者
Dai, WJ [1 ]
Liu, BB [1 ]
Yang, L [1 ]
Zhou, W [1 ]
机构
[1] Nanchang Univ, Dept Elect Engn, Nanchang 330029, Peoples R China
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Frequency response analysis (FRA) is a novelty way to monitor transformer internal winding distortions. After inputting frequency signal from one port of winding, measuring the characteristic parameter of the two ports of winding, such as inputting impedance, outputting impedance, current-transfer ratio and voltage-transfer ratio, etc., the structure character of the winding call he judged by analyzing the frequency map of terminal parameter characteristic. The use of the method is becoming more and more universal in engineering field because of its distinct superiority. The paper introduces the whole procedure of the way to test the distortion status of the transformer winding, that is, the basic principle of the frequency response analysis, the range of the test frequency, the amount choice of the scan, the influence factors in the test and the way to judge the result of the test. At the end, the paper presents the true examples of the original curve getting from certain power supply corporation in Jiangxi Province.
引用
收藏
页码:1759 / 1762
页数:4
相关论文
共 50 条
  • [31] Transformer Winding Deformation Diagnosis Using Middle Band Frequency Response Analysis
    Li, Yanming
    Liu, Gang
    Pang, Linhai
    Zhang, Longjun
    Lin, Zhiming
    2007 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2007, : 677 - +
  • [32] Diagnosis of Winding Displacement in Power Transformer Using Frequency Response Analysis Technique
    Talib, Mohd Aizam
    Saeidi, Nurul Atikah
    Munim, Wan Noraishah Wan Abdul
    PROCEEDINGS OF THE 2013 IEEE 7TH INTERNATIONAL POWER ENGINEERING AND OPTIMIZATION CONFERENCE (PEOCO2013), 2013, : 315 - 318
  • [33] Transformer winding condition assessment using frequency response analysis and evidential reasoning
    Shintemirov, A.
    Tang, W. H.
    Wu, Q. H.
    IET ELECTRIC POWER APPLICATIONS, 2010, 4 (03) : 198 - 212
  • [34] Analysis of Transformer Winding High Frequency Characteristics
    Fan Songhai
    Wang, Zijian
    Quan, YuSheng
    2016 INTERNATIONAL CONFERENCE ON POWER ENGINEERING & ENERGY, ENVIRONMENT (PEEE 2016), 2016, : 127 - 132
  • [35] Frequency domain analysis of the transient in the transformer winding
    Tsinghua Univ, Beijing, China
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 1995, 35 (01): : 39 - 45
  • [36] Modeling of frequency response of transformer winding with axial deformations
    Gawrylczyk, K. M.
    Banaszak, S.
    ARCHIVES OF ELECTRICAL ENGINEERING, 2014, 63 (01) : 5 - 17
  • [37] Diagnosis and Identification of Transformer Winding Faults from Frequency Response Data by the Application of ANN Technique
    Prameela, M.
    Murthy, G. Radhakrishna
    Nirgude, Pradeep M.
    2012 IEEE 10TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS (ICPADM), 2012,
  • [38] Abnormality Diagnosis of Transformer Winding by Frequency Response Analysis (FRA) Using Circuit Model
    Miyazaki, Satoru
    Mizutani, Yoshinobu
    Okamoto, Tatsuki
    Wada, Yoshihiro
    Hayashida, Chikara
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 273 - 276
  • [39] Sensitivity of Connection Schemes for Detection of Axial Displacement of Transformer Winding by Frequency Response Analysis
    Miyazaki, S.
    Tahir, M.
    Tenbohlen, S.
    2018 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2018,
  • [40] Using the Vibration Frequency Response Analysis Method to Detect the Winding Deformation of Power Transformer
    Wang, F. H.
    Jin, Z. J.
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,