The application of frequency response analysis in transformer winding distortion inspecting

被引:0
|
作者
Dai, WJ [1 ]
Liu, BB [1 ]
Yang, L [1 ]
Zhou, W [1 ]
机构
[1] Nanchang Univ, Dept Elect Engn, Nanchang 330029, Peoples R China
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Frequency response analysis (FRA) is a novelty way to monitor transformer internal winding distortions. After inputting frequency signal from one port of winding, measuring the characteristic parameter of the two ports of winding, such as inputting impedance, outputting impedance, current-transfer ratio and voltage-transfer ratio, etc., the structure character of the winding call he judged by analyzing the frequency map of terminal parameter characteristic. The use of the method is becoming more and more universal in engineering field because of its distinct superiority. The paper introduces the whole procedure of the way to test the distortion status of the transformer winding, that is, the basic principle of the frequency response analysis, the range of the test frequency, the amount choice of the scan, the influence factors in the test and the way to judge the result of the test. At the end, the paper presents the true examples of the original curve getting from certain power supply corporation in Jiangxi Province.
引用
收藏
页码:1759 / 1762
页数:4
相关论文
共 50 条
  • [1] A novelty instrument inspecting transformer winding distortion based on frequency response analysis
    Dai, WJ
    Zhou, W
    Liu, BB
    ICEMI 2005: Conference Proceedings of the Seventh International Conference on Electronic Measurement & Instruments, Vol 3, 2005, : 21 - 25
  • [2] The analysis of factors influencing the Frequency Response of the transformer winding
    Banaszak, Szymon
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (11A):
  • [3] Study of Transformer Winding Deformation by Frequency Response Analysis
    Yousof, M. F. M.
    Ekanayake, C.
    Saha, T. K.
    2013 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PES), 2013,
  • [4] Frequency Response Analysis to Investigate Deformation of Transformer Winding
    Yousof, M. Fairouz M.
    Ekanayake, Chandima
    Saha, Tapan K.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (04) : 2359 - 2367
  • [5] Influence of Temperature on Frequency Response Analysis of Transformer Winding
    Bagheri, Mehdi
    Phung, B. T.
    Blackburn, Trevor
    Naderian, Ali
    2013 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2013, : 40 - 44
  • [6] Fault Diagnostic in the Transformer Winding by Sweep Frequency Response Analysis
    Kumar, Abhishek
    Aggarwal, Priyanshi
    Kumbhar, Ganesh B.
    Bhalja, Bhavesh R.
    4TH INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS (CATCON 2019), 2019,
  • [7] Detection of deformation and displacement of transformer winding by Frequency Response Analysis
    Miyazaki, Satoru
    Mizutani, Yoshinobu
    Suzuki, Hiroshi
    Ichikawa, Michiharu
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 964 - 967
  • [8] On-site diagnosis of transformer winding by frequency Response Analysis
    Miyazaki S.
    Mizutani Y.
    Matsumoto K.
    Nakamura S.
    IEEJ Transactions on Power and Energy, 2010, 130 (04) : 451 - 459+8
  • [9] Investigating the Sensitivity of Frequency Response Analysis on Transformer Winding Structure
    Yousof, M. F. M.
    Saha, T. K.
    Ekanayake, C.
    2014 IEEE PES GENERAL MEETING - CONFERENCE & EXPOSITION, 2014,
  • [10] Instrument Transformer Winding Fault Analysis Using Frequency Response Analysis
    Premalatha, V
    Sruthi, S. S.
    Vikash, M.
    Ilampoornan, M. K.
    2012 IEEE INTERNATIONAL CONFERENCE ON ADVANCED COMMUNICATION CONTROL AND COMPUTING TECHNOLOGIES (ICACCCT), 2012, : 370 - 374