Evaluation of an automated immunoassay method for cytokine measurement using the Immulite® immunoassay system

被引:45
|
作者
Berthier, F
Lambert, C
Genin, C
Bienvenu, J [1 ]
机构
[1] Ctr Hosp Lyon Sud, Immunol Lab, F-69495 Pierre Benite, France
[2] CHU St Etienne, Immunol Lab, St Etienne, France
关键词
cytokines; immunoassay; automation; method evaluation;
D O I
10.1515/CCLM.1999.092
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Cytokines are key mediators in cell regulation and communication. The concentration of these proteins can rapidly and importantly increase during severe clinical situations. However, current techniques are not adapted to stat measurement, thus making their clinical use limited. In this context, the commercialization of five new kits for cytokine measurement interleukin ((IL)-1, IL-6, IL-8, tumor necrosis factor (TNF)-alpha and IL-2R) on an automated immunoanalyzer, the Immulite(R), seems to be a new approach for the determination of these markers. We report here the evaluation of the performance of these tests. The technique is based on a solid phase (bead) two site chemiluminescent enzyme immunometric assay. The analysis is performed within 60 to 90 minutes and the calibration is stable for 15 days. The values of the between-run imprecision study were similar to those from the within-run study with coefficients of variation (CV) ranging from 2% (low values of IL-8) to 11.5 % for intermediate concentrations of IL-6 (500 pg/ml). CVs were usually around 5 %. The accuracy was determined by a linearity study using standards (except for IL-2R) provided by the National Institute for biological Standards and Control (NIBSC). Slopes obtained during this study were close to 1 (r(2) = 0.99), except for IL-6, for which the slope was 1.55. TNF-alpha values were close to those expected. IL-1 results were about 20 % higher. IL-6 values were over estimated above 100 pg/ml and under estimated below this value. IL-8 study seemed to be impaired by the poor stability of this molecule in the NIBSC preparation. Correlation study with standard laboratory techniques gave variable results : for IL-1 (n = 43) the slope was 0.77 (study carried out using cell culture media), for IL-6 (n = 54) the slope was 0.78, for IL-8 (n = 37) the slope was 1.64, for TNF-alpha (n = 40) the slope was 0.33 and the slope for IL-2R (n = 51) was 5.1. For the last cytokine, the unit in Immulite assay was different from the one used in our comparison technique. Cross-calibration results were consistent with these data and show that the bias is probably linked to a calibration problem. The study demonstrated excellent practicality of the system, and good stability of the calibration curve (15 days). However, the sample volume required (350 mu l for the IL-6 and the TNF-alpha) could constitute a limitation for pediatric measurements.
引用
收藏
页码:593 / 599
页数:7
相关论文
共 50 条
  • [41] Evaluation of C-peptide by chemiluminescent immunoassay on the IMMULITE(R) analyzer
    Swanson, KH
    Haven, MC
    [J]. CLINICAL CHEMISTRY, 1996, 42 (06) : 93 - 93
  • [42] Performance evaluation of an automated immunoassay for the determination of Cortisol on the Olympus AU3000i™ Immunoassay System
    Evans, M.
    O'Sullivan, A.
    Hennessey, S.
    Hanley, J.
    Gaston, S.
    [J]. CLINICAL CHEMISTRY, 2009, 55 (06) : A188 - A189
  • [43] Performance evaluation of an automated immunoassay for the determination of estradiol on the Olympus AU3000i™ Immunoassay System
    O'Dea, P.
    Curley, P.
    de Rochebouet, B. de Grimaudet
    O'Sullivan, A.
    Gaston, S.
    [J]. CLINICAL CHEMISTRY, 2009, 55 (06) : A189 - A189
  • [44] Performance Evaluation of an Automated Fentanyl Immunoassay
    Tang, Mei San
    Lloyd, Matthew
    Williams, Monette
    Farnsworth, Christopher W.
    Budelier, Melissa M.
    [J]. JOURNAL OF APPLIED LABORATORY MEDICINE, 2021, 6 (05): : 1192 - 1201
  • [45] AN EVALUATION OF A FULLY AUTOMATED IMMUNOASSAY OF THYROXINE
    VUORINEN, P
    HARMOINEN, A
    JOKELA, H
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1986, 46 : 134 - 134
  • [46] Measurement of sirolimus concentrations in human blood using an automated electrochemiluminescence immunoassay (ECLIA): a multicenter evaluation
    Stove, Veronique
    Ramos, Pedro Alia
    Wallemacq, Pierre
    Vogeser, Michael
    Schuetzenmeister, Andre
    Schmiedel, Christian
    Shipkova, Maria
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2018, 56 (05) : 764 - 775
  • [47] Measurement of late-night salivary cortisol with an automated immunoassay system
    Vogeser, Michael
    Durner, Juergen
    Seliger, Ewald
    Auernhammer, Christoph
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2006, 44 (12) : 1441 - 1445
  • [48] Measurement of late-night salivary cortisol with an automated immunoassay system
    Vogeser, M.
    Seliger, E.
    Durner, J.
    Auernhammer, C.
    [J]. EXPERIMENTAL AND CLINICAL ENDOCRINOLOGY & DIABETES, 2007, 115 : S68 - S69
  • [49] Analytical performances of the D-dimer assay for the immulite 2000 automated immunoassay analyser
    Lippi, G.
    Salvagno, G. L.
    Rossi, L.
    Montagnana, M.
    Franchini, M.
    Guidi, G. C.
    [J]. INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2007, 29 (06) : 415 - 420
  • [50] THE ANAGEN SYSTEM FOR AUTOMATED FLUOROMETRIC IMMUNOASSAY
    CLEMENTS, JA
    FORREST, GC
    JAY, RF
    JEFFERY, M
    KEMP, PM
    KJELDSEN, NJ
    RATTLE, SJ
    SMITH, A
    [J]. CLINICAL CHEMISTRY, 1992, 38 (09) : 1671 - 1677