Evaluation of an automated immunoassay method for cytokine measurement using the Immulite® immunoassay system

被引:45
|
作者
Berthier, F
Lambert, C
Genin, C
Bienvenu, J [1 ]
机构
[1] Ctr Hosp Lyon Sud, Immunol Lab, F-69495 Pierre Benite, France
[2] CHU St Etienne, Immunol Lab, St Etienne, France
关键词
cytokines; immunoassay; automation; method evaluation;
D O I
10.1515/CCLM.1999.092
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Cytokines are key mediators in cell regulation and communication. The concentration of these proteins can rapidly and importantly increase during severe clinical situations. However, current techniques are not adapted to stat measurement, thus making their clinical use limited. In this context, the commercialization of five new kits for cytokine measurement interleukin ((IL)-1, IL-6, IL-8, tumor necrosis factor (TNF)-alpha and IL-2R) on an automated immunoanalyzer, the Immulite(R), seems to be a new approach for the determination of these markers. We report here the evaluation of the performance of these tests. The technique is based on a solid phase (bead) two site chemiluminescent enzyme immunometric assay. The analysis is performed within 60 to 90 minutes and the calibration is stable for 15 days. The values of the between-run imprecision study were similar to those from the within-run study with coefficients of variation (CV) ranging from 2% (low values of IL-8) to 11.5 % for intermediate concentrations of IL-6 (500 pg/ml). CVs were usually around 5 %. The accuracy was determined by a linearity study using standards (except for IL-2R) provided by the National Institute for biological Standards and Control (NIBSC). Slopes obtained during this study were close to 1 (r(2) = 0.99), except for IL-6, for which the slope was 1.55. TNF-alpha values were close to those expected. IL-1 results were about 20 % higher. IL-6 values were over estimated above 100 pg/ml and under estimated below this value. IL-8 study seemed to be impaired by the poor stability of this molecule in the NIBSC preparation. Correlation study with standard laboratory techniques gave variable results : for IL-1 (n = 43) the slope was 0.77 (study carried out using cell culture media), for IL-6 (n = 54) the slope was 0.78, for IL-8 (n = 37) the slope was 1.64, for TNF-alpha (n = 40) the slope was 0.33 and the slope for IL-2R (n = 51) was 5.1. For the last cytokine, the unit in Immulite assay was different from the one used in our comparison technique. Cross-calibration results were consistent with these data and show that the bias is probably linked to a calibration problem. The study demonstrated excellent practicality of the system, and good stability of the calibration curve (15 days). However, the sample volume required (350 mu l for the IL-6 and the TNF-alpha) could constitute a limitation for pediatric measurements.
引用
收藏
页码:593 / 599
页数:7
相关论文
共 50 条
  • [31] EVALUATION OF THE DPC IMMULITE RANDOM-ACCESS IMMUNOASSAY ANALYZER
    COSTONGS, GMPJ
    VANOERS, RJM
    LEERKES, B
    JANSON, PCW
    [J]. EUROPEAN JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1995, 33 (11): : 887 - 892
  • [32] AUTOMATED FLUORESCENCE IMMUNOASSAY SYSTEM - ITS APPLICATION AND EVALUATION
    FU, PC
    ZIC, V
    RIEDEL, B
    [J]. CLINICAL CHEMISTRY, 1982, 28 (07) : 1612 - 1612
  • [33] Analytical evaluation of C-peptide immunoassay on Immulite 2500
    Huang, Y.
    Kilmartin, C.
    McGuigan, A.
    Hannah, S.
    Turner, J.
    Donahoe, M.
    Hill, S.
    [J]. CLINICAL BIOCHEMISTRY, 2008, 41 (14-15) : 1269 - 1270
  • [34] Evaluation of anti HBs and anti HBc chemiluminescent enzyme immunoassay on the IMMULITE® system.
    Emanuelli, B
    Crapanzano, C
    Mazzocchi, GC
    Cecchettin, M
    [J]. CLINICAL CHEMISTRY, 1999, 45 (06) : A158 - A159
  • [35] Performance Evaluation of a Fully Automated Immunoassay for the Detection of Human Growth Hormone on the Elecsys® Immunoassay System
    van Helden, Josef
    Hermsen, Derek
    von Ahsen, Nicholas
    Bidlingmaier, Martin
    [J]. CLINICAL LABORATORY, 2014, 60 (10) : 1641 - 1651
  • [36] An evaluation of the benefits of multiplexed immunoassays using the Bioplex™ 2200 automated immunoassay system
    Blecka, L
    Binder, S
    Marr, G
    Mantha, G
    [J]. CLINICA CHIMICA ACTA, 2005, 355 : S366 - S366
  • [37] Development of an IMMULITE® automated chemiluminescent immunoassay for free estriol in maternal serum.
    Huang, P
    Lei, JD
    El Shami, AS
    [J]. CLINICAL CHEMISTRY, 1999, 45 (06) : A92 - A92
  • [38] Evaluation or total testosterone by chemiluminescent immunoassay on the IMMULITE(R) analyzer.
    Swanson, KH
    Haven, MC
    [J]. CLINICAL CHEMISTRY, 1997, 43 : 300 - 300
  • [39] MEASUREMENT OF SALIVARY CORTISOL LEVELS BY AN AUTOMATED ELECTROCHEMILUMINESCENCE IMMUNOASSAY METHOD (ECLIA): EVALUATION OF ANALYTICAL PERFORMANCE
    Andjelkovic, Z.
    Vuckovic, S.
    Stojanovic, J.
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S414 - S414
  • [40] EVALUATION OF THYROID-FUNCTION TESTS ON THE IMMULITE CHEMILUMINESCENT IMMUNOASSAY ANALYZER
    OLBERDING, ML
    HAVEN, MC
    [J]. CLINICAL CHEMISTRY, 1995, 41 (06) : S84 - S84