Evaluation of an automated immunoassay method for cytokine measurement using the Immulite® immunoassay system

被引:45
|
作者
Berthier, F
Lambert, C
Genin, C
Bienvenu, J [1 ]
机构
[1] Ctr Hosp Lyon Sud, Immunol Lab, F-69495 Pierre Benite, France
[2] CHU St Etienne, Immunol Lab, St Etienne, France
关键词
cytokines; immunoassay; automation; method evaluation;
D O I
10.1515/CCLM.1999.092
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Cytokines are key mediators in cell regulation and communication. The concentration of these proteins can rapidly and importantly increase during severe clinical situations. However, current techniques are not adapted to stat measurement, thus making their clinical use limited. In this context, the commercialization of five new kits for cytokine measurement interleukin ((IL)-1, IL-6, IL-8, tumor necrosis factor (TNF)-alpha and IL-2R) on an automated immunoanalyzer, the Immulite(R), seems to be a new approach for the determination of these markers. We report here the evaluation of the performance of these tests. The technique is based on a solid phase (bead) two site chemiluminescent enzyme immunometric assay. The analysis is performed within 60 to 90 minutes and the calibration is stable for 15 days. The values of the between-run imprecision study were similar to those from the within-run study with coefficients of variation (CV) ranging from 2% (low values of IL-8) to 11.5 % for intermediate concentrations of IL-6 (500 pg/ml). CVs were usually around 5 %. The accuracy was determined by a linearity study using standards (except for IL-2R) provided by the National Institute for biological Standards and Control (NIBSC). Slopes obtained during this study were close to 1 (r(2) = 0.99), except for IL-6, for which the slope was 1.55. TNF-alpha values were close to those expected. IL-1 results were about 20 % higher. IL-6 values were over estimated above 100 pg/ml and under estimated below this value. IL-8 study seemed to be impaired by the poor stability of this molecule in the NIBSC preparation. Correlation study with standard laboratory techniques gave variable results : for IL-1 (n = 43) the slope was 0.77 (study carried out using cell culture media), for IL-6 (n = 54) the slope was 0.78, for IL-8 (n = 37) the slope was 1.64, for TNF-alpha (n = 40) the slope was 0.33 and the slope for IL-2R (n = 51) was 5.1. For the last cytokine, the unit in Immulite assay was different from the one used in our comparison technique. Cross-calibration results were consistent with these data and show that the bias is probably linked to a calibration problem. The study demonstrated excellent practicality of the system, and good stability of the calibration curve (15 days). However, the sample volume required (350 mu l for the IL-6 and the TNF-alpha) could constitute a limitation for pediatric measurements.
引用
收藏
页码:593 / 599
页数:7
相关论文
共 50 条
  • [21] Automated chemiluminescent immunoassays for dsDNA antibody on the IMMULITE® 2000 and IMMULITE® 2500 immunoassay analyzers
    Qiu, B.
    Whitters, E.
    Lei, J.
    Thompson, S.
    Campbell, B.
    Jaggi, K.
    Sustarsic, D.
    [J]. CLINICAL CHEMISTRY, 2006, 52 (06) : A146 - A146
  • [22] Method evaluation of an automated fecal calprotectin immunoassay
    Miller, Jessica
    Henderson, Tina
    Jung, Benjamin P.
    Adeli, Khosrow
    Sepiashvili, Lusia
    [J]. CLINICAL BIOCHEMISTRY, 2022, 109 : 111 - 111
  • [23] A more sensitive specific estradiol assay for IMMULITE, an automated chemiluminescent immunoassay system.
    Reichstein, E
    Arkell, A
    Palomares, Q
    [J]. CLINICAL CHEMISTRY, 1998, 44 : A155 - A155
  • [24] A cross-sectional study of treated and untreated postmenopausal women using the IMMULITE® automated immunoassay system.
    Vankrieken, L
    Beukeveld, J
    Schreurs, C
    Dinant, GJ
    Geusens, P
    Durham, AP
    El Shami, AS
    [J]. CLINICAL CHEMISTRY, 2002, 48 (06) : A136 - A137
  • [25] Development of an automated chemiluminescent immunoassay for intact osteocalcin on the IMMULITE® 2000 and IMMULITE® 2500 analyzers.
    Zhong, D.
    Whitters, E.
    Lei, J.
    Panosian-Sahakian, N.
    Jaggi, K.
    Sustarsic, D.
    [J]. CLINICAL CHEMISTRY, 2006, 52 (06) : A103 - A103
  • [26] Assessment of an automated chemiluminescent immunoassay for D-dimer on the IMMULITE® 1000 Turbo, IMMULITE® 2000 and IMMULITE® 2500 analyzers
    Schaub, A.
    Li, F.
    Whitters, E.
    Lei, J.
    Sustarsic, D.
    [J]. CLINICAL CHEMISTRY, 2007, 53 (06) : A2 - A2
  • [27] Specific amphetamine and methamphetamine assays for the IMMULITE® automated immunoassay analyzer.
    Whitters, E
    Lei, JD
    Laroya, R
    Adams, S
    Unver, E
    Panosian-Sahakian, N
    El Shami, AS
    [J]. CLINICAL CHEMISTRY, 1999, 45 (06) : A120 - A121
  • [28] Clinical evaluation of cardiac troponin I (cTnI) measurement using the Stratus CS and Immulite immunoassay systems.
    Gaze, DC
    Collinson, PO
    [J]. CLINICAL CHEMISTRY, 2001, 47 (06) : A201 - A201
  • [29] Highly sensitive thyroglobulin assay for the immulite automated immunoassay analyzer.
    Whitters, E
    Lei, JD
    Knadler, L
    PanosianSahakian, N
    Unver, E
    ElShami, AS
    [J]. CLINICAL CHEMISTRY, 1997, 43 : 326 - 326
  • [30] Evaluation of hGH by chemiluminescent immunoassay on the IMMULITE(R) analyzer.
    Swanson, KH
    Haven, MC
    [J]. CLINICAL CHEMISTRY, 1997, 43 : 299 - 299