Comparison between a flash glucose monitoring system and a portable blood glucose meter for monitoring dogs with diabetes mellitus

被引:24
|
作者
Del Baldo, Francesca [1 ]
Canton, Claudia [1 ]
Testa, Silvia [1 ]
Swales, Harry [2 ]
Drudi, Ignazio [3 ]
Golinelli, Stefania [1 ]
Fracassi, Federico [1 ]
机构
[1] Univ Bologna, Dept Vet Med Sci, Via Tolara di Sopra 50, I-40064 Bologna, Italy
[2] Univ Liverpool, Small Anim Teaching Hosp, Leahurst Campus, Wirral, Merseyside, England
[3] Univ Bologna, Dept Stat Sci, Bologna, Italy
关键词
canine; diabetes mellitus; FreeStyle Libre; interstitial glucose; TO-DAY VARIATION; GLYCEMIC VARIABILITY; INTERSTITIAL GLUCOSE; SENSING TECHNOLOGY; GROWTH-HORMONE; REAL-LIFE; INSULIN; TYPE-1; HYPOGLYCEMIA; MULTICENTER;
D O I
10.1111/jvim.15930
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background Flash glucose monitoring system (FGMS; FreeStyle Libre) was recently validated for use in diabetic dogs (DD). It is not known if this system is clinically useful in monitoring DD. Objective To compare the clinical utility of FGMS against blood glucose curves (BGCs) obtained with a portable blood glucose meter (PBGM) in monitoring DD. Animals Twenty dogs with diabetes mellitus. Methods Prospective study. Dogs with diabetes mellitus on insulin treatment for at least 1 month were included. Comparisons of insulin dose recommendations based on the in-hospital GCs acquired using FGMS and a PBGM, consecutive-day interstitial GCs (IGCs) acquired at home using the FGMS, and consecutive-day, home vs hospital IGCs acquired using the FGMS were made using concordance analysis. Results There was good concordance between insulin dose recommendations based on FGMS and PBGM generated GCs and IGCs obtained in the 2 different environments on 2 consecutive days, but almost absent concordance between IGCs obtained on 2 consecutive days at home. Glucose nadirs were detected in 34/43 (79%) of Ambulatory Glucose Profile (AGP) reports of the FGMS. In comparison, concordant glucose nadirs were identified in 14/34 (41%) BGCs using PBGM. The individual FGMS scans and PBGM identified 60% and 9% of low IG/hypoglycemic episodes, respectively. Conclusions and Clinical Importance Insulin dose adjustments based on BGCs can be suboptimal. The FGMS allows a more accurate identification of the glucose nadirs and hypoglycemic episodes compared to the use of a PBGM and assessment of day-to-day variations in glycemic control.
引用
收藏
页码:2296 / 2305
页数:10
相关论文
共 50 条
  • [31] Correlation Between Blood Glucose Indexes Generated by the Flash Glucose Monitoring System and Diabetic Vascular Complications
    Sheng, Xia
    Li, Ting
    Hu, Yi
    Xiong, Cheng-Shun
    Hu, Ling
    DIABETES METABOLIC SYNDROME AND OBESITY, 2023, 16 : 2447 - 2456
  • [32] Comparison of a human portable blood glucose meter and automated chemistry analyser for measurement of blood glucose concentrations in healthy dogs
    Ismail-Hamdi, Sihem
    Romdane, Mohamed Nejib
    Ben Romdhane, Samir
    VETERINARY MEDICINE AND SCIENCE, 2021, 7 (06) : 2185 - 2190
  • [33] Use of continuous blood glucose monitoring for animals with diabetes mellitus
    DeClue, Amy E.
    Cohn, Leah A.
    Kerl, Marie E.
    Wiedmeyer, Charles E.
    JOURNAL OF THE AMERICAN ANIMAL HOSPITAL ASSOCIATION, 2004, 40 (03) : 171 - 173
  • [34] Glucose monitoring in a cat with diabetes mellitus
    Moretti, S.
    PRAKTISCHE TIERARZT, 2009, 90 (05): : 423 - 423
  • [35] Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations
    Del Baldo, Francesca
    Fracassi, Federico
    Pires, Jully
    Tardo, Antonio Maria
    Malerba, Eleonora
    Manassero, Elisa
    Gilor, Chen
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2021, 35 (03) : 1279 - 1287
  • [36] Self-monitoring of blood glucose in gestational diabetes mellitus
    Fontaine, P
    DIABETES & METABOLISM, 2003, 29 (02) : S37 - S41
  • [37] Home monitoring of blood glucose concentration in the management of diabetes mellitus
    Reusch, CE
    Wess, G
    Casella, M
    COMPENDIUM ON CONTINUING EDUCATION FOR THE PRACTICING VETERINARIAN, 2001, 23 (06): : 544 - +
  • [38] HOME BLOOD GLUCOSE MONITORING IN TYPE 1 DIABETES MELLITUS
    Alves Grossi, Sonia Aurora
    Lottenberg, Simao Augusto
    Lottenberg, Ana Maria
    Della Manna, Thais
    Kuperman, Hilton
    REVISTA LATINO-AMERICANA DE ENFERMAGEM, 2009, 17 (02): : 194 - 200
  • [39] BEYOND MONITORING: VALIDATION OF THE STATSTRIP GLUCOSE METER AS A DIAGNOSTIC TOOL FOR DIABETES MELLITUS
    Lovrencic, M. Vucic
    Biljak, V. Radisic
    Pape-Medvidovic, E.
    Bozicevic, S.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 : A75 - A76
  • [40] Evaluation of blood glucose fluctuation in Japanese patients with type 1 diabetes mellitus by self-monitoring of blood glucose and continuous glucose monitoring
    Kusunoki, Yoshiki
    Katsuno, Tomoyuki
    Nakae, Rie
    Watanabe, Kahori
    Akagami, Takafumi
    Ochi, Fumihiro
    Tokuda, Masaru
    Murai, Kazuki
    Miuchi, Masayuki
    Miyagawa, Jun-ichiro
    Namba, Mitsuyoshi
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2015, 108 (02) : 342 - 349