Evaluation of blood glucose fluctuation in Japanese patients with type 1 diabetes mellitus by self-monitoring of blood glucose and continuous glucose monitoring

被引:14
|
作者
Kusunoki, Yoshiki [1 ]
Katsuno, Tomoyuki [2 ]
Nakae, Rie [1 ]
Watanabe, Kahori [1 ]
Akagami, Takafumi [1 ]
Ochi, Fumihiro [1 ]
Tokuda, Masaru [1 ]
Murai, Kazuki [1 ]
Miuchi, Masayuki [1 ]
Miyagawa, Jun-ichiro [1 ]
Namba, Mitsuyoshi [1 ]
机构
[1] Hyogo Coll Med, Dept Internal Med, Div Diabet Endocrinol & Metab, Nishinomiya, Hyogo 6638501, Japan
[2] Hyogo Coll Med, Div Innovat Diabet Treatment, Nishinomiya, Hyogo 6638501, Japan
关键词
Self-monitoring of blood glucose; Continuous glucose monitoring; Type 1 diabetes mellitus; Glycemic excursion; Hypoglycemia; SEVERE HYPOGLYCEMIA; GLYCEMIC VARIABILITY; OXIDATIVE STRESS; BED SYNDROME; ASSOCIATION; HEMOGLOBIN; EVENTS; ADULTS; INDEX; RISK;
D O I
10.1016/j.diabres.2015.01.040
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: Accurate assessment of blood glucose fluctuation is essential for managing blood glucose control while avoiding hypoglycemia in patients with diabetes mellitus. In this study, blood glucose was measured by continuous glucose monitoring (CGM) in patients with type 1 diabetes mellitus (T1DM) whom self-monitoring of blood glucose (SMBG) was carried out three or more times per day, and evaluation was performed using blood glucose fluctuation parameters obtained by CGM and SMBG. Methods: Twenty-nine insulin-depleted patients with T1DM were enrolled. Their blood glucose fluctuations were measured at the same time by SMBG and CGM, and the correlations were evaluated. Results: Correlations were found between the following values obtained by SMBG and CGM: mean and standard deviation of blood glucose levels, average daily risk range, Morbus value and high-blood-glucose index. The hypoglycemia duration and the nocturnal hypoglycemia duration showed no correlation with any of the blood glucose fluctuation parameters obtained by SMBG. Conclusions: The findings suggest that routine SMBG and glycated hemoglobin (HbA1c) measurement are sufficient for evaluation of hyperglycemia in T1DM. On the other hand, blood glucose fluctuation parameters obtained by SMBG and HbA1c have been shown to have no correlations with either hypoglycemia duration or nocturnal hypoglycemia duration. (C) 2015 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:342 / 349
页数:8
相关论文
共 50 条
  • [1] Comparative Analysis of the Efficacy and Safety of Continuous Glucose Monitoring and Self-Monitoring Blood Glucose in Type 1 Diabetes Mellitus
    Floyd, Baraka D.
    Chandra, Prakash
    Hall, Stephanie P.
    Phillips, Christopher O.
    Alema-Mensah, Ernest
    Strayhorn, Gregory
    Ofili, Elizabeth
    Umpierrez, Guillermo
    [J]. DIABETES, 2010, 59 : A33 - A33
  • [2] Continuous glucose monitoring versus self-monitoring of blood glucose in the treatment of gestational diabetes mellitus
    Kestila, Kirsimarja K.
    Ekblad, Ulla U.
    Ronnemaa, Tapani
    [J]. DIABETES RESEARCH AND CLINICAL PRACTICE, 2007, 77 (02) : 174 - 179
  • [3] Efficacy and safety comparison of continuous glucose monitoring and self-monitoring of blood glucose in type 1 diabetes
    Wojciechowski, Piotr
    Rys, Przemyslaw
    Lipowska, Anna
    Gaweska, Magdalena
    Malecki, Maciej T.
    [J]. POLSKIE ARCHIWUM MEDYCYNY WEWNETRZNEJ-POLISH ARCHIVES OF INTERNAL MEDICINE, 2011, 121 (10): : 333 - 343
  • [4] Self-monitoring of blood glucose and type 2 diabetes mellitus
    Le Devehat, C.
    [J]. DIABETES & METABOLISM, 2006, 32 (02) : 2S17 - 2S20
  • [5] Flash glucose monitoring in type 1 diabetes: A comparison with self-monitoring blood glucose
    Babaya, Naru
    Noso, Shinsuke
    Hiromine, Yoshihisa
    Taketomo, Yasunori
    Niwano, Fumimaru
    Yoshida, Sawa
    Yasutake, Sara
    Kawabata, Yumiko
    Ikegami, Hiroshi
    [J]. JOURNAL OF DIABETES INVESTIGATION, 2020, 11 (05) : 1222 - 1229
  • [6] The value of Continuous Glucose Monitoring and Self-Monitoring of Blood Glucose in patients with Gestational Diabetes Mellitus during Ramadan fasting
    Afandi, Bachar
    Hassanein, Mohamed
    Roubi, Sana
    Nagelkerke, Nico
    [J]. DIABETES RESEARCH AND CLINICAL PRACTICE, 2019, 151 : 260 - 264
  • [7] Self-monitoring of blood glucose in gestational diabetes mellitus
    Fontaine, P
    [J]. DIABETES & METABOLISM, 2003, 29 (02) : S37 - S41
  • [8] Standardization of Self-Monitoring of Blood Glucose and Continuous Glucose Monitoring Reporting
    Garg, Satish K.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 (03) : 193 - 193
  • [9] Compliance with recommended self-monitoring of blood glucose in patients with Type 1 diabetes mellitus.
    Shankar, A
    Conner, MT
    Bodansky, HJ
    [J]. DIABETOLOGIA, 2003, 46 : A90 - A90
  • [10] Self-monitoring of blood glucose in type 2 diabetes
    Lowe, Julia
    [J]. AUSTRALIAN PRESCRIBER, 2010, 33 (05) : 138 - 140