Comparison between a flash glucose monitoring system and a portable blood glucose meter for monitoring dogs with diabetes mellitus

被引:24
|
作者
Del Baldo, Francesca [1 ]
Canton, Claudia [1 ]
Testa, Silvia [1 ]
Swales, Harry [2 ]
Drudi, Ignazio [3 ]
Golinelli, Stefania [1 ]
Fracassi, Federico [1 ]
机构
[1] Univ Bologna, Dept Vet Med Sci, Via Tolara di Sopra 50, I-40064 Bologna, Italy
[2] Univ Liverpool, Small Anim Teaching Hosp, Leahurst Campus, Wirral, Merseyside, England
[3] Univ Bologna, Dept Stat Sci, Bologna, Italy
关键词
canine; diabetes mellitus; FreeStyle Libre; interstitial glucose; TO-DAY VARIATION; GLYCEMIC VARIABILITY; INTERSTITIAL GLUCOSE; SENSING TECHNOLOGY; GROWTH-HORMONE; REAL-LIFE; INSULIN; TYPE-1; HYPOGLYCEMIA; MULTICENTER;
D O I
10.1111/jvim.15930
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background Flash glucose monitoring system (FGMS; FreeStyle Libre) was recently validated for use in diabetic dogs (DD). It is not known if this system is clinically useful in monitoring DD. Objective To compare the clinical utility of FGMS against blood glucose curves (BGCs) obtained with a portable blood glucose meter (PBGM) in monitoring DD. Animals Twenty dogs with diabetes mellitus. Methods Prospective study. Dogs with diabetes mellitus on insulin treatment for at least 1 month were included. Comparisons of insulin dose recommendations based on the in-hospital GCs acquired using FGMS and a PBGM, consecutive-day interstitial GCs (IGCs) acquired at home using the FGMS, and consecutive-day, home vs hospital IGCs acquired using the FGMS were made using concordance analysis. Results There was good concordance between insulin dose recommendations based on FGMS and PBGM generated GCs and IGCs obtained in the 2 different environments on 2 consecutive days, but almost absent concordance between IGCs obtained on 2 consecutive days at home. Glucose nadirs were detected in 34/43 (79%) of Ambulatory Glucose Profile (AGP) reports of the FGMS. In comparison, concordant glucose nadirs were identified in 14/34 (41%) BGCs using PBGM. The individual FGMS scans and PBGM identified 60% and 9% of low IG/hypoglycemic episodes, respectively. Conclusions and Clinical Importance Insulin dose adjustments based on BGCs can be suboptimal. The FGMS allows a more accurate identification of the glucose nadirs and hypoglycemic episodes compared to the use of a PBGM and assessment of day-to-day variations in glycemic control.
引用
收藏
页码:2296 / 2305
页数:10
相关论文
共 50 条
  • [21] Blood glucose monitoring in gestational diabetes mellitus - Reply
    deVeciana, M
    Morgan, MA
    Major, CA
    NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (09): : 599 - 599
  • [22] Clinical Performance of Flash Glucose Monitoring System in Patients with Liver Cirrhosis and Diabetes Mellitus
    Dalila Costa
    Joana Lourenço
    Ana Margarida Monteiro
    Beatriz Castro
    Patricia Oliveira
    Maria Carmo Tinoco
    Vera Fernandes
    Olinda Marques
    Raquel Gonçalves
    Carla Rolanda
    Scientific Reports, 10
  • [23] Clinical Performance of Flash Glucose Monitoring System in Patients with Liver Cirrhosis and Diabetes Mellitus
    Costa, Dalila
    Lourenco, Joana
    Monteiro, Ana Margarida
    Castro, Beatriz
    Oliveira, Patricia
    Tinoco, Maria Carmo
    Fernandes, Vera
    Marques, Olinda
    Goncalves, Raquel
    Rolanda, Carla
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [24] Accuracy of a Flash Glucose monitoring System in Dogs with diabetic Ketoacidosis
    不详
    KLEINTIERPRAXIS, 2021, 66 (06): : 373 - 373
  • [25] Accuracy of a flash glucose monitoring system in dogs with diabetic ketoacidosis
    Malerba, Eleonora
    Cattani, Chiara
    Del Baldo, Francesca
    Carotenuto, Gaia
    Corradini, Sara
    Golinelli, Stefania
    Drudi, Ignazio
    Fracassi, Federico
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2020, 34 (01) : 83 - 91
  • [26] Complications associated with a flash glucose monitoring system in diabetic dogs
    Campbell, Carson
    Shoelson, Adam
    Mahony, Orla
    CANADIAN JOURNAL OF VETERINARY RESEARCH-REVUE CANADIENNE DE RECHERCHE VETERINAIRE, 2023, 87 (04): : 260 - 264
  • [27] A new glucose monitoring system for the intermittent monitoring of interstitial glucose values in patients with diabetes mellitus
    Rossi, Antonio
    Rossi, Giada
    Montefusco, Laura
    Cimino, Vincenzo
    Pastore, Ida
    Gandolfi, Alessandra
    Bucciarelli, Loredana
    Loretelli, Cristian
    Boci, Denisa
    D'Addio, Francesca
    Lunati, Maria Elena
    Fiorina, Paolo
    JOURNAL OF DIABETES AND METABOLIC DISORDERS, 2024, : 2201 - 2205
  • [28] Evaluation of a flash glucose monitoring system in dogs with diabetic ketoacidosis
    Silva, D. D.
    Cecci, G. R. M.
    Biz, G.
    Chiaro, F. N.
    Zanutto, M. S.
    DOMESTIC ANIMAL ENDOCRINOLOGY, 2021, 74
  • [29] Continuous glucose monitoring versus self-monitoring of blood glucose in the treatment of gestational diabetes mellitus
    Kestila, Kirsimarja K.
    Ekblad, Ulla U.
    Ronnemaa, Tapani
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2007, 77 (02) : 174 - 179
  • [30] Accuracy of Flash Glucose Monitoring in Hemodialysis Patients With and Without Diabetes Mellitus
    Weber, Michele R.
    Diebold, Matthias
    Wiesli, Peter
    Kistler, Andreas D.