Reconstruction of the gland sealing system of a 300MW steam turbine unit

被引:0
|
作者
Xie, DM [1 ]
Liu, GL [1 ]
Wang, JM [1 ]
Yang, J [1 ]
机构
[1] Wuhan Univ, Power Engn Dept, Wuhan 430072, Hubei, Peoples R China
关键词
reconstruction; gland sealing system; steam leakage;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper discusses the steam leakage of a 300MW steam turbine unit and its effect on the turbine's economy and efficiency by calculation in details. Then it introduces the measures used to deal with this problem at site.
引用
收藏
页码:862 / 866
页数:5
相关论文
共 50 条
  • [1] Assessing the flaws in welded seam of header of a 300MW steam turbine generator unit
    Song, Li
    Yang, Shuicheng
    Wei, Fengtao
    [J]. ENGINEERING PLASTICITY AND ITS APPLICATIONS FROM NANOSCALE TO MACROSCALE, PTS 1 AND 2, 2007, 340-341 : 1431 - +
  • [2] Economics Analysis of Retrofit of Flow Passage of a 300MW Steam Turbine
    Shi Yang
    Li Wan-Fan
    Xie Dan-mei
    Tan Cheng-cheng
    Feng Ming
    Cai Sun
    [J]. 2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [3] IP Start-up Control for 300MW Turbine Unit with Bypass System
    Wang, Weibing
    Wang, Xudong
    Liu, Dongju
    [J]. INTERNATIONAL WORKSHOP ON AUTOMOBILE, POWER AND ENERGY ENGINEERING, 2011, 16
  • [4] On effective rapid startup of 300 MW steam turbine unit
    Dong, Chao
    Wang, Bin
    Sun, Yongjian
    Wang, Xiaohong
    [J]. PROCEEDINGS OF THE 32ND 2020 CHINESE CONTROL AND DECISION CONFERENCE (CCDC 2020), 2020, : 803 - 808
  • [5] Theoretical analysis on the erosion of the low pressure stage blades for a 300MW steam turbine
    Li, N
    Li, Y
    [J]. CASE HISTORIES ON INTEGRITY AND FAILURES IN INDUSTRY, 1999, : 803 - 810
  • [6] NUMERICAL STUDY ON CONDENSING FLOW IN LOW PRESSURE CYLINDER OF A 300MW STEAM TURBINE
    Li, Liang
    Li, Yu
    Wu, Lianwei
    You, Wei
    Li, Jun
    Feng, Zhenping
    [J]. PROCEEDINGS OF THE ASME TURBO EXPO 2010: TURBOMACHINERY: AXIAL FLOW FAN AND COMPRESSOR AERODYNAMICS DESIGN METHODS, AND CFD MODELING FOR TURBOMACHINERY, VOL 7, PTS A-C, 2010, : 2289 - 2296
  • [7] Neurofuzzy network modelling and control of steam pressure in 300MW steam-boiler system
    Liu, XJ
    Lara-Rosano, F
    [J]. PROCEEDINGS OF THE 2003 AMERICAN CONTROL CONFERENCE, VOLS 1-6, 2003, : 2282 - 2287
  • [8] Assessment of 300MW Turbine Generator Stator Insulation
    Wang, Lijun
    Zhang, Yizhong
    Jin, Wenjing
    Shi, Jingzhe
    Zhou, Song
    Li, Qiang
    Liu, Song
    [J]. PROCEEDINGS OF 2014 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM 2014), 2014, : 500 - 502
  • [9] Superheater Steam Temperature Control for a 300MW Boiler Unit with Inverse Dynamic Process Models
    Ma, Liangyu
    Lin, Yongjun
    Lee, Kwang Y.
    [J]. IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [10] The Thermal Stress of a Domestic 300MW Steam Turbo Unit During Its Startup and Shutdown
    Wang, Haitao
    Xia, Yunchun
    [J]. APPLIED MECHANICS AND MATERIALS I, PTS 1-3, 2013, 275-277 : 87 - +